Run Calculations and View Results
Use the gas field source → 100 km transmission pipeline → city gate model from Build a Single-Pipeline Steady-State Gas Model to submit a calculation, confirm completion, and interpret the pressure profile.
Start the Calculation
Open the validated and saved model and click Start Calculation in the top toolbar.

The platform checks the model and creates a calculation job. To change operating conditions, return to Model, edit and save, then submit a new job.
Confirm Completion
Open Jobs on the left and select the submitted job. After it succeeds, inspect results on that job's canvas. The example shows success and 100% progress.

| Status | Meaning | Action |
|---|---|---|
| Waiting or progress not started | Waiting for resources or initializing | Wait for updates; avoid duplicate submissions. |
| Running with increasing progress | Steady-state initialization and iteration | Open logs to check the current stage. |
success, 100% | Calculation completed | Check boundaries, pressure profiles, flow, and conservation. |
| Failed or ended early | Calculation did not complete normally | Find the earliest error in this job's log and check the corresponding component and parameters. |
Monitor Key Results with a Data Block
After success, create a data block on the job canvas to view pressures at both ends, pressure drop, and standard volume flow.
- Select 100 km Transmission Pipeline (DN600).
- Right-click it and select Create Data Block.
- Locate inlet and outlet pressures and pressure drop, then compare the inlet and outlet flows in
Nm³/h.

Compare the absolute standard volume flow rates at both ends to check steady-state continuity. They use the same standard pressure and temperature. Actual volume flow varies along the pipeline because gas density changes with position.
View the Pipeline Pressure Profile
- Select 100 km Transmission Pipeline (DN600) on the canvas.
- Click Trend Chart below the canvas.
- Select Pressure Profile in the result window.
- Check that the horizontal axis covers 0–100 km. The vertical axis uses MPag (gauge pressure). The curve should start at 6 MPa(g) and end at 3 MPa(g).

Pressure decreases continuously in the flow direction, with a steeper gradient near the outlet.
Key Results
| Check | Reference value | Where to find it |
|---|---|---|
| Inlet pressure | 6 MPa(g), matching the gas field source | Data block inlet pressure or pressure profile start. |
| Outlet pressure | 3 MPa(g), matching the city gate | Data block outlet pressure or pressure profile end. |
| Pressure drop | 3,000 kPa | Pipeline data block. |
| Inlet and outlet standard volume flow | Approximately 492,871 Nm³/h in absolute value at both ends | Data block flow results in Nm³/h. |
Both end pressures are inputs; the solver calculates transmission flow. Changing composition, reference conditions, diameter, roughness, or downstream pressure changes that flow.
Check Result Plausibility
Check boundary pressures and pressure drop against the table, confirm that pressure decreases from the gas field to the city gate, and compare absolute standard volume flow at both ends for steady-state continuity.
Logs and Other Results
Select the job and click Logs below the canvas to inspect initialization, steady-state solving, warnings, and errors. On failure, find the earliest error and check the affected component and parameters.
Use Other Results for solver residuals and diagnostics. Residuals indicate numerical convergence; engineering checks of pressure, flow, and pressure drop are still required.
Common Questions
| Symptom | Check or action |
|---|---|
| Normal solving does not start | Check disconnected ports, isolated components, invalid gas selections, and missing pressure boundaries. |
| Failure cause is unclear | Find the earliest log error and check component parameters and units. |
| Trend chart asks for a valid component | Select the pipeline on the job canvas before opening the chart. |
| Pressure profile is nearly flat | Check the selected job and component, length, boundary pressures, and vertical axis range. |
| Profile does not cover 100 km | Check the component, axis units, and model pipeline length. |
| Results do not change after editing | Submit a new job and make sure you are viewing it rather than a historical job. |
| Flow sign differs from expectations | Interpret signs using port directions; compare absolute standard volume flow for continuity in this example. |
Next Step
See Transmission Pipeline for friction, discretization, elevation, and external heat transfer, or AI-Assisted Modeling and Simulation for checks of model connections, job logs, and key results.