Divider

Calculates the ratio of the dividend to the divisor for use in normalization, scaling, and signal scaling.

Component Appearance and Location​

Expand Controller in the component library on the left and find "Divider".

Created with Fabric.js 5.3.0

Ports and Connections​

Port KeyTypeDirectionInterface NameDisplay Conditions
0CONTROLinputdividend signal portalways show
1CONTROLinputDivisor signal portalways show
2CONTROLoutputOutput signal portalways show

The port sequence determines the operation relationship: port 0 is the dividend, port 1 is the divisor, and port 2 outputs the calculation result.

Parameter List​

Divider has no parameters to display.

Parameter Guidance​

Connect numerator to port 0 and denominator to 1. A Constant Input can provide a nonzero normalization reference.

Modeling Steps​

  1. Connect inputs and check directions, units, and scales.
  2. Check the denominator during startup, shutdown, and normal operation.
  3. Connect port 2 downstream, run transient simulation, and compare simultaneous numerator, denominator, and ratio.

View Results​

Away from zero denominator, output should match the current input ratio. A smaller time step cannot define division by zero: check denominator source and conditions. Check it first if results or logs report missing control output.

Professional Theory​

For nonzero denominator u1(t)u_1(t), output is

y(t)=u0(t)u1(t).y(t)=\frac{u_0(t)}{u_1(t)}.

Output units are numerator units divided by denominator units. Matching units and references can produce a dimensionless ratio. Both current inputs must be ready. Signal Updates

With zero denominator, NexusFlow has no valid quotient to pass downstream for that evaluation. A nonzero denominator near zero can produce a large quotient even with little numerator change.

Applicability and Limits​

  • Normalization and ratios. A fixed reference must be finite, nonzero, and consistent with the input basis. Convert both pressures to the same absolute-pressure unit for pressure ratios. Reference Conditions
  • Possible zero flow or command. For dynamic denominators, define valid application behavior near zero in control logic.

Common Inspections​

  • Missing output or stopped control. Check for zero denominator and valid sources.
  • Quotient spike. Check a near-zero denominator or a changing measurement used as a fixed reference.
  • Unexpected magnitude or sign. Check port order, units, and pressure references.