Heat Exchanger
Calculates gas-side pressure drop, outlet temperature, and heat duty using external temperature and conductance, or specified heat flux.
Component Appearance and Location
Expand Heat Exchange Treatment in the component library on the left and find "Heat Exchanger".
Ports and Connections
| Port Key | Type | Direction | Interface Name | Display Conditions |
|---|---|---|---|---|
0 | FLUID | input | fluid inlet | always show |
1 | FLUID | output | Fluid outlet | always show |
Connect in the main flow direction. Port 0 is upstream for forward flow; 1 for reverse flow. Bind measurements and commands with a measurement instrument or actuator.
Parameter List
Equipment Specifications
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Flow Coefficient Kv [m³/(h·bar⁰ᐧ⁵)] | FullOpenKV | real | 5000 | Gas-side pressure-drop coefficient from equipment resistance data. Larger Kv gives less drop at equal flow/state. |
| Effective Heat Transfer Area [m²] | HeatTransferArea | real | 10 | Effective area for heat transfer, sharing coefficient/flux area basis; use equipment data. |
Control Mode
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Heat Transfer Mode | HeatExchangeMode | choice | External Temperature and Overall Coefficient / Specified Heat Flux | Determine duty from external temperature/coefficient/area, or specified heat flux/area. |
| Control Source | ControlMode | choice | 0 | Plans/signals apply only in transients. Steady-state uses initial/static physical parameters, retaining saved source/wiring. |
Heat Transfer Parameters
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Overall Coefficient Source | HeatTransferCoefficientInputMode | choice | Fixed Value / Time Curve | Fixed or time-varying overall coefficient. |
| Overall Heat Transfer Coefficient [W/(m²·K)] | HeatTransferCoefficient | real | 50 | Overall gas/external-medium coefficient on the effective area basis; zero means adiabatic. |
| Overall Heat Transfer Coefficient Curve | CurveLibraryHeatTransferCoefficientName | choice | __UNSELECTED__ | Select an overall heat transfer coefficient curve whose area basis matches this component's heat transfer area. |
| External Fluid Temperature Source | ExternalTemperatureInputMode | choice | Fixed Value / Time Curve / Temperature Signal | Fixed, curve, or temperature signal; signal mode needs external-temperature actuation adapter. |
| External Fluid Temperature [℃] | ExternalTemperature | real | 10 | External heating/cooling medium temperature sets thermal driving difference/direction. |
| External Fluid Temperature Curve | CurveLibraryTemperatureName | choice | __UNSELECTED__ | Select an external fluid temperature curve. A steady-state run uses its value at the simulation start time. |
| Heat Flux Source | HeatFluxInputMode | choice | Fixed Value / Time Curve / Heat Flux Signal | Fixed, curve, or heat-flux signal. Signal mode needs heat-flux adapter; legacy heat-duty signals still use heat-duty adapters. |
| Heat Flux [W/m²] | HeatFlux | real | 0 | Power per effective area, positive heating/negative cooling. Times area gives requested duty, limited by capacity; actual duty is zero without flow. |
| Heat Flux Curve | CurveLibraryHeatFluxName | choice | __UNSELECTED__ | Select a heat flux curve. Positive values heat the gas and negative values remove heat. The solver calculates the heat load using this component's heat transfer area. |
| Thermal Conductance UA [W/K] | UA | real | 500 | Overall coefficient × area. |
| External Fluid Temperature [℃] | ColdSideTemperature | real | 10 | Cooling/heating medium temperature. |
Operating Constraints
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Maximum Heating Duty [kW] | MaximumHeatingDuty | real | 1000 | Equipment duty limit for specified heat flux/duty. |
| Maximum Cooling Duty [kW] | MaximumCoolingDuty | real | 1000 | Equipment duty limit for specified heat flux/duty. |
Transient Events
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Event Chain | Events | table | Configure one row at a time | External-temperature events with linear interpolation between rows. |
| Event Chain / Time | Events.time | datetime | 2026-01-01 00:00:00 | Time |
| Event Chain / External Fluid Temperature [℃] | Events.coldSideTemperature | real | 10 | External cooling/heating temperature at this time. |
Parameter Guidance
Set Kv from gas-side pressure-drop data. Effective area must share the basis used for overall coefficient or heat flux.
| Mode | Use | Transient input |
|---|---|---|
| External temperature and overall coefficient | Known external temperature and conductance; gas state and flow determine duty | U in W/(m²·K): fixed or time curve. External °C: also temperature signal. |
| Specified heat flux | Known heating/cooling per unit area | W/m²: fixed, time curve, or signal. Heating/cooling limits: separate nonnegative kW values. |
Steady-state calculations use the current panel values. Control signals apply during transients. Time curves are interpolated linearly at the end of each transient step and at the calculation start for the initial state.
