Skip to main content

Run Calculations and View Results

Use the gas field source → 100 km transmission pipeline → city gate model from Build a Single-Pipeline Steady-State Gas Model to submit a calculation, confirm completion, and interpret the pressure profile.

Start the Calculation​

Open the validated and saved model and click Start Calculation in the top toolbar.

Start Calculation in the toolbar
Start Calculation in the toolbar

The platform checks the model and creates a calculation job. To change operating conditions, return to Model, edit and save, then submit a new job.

Confirm Completion​

Open Jobs on the left and select the submitted job. After it succeeds, inspect results on that job's canvas. The example shows success and 100% progress.

Successful steady-state pipeline job
Successful steady-state pipeline job
StatusMeaningAction
Waiting or progress not startedWaiting for resources or initializingWait for updates; avoid duplicate submissions.
Running with increasing progressSteady-state initialization and iterationOpen logs to check the current stage.
success, 100%Calculation completedCheck boundaries, pressure profiles, flow, and conservation.
Failed or ended earlyCalculation did not complete normallyFind the earliest error in this job's log and check the corresponding component and parameters.

Monitor Key Results with a Data Block​

After success, create a data block on the job canvas to view pressures at both ends, pressure drop, and standard volume flow.

  1. Select 100 km Transmission Pipeline (DN600).
  2. Right-click it and select Create Data Block.
  3. Locate inlet and outlet pressures and pressure drop, then compare the inlet and outlet flows in Nm³/h.
Create a pipeline data block from the context menu
Create a pipeline data block from the context menu

Compare the absolute standard volume flow rates at both ends to check steady-state continuity. They use the same standard pressure and temperature. Actual volume flow varies along the pipeline because gas density changes with position.

View the Pipeline Pressure Profile​

  1. Select 100 km Transmission Pipeline (DN600) on the canvas.
  2. Click Trend Chart below the canvas.
  3. Select Pressure Profile in the result window.
  4. Check that the horizontal axis covers 0–100 km. The vertical axis uses MPag (gauge pressure). The curve should start at 6 MPa(g) and end at 3 MPa(g).
Pressure profile along the 100 km pipeline
Pressure profile along the 100 km pipeline

Pressure decreases continuously in the flow direction, with a steeper gradient near the outlet.

Key Results​

CheckReference valueWhere to find it
Inlet pressure6 MPa(g), matching the gas field sourceData block inlet pressure or pressure profile start.
Outlet pressure3 MPa(g), matching the city gateData block outlet pressure or pressure profile end.
Pressure drop3,000 kPaPipeline data block.
Inlet and outlet standard volume flowApproximately 492,871 Nm³/h in absolute value at both endsData block flow results in Nm³/h.

Both end pressures are inputs; the solver calculates transmission flow. Changing composition, reference conditions, diameter, roughness, or downstream pressure changes that flow.

Check Result Plausibility​

Check boundary pressures and pressure drop against the table, confirm that pressure decreases from the gas field to the city gate, and compare absolute standard volume flow at both ends for steady-state continuity.

Logs and Other Results​

Select the job and click Logs below the canvas to inspect initialization, steady-state solving, warnings, and errors. On failure, find the earliest error and check the affected component and parameters.

Use Other Results for solver residuals and diagnostics. Residuals indicate numerical convergence; engineering checks of pressure, flow, and pressure drop are still required.

Common Questions​

SymptomCheck or action
Normal solving does not startCheck disconnected ports, isolated components, invalid gas selections, and missing pressure boundaries.
Failure cause is unclearFind the earliest log error and check component parameters and units.
Trend chart asks for a valid componentSelect the pipeline on the job canvas before opening the chart.
Pressure profile is nearly flatCheck the selected job and component, length, boundary pressures, and vertical axis range.
Profile does not cover 100 kmCheck the component, axis units, and model pipeline length.
Results do not change after editingSubmit a new job and make sure you are viewing it rather than a historical job.
Flow sign differs from expectationsInterpret signs using port directions; compare absolute standard volume flow for continuity in this example.

Next Step​

See Transmission Pipeline for friction, discretization, elevation, and external heat transfer, or AI-Assisted Modeling and Simulation for checks of model connections, job logs, and key results.