Delay
The historical input signal is output according to the set delay time, which is used to describe the response lag in measurement, communication or execution links.
Component Appearance and Location
Expand Controller in the component library on the left and find "Delayer".
Ports and Connections
| Port Key | Type | Direction | Interface Name | Display Conditions |
|---|---|---|---|---|
0 | CONTROL | input | Input signal port | always show |
1 | CONTROL | output | Output signal port | always show |
The input terminal receives the current signal, and the output terminal provides the delayed historical signal. This component only connects to the signaling network.
Parameter List
Basic Parameters
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Delay Time [s] | DelayTime | real | 5 | Delay Time |
| Initial Output Signal | InitialValue | real | 0 | Initial Output Signal |
Parameter Guidance
- Delay Time (s). A positive value delays changes by that duration; zero passes the current input directly.
- Initial Output Signal. With positive delay, used until the first input sample arrives after the delay. Match input units, initial conditions, and downstream range.
Modeling Steps
- Connect input to port
0and set Delay Time and Initial Output Signal. - Connect port
1downstream. Place oscilloscopes at input and output if needed. - Run transient simulation and compare when the same change appears on each side. Oscilloscope
View Results
With positive delay, output first holds its initial value, then reproduces recorded input changes in sequence. Subtract input change times from output change times. Between valid updates, the previous output is held.
Professional Theory
For delay and recorded samples , output at control instant is the latest sample satisfying . If none qualifies, output is initial value .
Pure signal simulation can schedule updates at sample arrival times. In coupled network simulation, arrived historical samples are read at actual control evaluations. With zero delay, . Output units match input units in both cases.
Applicability and Limits
- Fixed transmission delay. Models a late-arriving signal. Gradual change or attenuation requires separate dynamics.
- Feedback. Positive delay uses history and can break instantaneous dependency loops. Zero delay remains a direct path.
- Continuation. Continuing the same runtime state preserves history; a new transient job starts new history from Initial Output Signal.
Common Inspections
- Output stays initial. Check first sample arrival time and whether input changed.
- Initial jump. Check initial units, conditions, and downstream limits.
- No visible delay. Compare time axes, delay, and recording times.
- Dependency loop remains. Check that the feedback delay is positive.