Skip to main content

NexusFlow Gas Network Simulation

NexusFlow gas network simulation analyzes natural gas transmission, regional distribution, urban gas supply, and gas storage and peak shaving systems. Define gas sources, consumer loads, pipelines, and equipment operating conditions to calculate network pressure, flow, temperature, inventory, and equipment states.

First select the simulation type in Simulation Scheme. Steady-state simulation analyzes network balance at a given operating condition; transient simulation analyzes the response to changes in loads, boundaries, or equipment states. Then select an isothermal or non-isothermal model as required. For multiple gas sources, you can also analyze mixing and species transport.

Platform and specialist guides

This guide covers gas network modeling, component models, simulation settings, and result interpretation. For login, model management, general canvas operations, job management, and shared result tools, see the Platform User Guide and NexusFlow Platform Overview.

Supported Networks​

Gas network simulation covers long-distance transmission, regional transmission and distribution, and urban gas supply. Equipment and operating objectives vary, but each network requires defined boundary conditions to calculate pressure, flow, temperature, inventory, and equipment states.

Network typeTypical facilitiesMain analysis tasks
Natural gas transmission trunk linesGas sources, transmission pipelines, compressor stations, valve stations, offtakes, and terminal stationsPressure profiles, transmission capacity, compressor operation, linepack, and load changes
Regional transmission networksMultiple gas sources, trunk and branch lines, interconnections, regulators, and regional consumersGas source allocation, flow reversals, supply and demand balance, and dispatch comparisons
Urban gas networksCity gate stations, sub-high-pressure and medium-pressure pipelines, regulators, valves, and consumer loadsDelivery pressure, regional flow distribution, peak supply, maintenance, and outage impacts
Storage and peak shaving systemsStorage facilities, buffer facilities, compressors, and connecting pipelinesInjection and withdrawal, inventory changes, linepack utilization, and peak shaving capacity
Stations and control systemsCompressors, regulators, shut-off valves, measurement components, and controllersEquipment states, setpoint changes, interlocks, and control processes

Available gases and property calculations depend on the equations of state, gas libraries, and component models provided by the current gas network workspace.

Core Simulation Capabilities​

CapabilityAnalysis tasksTypical results
Steady-state simulationNetwork balance, transmission capacity, and linepack at stable operating conditionsPressure, flow, flow direction, pressure drop, steady-state linepack, and equipment states
Transient simulationNetwork response over time to boundary, load, or equipment changesPressure, flow, temperature, and inventory trends
Non-isothermal calculationPipeline heat transfer, gas compression and expansion, and equipment thermal processesTemperature profiles, equipment inlet and outlet temperatures, and heat duty
Multiple gas sources and species transportTransport and mixing of gas from different sourcesSource contribution fractions, gas composition, and transport behavior
Equipment and control simulationCompression, pressure regulation, valves, storage, and control loopsPressure ratio, power, opening, inventory, and control error

Choose the simulation type and physical model to match the analysis objective, operating changes, and available data.

Engineering Applications​

Operating State and Transmission Capacity​

For specified sources, consumer loads, and equipment states, calculate node and equipment inlet and outlet pressures, pipeline and equipment flow rates, actual flow directions, pressure and temperature profiles, pipeline and storage inventories, and compressor and regulator operating states.

Vary supply pressure, source flow, and demand to assess transmission capacity, check delivery and critical-node pressures, identify limiting pipelines or equipment, and study peak demand and load growth. Model results can supplement operating analysis for pipeline sections without direct measurements between monitoring points.

Multiple Gas Sources and Dispatch Comparisons​

Adjust source pressures, supply rates, or combinations of active sources, together with compressor, regulator, and major consumer operating conditions. Compare pressure, flow, flow direction, linepack, and source contributions across scenarios to support supply and dispatch planning.

Linepack, Storage, and Peak Shaving​

Calculate pipeline, network, and storage inventory at different pressures and loads to assess buffering during peak demand. With suitable data, transient simulation can track pressure, flow, and inventory during load increases, supply changes, and storage injection or withdrawal.

Compressors, Regulators, and Valves​

Simulate compression and operation of multiple units, regulator outlet pressure settings, valve opening and closing, equipment bypass or shutdown, and controller adjustments to setpoints and actuators.

Assess equipment in its actual operating mode using inlet and outlet pressure, flow, pressure ratio, power, opening, and effects on the surrounding network.

Operating Changes, Maintenance, and Abnormal Conditions​

Before an operation or modification, model pipeline shutdown, valve isolation, compressor or regulator withdrawal, interconnection commissioning, new supply or consumer connections, and diameter changes. Compare pressure, flow, supply capacity, and affected areas before and after the change.

For hypothetical supply reductions or interruptions, critical pipeline outages, demand surges, and local equipment faults, assess pressure changes, remaining supply capacity, and affected areas. Compare responses such as source switching, demand adjustment, and valve operations.

Planning Checks, Model Reuse, and Training​

Models calibrated against actual data can support preliminary checks of new supplies, interconnections, diameter changes, and load growth. Retain models, data descriptions, and representative operating cases for operational reviews, technical discussions, and training.

Engineering Workflow​

Engineering simulation usually follows this sequence:

Define the analysis objective
→ Prepare and verify network and operating data
→ Build and check the baseline model
→ Define operating, dispatch, or abnormal scenarios
→ Run steady-state or transient calculations
→ Check conservation, boundaries, and equipment states
→ Compare scenarios and draw engineering conclusions

Required Data​

Prepare and verify the following data for the modeling scope:

  • Network topology, facility connections, and pipeline properties.
  • Valve, regulator, compressor, and storage parameters and operating states.
  • Supply pressure, flow, temperature, and gas composition.
  • Consumer, station, or regional demand.
  • Measured pressure and flow, with timestamps for the operating data.

Required data accuracy depends on the task. Learning examples can use explicitly specified boundaries and parameters; models used for actual operating analysis require data verification and calibration.

Interpreting Results​

A successful solver run is only one part of result credibility. Check that:

  • Topology, equipment states, and boundaries represent the system being analyzed.
  • Pipeline, equipment, and boundary data have clear sources and consistent time bases.
  • Pressure, flow, temperature, and inventory use consistent units and reference conditions.
  • Estimated or allocated loads are checked during calibration.
  • Uncalibrated models are used for learning and trend studies, rather than as direct representations of a particular engineering network.
  • Boundaries, network conservation, equipment states, and result magnitudes remain reasonable after completion.
GoalRecommended reading
First useOpen the Gas Network Workspace → Configure Gas and Global Settings → Build a Single-Pipeline Steady-State Model → Run and View Results
Build a feedback loopBuild a Gas Network Control System → Wire the pressure loop and inspect the transient response
Modeling fundamentalsGas and Reference Conditions, Simulation Scheme
Component parameters and modelsComponent Reference → Ports, parameter lists, parameter selection, and result interpretation on each component page
AI-assisted checksPlatform AI Assistant Guide → AI-Assisted Modeling and Simulation
Engineering applicationsReference Examples → Modeling, results, and engineering interpretation for the relevant scenario

On first use, follow this sequence to complete a minimal steady-state network, then study transmission pipelines, compression and regulation, storage, and transient processes as needed.

For pressure regulation, start with the Regulator Valve and City Gate Pressure Regulation. For overpressure relief, use the Single-Port Relief Valve when discharge backpressure is specified, or the Two-Port Relief Valve when the discharge network must be solved together with the system.