Build a Single-Pipeline Steady-State Model with AI
Starting with an empty canvas, use the AI assistant to build a gas field source → 100 km transmission pipeline → city gate model.
Ask AI to read the draft and propose a plan first, then approve modeling. Afterward, check the parameters it reads back and manually validate and save the model.
Prepare an Empty Model and Enable AI Control
- Create an empty gas network model and click AI Control at the bottom (1 in the image).
- Under Current Authorization, select only Read, Results and Screenshots, then turn on AI Control (2).

- Click Intelligent Assistant at the bottom. In the NexusFlow assistant input area, select Use the Currently Authorized Workbench.

Enter Complete Modeling Requirements
Copy the complete prompt below into the assistant input area shown in the image.

Plan a single-pipeline steady-state gas transmission model for the current blank model.
At this stage, only read the draft and list the plan; wait for my confirmation.
Requirements
1. Set the global simulation type to steady-state.
2. Select an isothermal model at 20 °C.
3. Use BWRS; set standard pressure and gauge reference pressure to 101.325 kPa(a), and standard temperature to 20 °C.
4. Place a source, transmission pipeline, and load from left to right.
5. Label them Gas Field Source (6 MPag), 100 km Transmission Pipeline (DN600), and City Gate Station (3 MPag).
6. Connect the source fluid outlet to the pipeline inlet, then the pipeline outlet to the load fluid inlet.
7. Use NaturalGas in the Component Gas Library: CH4 90%, C2H6 5%, C3H8 2%, N2 2%, CO2 1%, by mole percentage. Check for an existing gas of that name. If missing, plan to add it; if its composition differs, plan to add this composition under a new name. Reference this gas as the source's initial supply gas.
8. Use pressure boundaries of 6 MPa(g) at the source and 3 MPa(g) at the city gate.
9. Set pipeline internal diameter to 600 mm, length to 100 km, wall thickness to 10 mm, and roughness to 0.025 mm. Use the Colebrook explicit approximation, efficiency factor 1, the default level elevation profile, and a user-specified axial mesh of 10 cells.
10. Arrange the three components neatly in a horizontal line with flow from left to right.
List planned operations, components, connections, and parameters, and identify anything requiring confirmation. I will manually validate, save, and submit the model.
Review the AI Plan
Check global parameters, components, and connections. The sample response below asks whether to add NaturalGas composition or use methane: choose the five specified species. If the plan includes platform validation or solving, ask AI to leave those steps to you.

Before approval, check that:
- The target is the current blank model.
- It creates one source, one transmission pipeline, one load, and two correctly directed fluid connections.
- Composition, boundary pressures, diameter, length, and roughness match the prompt, with a user-specified mesh of 10 cells.
After confirming the plan, turn AI Control off. Keep Read, Results and Screenshots, add Edit Current Draft, then turn AI Control on again. Leave Validate and Start Calculation and Job Control and Commands unchecked. Return to the assistant, confirm it still uses the currently authorized workbench, and send:
Execute the checked modeling plan. Edit only the current draft. Set the gas composition to the five mole percentages above and reference that entry from the source.
Report the components, connections, and parameters actually created, and any unfinished operations.
I will manually validate, save, and submit the model.
Inspect the Actual Model
Compare components and connections with the image, then check the actual parameters against the table.

| Check | Expected configuration |
|---|---|
| Global scheme | Steady-state, isothermal, 20 °C, BWRS |
| Reference conditions | Standard pressure 101.325 kPa(a), standard temperature 20 °C, gauge reference pressure 101.325 kPa(a) |
| Gas | Source references CH4 90%, C2H6 5%, C3H8 2%, N2 2%, CO2 1% |
| Components | Gas field source, 100 km pipeline, city gate; 3 components |
| Fluid connections | Source outlet → pipeline inlet; pipeline outlet → city gate inlet; 2 connections |
| Boundaries | Source 6 MPa(g), city gate 3 MPa(g), both pressure boundaries |
| Pipeline | Diameter 600 mm, length 100 km, wall 10 mm, roughness 0.025 mm, Colebrook explicit approximation, efficiency 1, user-specified 10-cell axial mesh |
Ask AI to Read Back and Check the Model
After modeling, ask AI to read the draft and report actual values:
Only read and check the current model.
Briefly summarize the global scheme, reference conditions, gas composition,
the three components and two connections, both pressure boundaries,
pipeline length and units, axial mesh mode and cell count, and other specifications.
The readback should match the table. If counts, directions, or values differ, identify the object and target value, request a correction plan, and approve it before editing.
Follow-Up Operations
Turn AI Control off. Manually validate and save the model, submit a job, then follow Run and View Results to check job status, pressure profiles, and inlet and outlet standard volume flow.