Skip to main content

Build a Single-Pipeline Steady-State Gas Model

Start from a blank canvas and build a single-pipeline system consisting of a gas source, transmission pipeline, and downstream demand boundary. Configure, validate, and save the model before submitting it on the next page.

Goals​

  • Create a connected fluid network: gas field source → transmission pipeline → city gate station.
  • Set upstream and downstream pressure boundaries and pipeline specifications.
  • Check connections, gas data, units, and boundaries before calculation.

Completed Model​

100 km single-pipeline steady-state gas transmission model
100 km single-pipeline steady-state gas transmission model

Gas flows from the gas field through the transmission pipeline to the downstream city gate. Both ends use pressure boundaries; the platform calculates flow from the pressure difference, gas properties, and pipeline parameters.

Example Parameters​

ObjectParameterValue
GlobalSimulation typeSteady-state
GlobalThermal modelIsothermal
GlobalIsothermal temperature20 °C
GlobalGas equation of stateBWRS
GlobalStandard pressure101.325 kPa(a)
GlobalStandard temperature20 °C
GlobalGauge reference pressure101.325 kPa(a)
Gas field sourceInitial supply gasNaturalGas
Gas field sourceBoundary typePressure
Gas field sourceBoundary pressure6 MPa(g)
Transmission pipelineInternal diameter600 mm
Transmission pipelineLength100 km
Transmission pipelineWall thickness10 mm
Transmission pipelineInternal roughness0.025 mm
Transmission pipelineFriction modelColebrook
Transmission pipelineColebrook calculationExplicit approximation
Transmission pipelinePipeline efficiency factor1
Transmission pipelineAxial meshUser-specified
Transmission pipelineAxial cells10
City gateBoundary typePressure
City gateBoundary pressure3 MPa(g)

Step 1: Create the Model and Set Global Parameters​

  1. Open the gas network workspace, click New/Open, and create a blank model.
  2. Click a blank canvas area to display global settings in the right-hand Parameters panel.
  3. Expand Simulation Scheme. Select steady-state simulation, an isothermal model, 20 °C, and BWRS.
  4. Expand Gas Library and click Edit Data beside the Component Gas Library. Add or check NaturalGas: CH₄ 90%, C₂H₆ 5%, C₃H₈ 2%, N₂ 2%, and CO₂ 1%, by mole percentage. If an existing gas of that name has a different composition, create a new name and select it in Step 4.
  5. Under Reference Conditions, set standard pressure and gauge reference pressure to 101.325 kPa(a), and standard temperature to 20 °C.

See Configure Gas and Global Settings for the interface and parameter meanings.

Step 2: Place Components​

  1. Drag a Source and a Load from Boundaries in the library.
  2. Drag a Transmission Pipeline from Pipes and Valves.
  3. Arrange them left to right: source → transmission pipeline → load.
  4. Select each and change its component label to Gas Field Source (6 MPag), 100 km Transmission Pipeline (DN600), and City Gate Station (3 MPag).

This arrangement makes the expected flow direction and subsequent pipeline profile results easy to follow.

Step 3: Connect Fluid Ports​

  1. Connect the source fluid outlet to the pipeline inlet.
  2. Connect the pipeline outlet to the load fluid inlet.
  3. Check that both connections are attached to fluid ports and no component is isolated.

Step 4: Configure the Gas Field Source​

Select the source and expand Medium and Initial Conditions in the parameter panel. Select the gas entered or checked in Step 1, choose a pressure boundary, and set 6 MPa(g).

Initial supply gas and pressure boundary for the gas field source
Initial supply gas and pressure boundary for the gas field source

MPa(g) and MPag both denote gauge pressure. The platform converts it to absolute pressure using the global gauge reference pressure.

Step 5: Configure the Transmission Pipeline​

  1. Select the pipeline, expand Equipment Specifications, and enter geometry and friction parameters from the example table.
  2. Expand Advanced Settings, set Axial Mesh to User-specified, and enter 10 axial cells to divide the pipeline into 10 uniform calculation cells.
Transmission pipeline specifications and axial mesh
Transmission pipeline specifications and axial mesh

The example uses an isothermal model and the default level elevation profile. See Transmission Pipeline for complete parameters.

Step 6: Configure the City Gate Boundary​

Select the city gate, expand Boundary Conditions, choose a pressure boundary, and enter 3 MPa(g).

City gate pressure boundary
City gate pressure boundary

The load represents the downstream pressure boundary at the city gate.

Step 7: Validate and Save the Model​

Check the two fluid connections, source gas selection, boundary pressures, pipeline specifications, axial mesh, and global scheme against the parameter table.

Click Logs at the bottom left of the canvas, then Validate Simulation Model in the log panel. Correct reported errors and validate again. Once validation passes, click Save in the top toolbar.

Validate the simulation model in the log panel
Validate the simulation model in the log panel

Next Step​