Local Resistance

Represents extra losses from bends, a tee flow path, contractions/expansions, filters, and equipment connections through a two-port lumped pressure-drop relation, with no gas storage.

Component Appearance and Location​

Expand Pipeline Valve in the component library on the left and find "Local Resistance".

Created with Fabric.js 5.3.0

Ports and Connections​

Port KeyTypeDirectionInterface NameDisplay Conditions
0FLUIDinputfluid inletalways show
1FLUIDoutputFluid outletalways show

Ports connect the physical network. Positive flow is 0→1; reverse flow is permitted. Read measurements through a measurement instrument; this device has no control ports.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Flow Internal Diameter [mm]Diameterreal50Actual reference-section internal diameter for the loss coefficient. Do not substitute nominal/outside diameter.
Local Loss CoefficientLocalResistanceCoefficientreal1Dimensionless loss coefficient from equipment/tests, matching diameter/velocity basis. Fixed for both directions, no automatic Reynolds correction. Default 1 is not universal. Zero leaves connected with no local loss. No local throttling-temperature model.

Parameter Guidance​

  • Internal diameter. Enter mm for the coefficient reference section. At contractions/expansions, identify which velocity the data use and enter that section diameter.
  • Loss coefficient. A dimensionless dynamic-pressure multiplier from equipment/test data, fixed and shared by both directions. Zero keeps the path connected at equal pressures; the network determines flow.

Modeling Steps​

  1. Add the component in series at the extra-loss location.
  2. Enter reference-section diameter.
  3. Enter coefficient from handbook, equipment, or tests; check dynamic-pressure bases before combining losses.
  4. Use a measurement instrument if needed.
  5. Check direction, differential, and temperature/composition transport.

View Results​

  • Pressure. Ports use MPa(g); port-0 minus port-1 differential uses kPa and may be negative in reverse flow.
  • Flow. Trends show standard Nm³/h; monitoring also shows local actual m³/h. Standard values use global references; actual values use each port state.

Professional Theory​

The local resistance model consists of the mass conservation equation and the local pressure loss equation. Resistance always consumes mechanical energy, and the direction of pressure loss changes with the actual flow direction.

1. Main Symbols​

SymbolMeaningUnit
q0,q1q_0,q_1Actual port flows, positive 0→1m³/s
p0,p1p_0,p_1Absolute pressuresPa
ρ0,ρ1\rho_0,\rho_1Local densitieskg/m³
qupq_{\mathrm{up}}Signed actual upstream flowm³/s
ρup\rho_{\mathrm{up}}Upstream densitykg/m³
DDEquivalent internal diameterm
AAReference aream²
vupv_{\mathrm{up}}Mean velocity on reference aream/s
KLK_LLoss coefficient—

The flow area is calculated from the inner diameter:

A=πD24.A=\frac{\pi D^2}{4}.

2. Conservation of Mass​

Local resistance does not store gas, so both steady-state and transient calculations satisfy:

ρ0q0=ρ1q1.\rho_0 q_0=\rho_1 q_1.

Different port densities give different actual volume flows at the same mass flow.

3. Local Pressure Loss​

Bends and area changes disturb flow and dissipate mechanical energy. The lumped model estimates loss magnitude ΔpL\Delta p_L as reference dynamic pressure times KLK_L.

vup=qupA,ΔpL≈KLρupvup22.v_{\mathrm{up}}=\frac{q_{\mathrm{up}}}{A}, \qquad \Delta p_L\approx K_L\frac{\rho_{\mathrm{up}}v_{\mathrm{up}}^2}{2}.

Using positive direction 0→1, the signed relation is

p0−p1≈KLρup2A2qup∣qup∣.p_0-p_1 \approx\frac{K_L\rho_{\mathrm{up}}}{2A^2} q_{\mathrm{up}}\left|q_{\mathrm{up}}\right|.

Use actual upstream flow/density: port 0 forward, port 1 reverse. Area always follows entered diameter. Flow magnitude is smoothed near zero for solving. Loss follows actual direction and, at fixed upstream flow, density, and coefficient, scales approximately as D−4D^{-4}.

4. Coefficient Conversion and Combination​

For equivalent straight length LeL_e, estimate KLK_L using Darcy factor ff at the same reference diameter and state.

KL≈fLeD.K_L\approx f\frac{L_e}{D}.

This matches losses at equal reference dynamic pressure. Changing friction can change equivalent K. Prefer applicable measured equipment data where available. DOE Fundamentals Handbook, Volume 3

To convert KaK_a from reference aa to bb at one operating condition, preserve loss Kρv2/2K\rho v^2/2.

Kb=Kaρava2ρbvb2.K_b=K_a\frac{\rho_a v_a^2}{\rho_b v_b^2}.

Add series coefficients directly only when losses are approximately independent and share dynamic pressure. Otherwise model separately or convert bases first. Check fixed-coefficient validity if dynamic-pressure ratios vary, and prefer combined-fitting data for closely interacting fittings.

5. Temperature and Component Transfer​

With flow, downstream inherits upstream temperature and composition.

Tdown=Tup.T_{\mathrm{down}}=T_{\mathrm{up}}.

Transport reverses with flow. At zero flow, each side retains temperature and composition.

Applicability and Limits​

  • Fixed loss. Check validity for direction-dependent behavior, Reynolds-number variation, or blockage. Choking and static-pressure recovery need corresponding models.
  • Two-port path. Network connections represent tee branches; this models one path loss. Use pipes for distributed losses/storage, and valves for switching/regulation/checking.
  • Thermal behavior. Temperature passes through even in non-isothermal mode. Real-gas enthalpy may differ with pressure despite equal temperature. Use suitable thermal models for Joule–Thomson effects, dissipation heating, or external transfer.

Common Inspections​

  • Unexpected loss scale. Check mm diameter, reference section, and double-counted equivalent length. Use actual upstream density and m³/s in formulas.
  • Negative differential. Check signs; reverse flow still loses pressure along its direction.
  • Flow with zero drop. Check zero coefficient.
  • Different readings. Check adapter target, port, quantity, time, basis, and units.