Enter Curves
Set the relevant input to Time Curve, then select its Curve Source. Configure curves for overall heat transfer coefficient, external temperature, and heat flux separately. The calculation uses the inputs for the selected heat transfer mode.
| Curve | Local points | Database source | Units |
|---|---|---|---|
| Overall heat transfer coefficient | Time and overall heat transfer coefficient | Overall heat transfer coefficient curve | W/(m²·K) |
| External temperature | Time and external medium temperature | Temperature curve | °C |
| Heat flux | Time and heat flux | Heat flux curve | W/m², positive for heating and negative for cooling |
Use Edit Local Curve to enter points on the component or Reference Curve Database to select a named curve of the same type. Time must increase strictly and cover the calculation interval. Heat flux times effective transfer area gives the requested heat duty. Area times coefficient gives thermal conductance . Choose a curve source.
Modeling Steps
- Connect gas ports in main direction.
- Enter Kv.
- For non-isothermal mode, select thermal mode and area.
- In external-temperature mode, choose the sources for overall coefficient and external medium temperature. In specified-heat-flux mode, choose the heat flux source. For each time curve, enter local points or select a database curve.
- Bind actuators for signal inputs; set heating/cooling limits for specified flux.
- Add measurement instruments if needed.
- Check drop, heat direction, temperatures, and actual duty.
View Results
- Ports. Determine actual upstream by flow sign before comparing state.
- Temperature/coefficient mode. Compare external temperature, coefficient, and actual duty.
- Flux mode. Compare requested, adopted, and actual duty: input request, limited/zero-flow-adjusted solve input, and duty from gas states. Energy residual is actual minus adopted. Duty uses kW; flux W/m².
Professional Theory
Gas-Side Pressure Drop and Mass Conservation
Let be absolute pressures in Pa and actual volume flows in m³/s, positive 0→1. There is no gas inventory; mass is conserved in steady-state and transients. Resistance is quadratic in Kv with near-zero smoothing.
are port densities and actual upstream density in kg/m³. The drop formula always uses port-0 ; reverse flow uses port-1 density. Larger Kv gives smaller drop for fixed flow/state. Kv, area, and coefficient are independent inputs.
External Temperature and Overall Coefficient
Subscripts mean actual upstream/downstream. Temperature uses K; is kg/s. Composition passes with flow. Specific enthalpy uses J/kg and incoming composition . Actual heat duty in W follows enthalpy difference.
External fluid is a source/sink at given . Area in m² and coefficient give in W/K. Upstream determines NTU. Let weight incoming enthalpy:
Invert at outlet pressure for temperature. Higher conductance approaches external temperature. At fixed and heat capacity, higher mass flow gives lower NTU and smaller enthalpy change per mass.
For negligible pressure drop and constant heat capacity, and . ASHRAE Effectiveness and NTU
Specified Heat Flux
Flux in W/m² times area gives requested duty. With flow, heating/cooling limits determine adopted duty. Formulas use W; panel limits use kW.
Maximum cooling duty is its absolute capacity. Positive duty raises enthalpy, negative lowers it, independent of flow direction. Temperature change also depends on pressures and properties. At equal duty, lower flow gives larger specific enthalpy change.
Zero Heat Transfer and Zero Flow
With flow, or zero adopted duty gives ; pressure drop can still cause throttling temperature change. With zero flow, no cross-port transport occurs and adopted/actual duty are zero. Flux mode retains requested duty and recalculates from current input/limits when flow resumes.
Applicability and Limits
- One-sided lumped transfer. External conditions are imposed; use a two-fluid model to solve both streams.
- No thermal storage. Duty uses current boundary/state; wall and body inertia are outside scope.
- Global thermal mode. Isothermal mode retains hydraulic resistance; temperature changes and duty require non-isothermal mode.
Common Inspections
- Unexpected drop. Check Kv and actual upstream density; convert port-0 flow to m³/s.
- Unexpected temperature/direction. Identify upstream, then check external temperature, UA, area basis, and flow. Duty follows enthalpy change; check drop for zero-duty temperature differences.
- Actual differs from request. Compare requested/adopted/actual duty, limits, and zero-flow restriction; check kW versus W/m².
- Inactive curve/signal. Check non-isothermal mode, curve name/type/coverage, adapter target, signal, and units.