Divider
Calculates the ratio of the dividend to the divisor for use in normalization, scaling, and signal scaling.
Component Appearance and Location
Expand Controller in the component library on the left and find "Divider".
Ports and Connections
| Port Key | Type | Direction | Interface Name | Display Conditions |
|---|---|---|---|---|
0 | CONTROL | input | dividend signal port | always show |
1 | CONTROL | input | Divisor signal port | always show |
2 | CONTROL | output | Output signal port | always show |
The port sequence determines the operation relationship: port 0 is the dividend, port 1 is the divisor, and port 2 outputs the calculation result.
Parameter List
Divider has no parameters to display.
Parameter Guidance
Connect numerator to port 0 and denominator to 1. A Constant Input can provide a nonzero normalization reference.
Modeling Steps
- Connect inputs and check directions, units, and scales.
- Check the denominator during startup, shutdown, and normal operation.
- Connect port
2downstream, run transient simulation, and compare simultaneous numerator, denominator, and ratio.
View Results
Away from zero denominator, output should match the current input ratio. A smaller time step cannot define division by zero: check denominator source and conditions. Check it first if results or logs report missing control output.
Professional Theory
For nonzero denominator , output is
Output units are numerator units divided by denominator units. Matching units and references can produce a dimensionless ratio. Both current inputs must be ready. Signal Updates
With zero denominator, NexusFlow has no valid quotient to pass downstream for that evaluation. A nonzero denominator near zero can produce a large quotient even with little numerator change.
Applicability and Limits
- Normalization and ratios. A fixed reference must be finite, nonzero, and consistent with the input basis. Convert both pressures to the same absolute-pressure unit for pressure ratios. Reference Conditions
- Possible zero flow or command. For dynamic denominators, define valid application behavior near zero in control logic.
Common Inspections
- Missing output or stopped control. Check for zero denominator and valid sources.
- Quotient spike. Check a near-zero denominator or a changing measurement used as a fixed reference.
- Unexpected magnitude or sign. Check port order, units, and pressure references.