Single-Port Relief Valve

Opens and closes automatically with inlet pressure and discharges gas to a specified backpressure.

Component Appearance and Location​

Find Single-Port Relief Valve under Pipes and Valves.

Created with Fabric.js 5.3.0

Ports and Connections​

Connect port 0 to the protected node and set Discharge Backpressure in MPa(g). Enter zero when discharge absolute pressure equals the global gauge reference. Use a Two-Port Relief Valve for a solved discharge header.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Discharge Flow ModelHydraulicModelchoiceEquivalent Nozzle / Pressure-Squared Difference / Approximate OrificeEquivalent nozzle approximates Saint-Venant–Wantzel isentropic flow; pressure-squared uses absolute-pressure squares and mean-state Z; approximate orifice uses empirical expansion and inlet heat capacity. Shared Kv/characteristics, all subcritical/critical. Reinitialize/check after switching.
Characteristic TypeValveCurveTypechoiceLinear / Equal-Percentage / Parabolic / CustomOpening–Kv relation. Two-state uses only full-open point/custom 100% endpoint; curve action uses actual opening.
Full-Open Kv [m³/(h·bar⁰ᐧ⁵)]FullOpenKVreal5000Positive Kv at 100% from equipment data; shared across discharge models, which determine flow.
Zero-Opening Kv [m³/(h·bar⁰ᐧ⁵)]FullCloseKVreal0Zero-opening characteristic endpoint affects partial-opening capacity. No greater than open Kv. Fully closed flow is zero; this is not leakage.
Valve Kv CurveCurveLibraryValveKvNamechoice__UNSELECTED__Opening–Kv curve covering 0%/100%, linearly interpolated. Two-state uses last point; curve action actual opening. Standby open/zero Kv unused.
Discharge Backpressure [MPa(g)]BackPressurereal0Fixed discharge gauge backpressure; zero for the global gauge reference environment. Forward relief needs inlet above backpressure and an open valve.

Operating Constraints

NamekeyTypeDefault / OptionsDescription
Pressure Action ModelActionModelchoiceTwo-State Pop Action / Independent Opening/Closing CurvesTwo-state switches fully open/closed and holds within hysteresis. Independent curves move with opening/closing times and hold within the band; reversals continue from current opening.
Opening Pressure [MPa(g)]MaxOnPressurereal10Opening triggers at/above inlet threshold: immediate for two-state, timed curve otherwise. Does not clamp inlet pressure; backpressure affects capacity, not threshold.
Closing Pressure [MPa(g)]MaxOffPressurereal8Closing triggers at/below threshold, strictly below opening. Two-state immediate, curve timed; hysteresis holds state/opening.
Initial Actual Opening [%]InitialOpeningreal0Curve-action initial opening. Transient first frame uses it, action starts at first positive step. Steady hysteresis retains it; outside uses thresholds. Continuation restores opening/progress.
Opening Full-Stroke Time [s]OpenTimereal50→100% opening duration. Zero immediate; partial travel continues at current curve position for remaining time.
Opening Action CurveCurveLibraryOpeningMotionNamechoice__UNSELECTED__Opening action from (0,0) to (100,100), both columns strictly increasing; 2–100 points, linear interpolation, continuation from current opening.
Closing Full-Stroke Time [s]CloseTimereal5100→0% closing duration. Zero immediate; partial travel uses remaining curve time.
Closing Action CurveCurveLibraryClosingMotionNamechoice__UNSELECTED__Closing action from (0,100) to (100,0); time strictly increasing, opening strictly decreasing; 2–100 points, linear interpolation from current opening.

Parameter Guidance​

  • Discharge model. Choose equivalent nozzle, pressure-squared difference, or approximate orifice according to equipment data. Built-in characteristics use full-open Kv, with zero-opening Kv also required for independent opening and closing curves. For a custom characteristic, enter or reference an opening–Kv curve that covers 0% and 100%. Discharge flow models
  • Thresholds. Opening and closing pressures use MPa(g), with closing strictly below opening.
  • Action. Choose two-state pop action or independent curves. Curves require initial opening and separate transient opening/closing stroke times; each positive-time direction needs its action curve. Action

Enter Characteristic and Action Curves​

Choose Edit Local Curve or Reference Curve Database separately for the valve flow coefficient, opening action, and closing action curves. Enter local points or select a named curve of the same type.

CurveHorizontal axisVertical axis and requirements
Custom KvOpening percentage, strictly increasing and covering 0% to 100%Absolute Kv, nonnegative and nondecreasing, with a positive full-open value.
Opening actionFull-stroke time percentage, strictly increasing and covering 0% to 100%Actual opening percentage, strictly increasing from 0% to 100%.
Closing actionFull-stroke time percentage, strictly increasing and covering 0% to 100%Actual opening percentage, strictly decreasing from 100% to 0%.

Set the duration separately using the full-stroke time for each direction. Action curves apply during transients with independent opening and closing curves and a positive stroke time for that direction. A stroke time of zero takes the valve to the endpoint immediately. Choose a curve source.

Modeling Steps​

  1. Connect the protected side and set backpressure.
  2. Enter capacity, Kv, thresholds, and action data.
  3. Cover pressurization, relief, and reseating in transient timing; check curves and steps.
  4. Inspect inlet pressure, opening, discharge, and backpressure.

