Skip to main content

Check Valve

Check valves are used to restrict the flow of gas from the inlet to the outlet. When the forward pressure difference reaches the opening condition, the gas passes according to the valve flow characteristics; when the forward pressure difference is insufficient or a reverse flow trend occurs, the valve automatically closes.

Component Appearance and Location​

Expand Pipeline Valve in the component library on the left and find "Check Valve".

Created with Fabric.js 5.3.0

Ports and Connections​

Port KeyTypeDirectionInterface NameDisplay Conditions
0FLUIDinputfluid inletalways show
1FLUIDoutputFluid outletalways show

The fluid inlet should be connected upstream and the fluid outlet should be connected downstream. The check valve has no control port, and its opening and closing status is automatically determined by the pressure conditions before and after the valve.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Gas Valve Hydraulic ModelHydraulicModelchoiceExpansion/Choked Flow / Pressure-Squared DifferenceExpansion/choked flow needs xT. Pressure-squared flow chokes at absolute ratio ≤0.5 without xT. Both share Kv/characteristics; results can differ. Reinitialize after switching.
Cracking Differential [kPa]CrackingPressurereal0Minimum forward differential to open. Below it or in reverse, closed. Once open, full differential determines flow; cracking pressure is not subtracted as extra loss. Zero permits positive differential.
Fixed Forward Opening [%]InitialOpeningreal100Fixed forward capacity opening during the entire simulation, in percent: 1 means 1%.
Characteristic TypeValveCurveTypechoiceLinear / Equal-Percentage / Parabolic / User-DefinedOpening–Kv relation; custom mode selects a database valve curve.
Full-Open Kv [m³/(h·bar⁰ᐧ⁵)]FullOpenKVreal5000Kv at 100%, positive and at least closed leakage Kv.
Closed Leakage Kv [m³/(h·bar⁰ᐧ⁵)]FullCloseKVreal0Forward leakage Kv at 0%, no greater than open Kv. Zero seals ideally; leakage still needs forward opening conditions. Reverse remains blocked.
Valve Kv CurveCurveLibraryValveKvNamechoice__UNSELECTED__Vendor opening–Kv curve with 0%/100% endpoints and linear interpolation. Values directly define Kv; standby open/closed Kv are unused.
Critical Ratio SourceXTSourcechoiceConstant / Curve DatabaseFixed xT or opening-dependent curve, evaluated at fixed forward opening.
Critical Pressure-Drop Ratio xTXTreal0.7Expansion/choked-flow coefficient in (0,1]. Prefer vendor data; default 0.7 is estimated.
Valve xT CurveCurveLibraryXTNamechoice__UNSELECTED__Opening horizontally, xT vertically; linear interpolation at fixed forward opening. Cover 0%/100%, with xT in (0,1].

Parameter Guidance​

  • Cracking pressure. Connect in the designed direction and enter the required forward differential in kPa. It determines conduction; once open, full actual pressure difference determines flow.
  • Capacity. Forward Flow Opening is fixed during simulation and sets effective Kv when the valve is open. Enter open and closed Kv for built-in characteristics, or enter or reference an absolute Kv curve.
  • Hydraulics. Expansion/choked flow uses fixed or opening-dependent xT; pressure-squared flow uses pressure and properties. For zero flow, first check forward differential and effective Kv.

Enter Characteristic Curves​

Select separate sources for custom Kv and opening-dependent xT. Edit Local Curve uses points stored on this valve. Reference Curve Database selects a named curve of the same type. Both curves use opening from 0% to 100%. See the shut-off valve curve requirements for endpoints, absolute Kv, and xT. Choose a curve source.

The check valve evaluates these curves at the fixed Forward Flow Opening.

Modeling Steps​

  1. Orient inlet upstream and outlet downstream.
  2. Select hydraulic model and characteristic from valve data.
  3. Set the fixed forward opening. Enter full-open and closed Kv for a built-in characteristic. For a custom characteristic, enter local opening–Kv points or select a database curve.
  4. Set cracking differential from equipment/engineering data, not network gauge pressure.
  5. Check differential, flow direction, and conduction.

View Results​

The calculation results of the check valve should focus on checking:

  • The pressure in front of the valve, the pressure behind the valve and the pressure difference between both ends;
  • flow rate and flow direction through check valves;
  • Whether forward flow is formed after the forward pressure difference reaches the opening condition;
  • When the forward pressure difference is insufficient or a reverse flow trend occurs, whether the flow rate drops to zero;
  • Whether the pressure drop in the open state is consistent with the set opening and flow coefficient;
  • In non-isothermal calculations, are the temperature changes before and after the valve reasonable?

Check valves have no external control setpoint. When judging its operating status, a comprehensive analysis should be combined with flow rate, flow direction and pressure difference before and after the valve.

Professional Theory​

Opening and Closing Conditions​

Let Δp=pin−pout\Delta p=p_{\mathrm{in}}-p_{\mathrm{out}} and cracking differential be Δpcr\Delta p_{\mathrm{cr}}, all in Pa with absolute port pressures. If effective Kv permits conduction, the pressure condition is

Δp>0,Δp≥Δpcr.\Delta p>0,\qquad \Delta p\geq\Delta p_{\mathrm{cr}}.

Both flows are zero for zero/reverse pressure difference, insufficient cracking differential, or insufficient effective Kv. Even a zero cracking setting requires positive forward differential.

Fixed Forward Opening​

The fixed opening sets effective Kv and opening-dependent xT. At 0% with nonzero closed Kv, forward leakage still requires the conduction conditions. Effective Kv

Hydraulic Relations After Opening​

Once conducting, inlet is upstream and the full differential determines flow. Cracking pressure is only an opening criterion. Both models use the shut-off valve formulas.

  • Expansion/choked flow uses fixed or curve-based xT. Model
  • Pressure-squared flow uses inlet properties and absolute pressures. Model

Mass Conservation and Throttling Temperature​

During conduction, composition passes downstream and conservation and non-isothermal throttling follow the Shut-off Valve. When closed, cross-port mass, energy, and species transport are zero.

Applicability and Limits​

  • Installation determines allowed direction; reversed installation blocks intended supply.
  • Prevents reverse flow; does not regulate pressure or actively control flow.
  • Disc inertia, impact, and vibration are outside scope; use specialized valve dynamics for fast-action impact analysis.

Common Inspections​

  • Check orientation.
  • Enter cracking differential in kPa, not gauge pressure.
  • For zero forward flow, check pressure difference against cracking pressure.
  • Custom opening points must be unique and cover the used range.
  • For unexpected drop, check fixed opening, Kv, and custom data.