View Results​

  • Compare pressure, action state, and actual opening for opening, closing, or hold.
  • Compare relief state, effective Kv, backpressure, and flow for normal discharge, blocking, or unavailable capacity. Standard discharge uses global standard conditions.

Professional Theory​

Thresholds and Actual Opening​

Inlet gauge pressure triggers opening and reseating. Hysteresis between thresholds reduces cycling. Backpressure affects flow; action thresholds compare inlet pressure with settings.

Inlet pressureTwo-state actionIndependent curves in transients
At/above openingFully openAdvance on opening curve
At/below closingFully closedAdvance on closing curve
BetweenHold statePause and hold opening

Action curves use full-stroke time percentage horizontally and actual opening percentage vertically. Opening runs 0→100%, closing 100→0%. Retriggering or reversing continues from the current opening on the corresponding curve. Zero stroke time reaches the endpoint immediately on triggering. Curve Database

For independent curves, steady-state determines opening from solved inlet pressure, using initial actual opening within hysteresis. The transient initial frame uses initial opening; action advances from the first positive step. Continuation restores saved opening and progress.

Discharge Flow Models​

Let pp and pbp_b be inlet/backpressure absolute pressures in Pa and m˙\dot m discharge in kg/s. Two-state full opening uses full-open Kv or the custom 100% endpoint. Independent curves use actual opening and zero-opening Kv as a characteristic endpoint. Flow is zero if fully closed, effective Kv is zero, or p≤pbp\le p_b. Effective Kv

For permitted discharge, r=pb/pr=p_b/p. Flow is subcritical for r>rcr>r_c and critical for r≤rcr\le r_c. With fixed inlet state and effective Kv, lowering backpressure in the critical regime does not increase flow.

Equivalent Nozzle​

Use the inlet ideal-gas heat capacity ratio γ0=Cp,0/Cv,0\gamma_0=C_{p,0}/C_{v,0} for the critical ratio. With inlet density ρin\rho_{\mathrm{in}} in kg/m³ and equivalent area Aeff=Kv/(3600200)A_{\mathrm{eff}}=K_v/(3600\sqrt{200}) in m²,

rc=(2γ0+1)γ0/(γ0−1),re=max⁡(r,rc).r_c=\left(\frac{2}{\gamma_0+1}\right)^{\gamma_0/(\gamma_0-1)}, \qquad r_e=\max(r,r_c). m˙=Aeff2ρinp γ0γ0−1(re2/γ0−re(γ0+1)/γ0).\dot m=A_{\mathrm{eff}}\sqrt{ 2\rho_{\mathrm{in}}p\, \frac{\gamma_0}{\gamma_0-1} \left(r_e^{2/\gamma_0}-r_e^{(\gamma_0+1)/\gamma_0}\right)}.

Pressure-Squared Difference​

Use regulator effective mean pressure: pe=max⁡(pb,p/2)p_e=\max(p_b,p/2), pm=(p+pe)/2p_m=(p+p_e)/2, with inlet gas and temperature. Substitute pp, pbp_b, and effective Kv into the regulator capacity formula. Critical ratio is 0.5. Formula

Approximate Orifice​

Estimate kek_e from inlet temperature and mean molar mass. Clamp temperature TRT_R to 510–710 °R and molar mass MeM_e to 15–100 kg/kmol. The correlation is

ke=1.0836−0.000115TR+5.61−0.002TRMe.k_e=1.0836-0.000115T_R+\frac{5.61-0.002T_R}{M_e}.

Replace γ0\gamma_0 by kek_e in the nozzle critical-ratio formula and set re=max⁡(r,rc)r_e=\max(r,r_c). Evaluate throat density ρt\rho_t at pt=prep_t=pr_e and Tt=Tinre(ke−1)/keT_t=T_{\mathrm{in}}r_e^{(k_e-1)/k_e} in K. Estimate velocity with inlet ideal-gas heat capacity cp,inc_{p,\mathrm{in}} in J/(kg·K), giving

m˙=Aeffρt2cp,in(Tin−Tt).\dot m=A_{\mathrm{eff}}\rho_t \sqrt{2c_{p,\mathrm{in}}\left(T_{\mathrm{in}}-T_t\right)}.

Applicability and Limits​

  • Covers single-phase gas at fixed backpressure. Use a Two-Port Valve for header accumulation, losses, or shared headers.
  • Opening pressure triggers action; protected pressure still depends on supply, network, and capacity. Check rated capacity and selection against equipment data and standards.
  • Temperature/composition results describe the inlet. Orifice temperature is for capacity; model the discharge network to inspect its temperature.

Common Inspections​

  • Open with no flow. Compare inlet/backpressure, then opening and Kv.
  • Pressure still rises. Check full stroke, supply, capacity, and backpressure; assess critical discharge with inlet state and Kv.
  • Delayed reseating. Check closing threshold and backpressure; high backpressure may prevent reaching reseat pressure. Check closing time and opening for curve action.
  • Unexpected opening. Check model, initial opening, hysteresis, curve direction/reference/timing, and saved continuation state.