Skip to main content

Measurement Instrument

A measurement instrument reads an operating quantity from one device instance and sends it into the control network. It can provide pressure, flow, temperature, inventory, power, or state for monitoring and feedback.

Component Appearance and Location​

Expand Signals and Communication in the component library and add Measurement Instrument.

Ports and Connections​

Port keyTypeDirectionConnection
signalCONTROLOutput (OUT)Connect to a PID controller PV, arithmetic component input, or oscilloscope input.

Select the target device in the instrument parameters. One measurement output can feed several inputs.

Parameters​

Basic Parameters

NamekeyTypeDefault / OptionsDescription
Target Device CategoryTargetComponentClasschoice__UNSELECTED__Target equipment category in the current model.
Target Device LabelTargetComponentIdchoice__UNSELECTED__Select by label and component ID. Copies retain the original target.
Signal OptionSignalKeychoice__UNSELECTED__Select a signal from the target device. Check the selection if the device configuration changes.

Parameter Guidance​

  • Connected device category. Add the target equipment before selecting a category that supports measurements in the current model.
  • Connected device label. Select the instance. Use component IDs to distinguish identical names. Copying the instrument keeps the original target. Reselect the label to bind a copied device.
  • Signal option. Select the quantity and location, such as inlet, outlet, tank interior, or a specified port. Check whether the value uses gauge pressure, standard flow, or actual flow. Port, species, and gas choices depend on the selected equipment and global configuration.

The measurement instrument is an output source. Recheck the signal option after changing the equipment, number of ports, gas, or control objective.

Modeling Steps​

  1. Connect and configure a source, short pipe, and load, then add a measurement instrument.
  2. Select the short pipe category and the label of the pipe to observe.
  3. Select inlet or outlet pressure, or choose a flow or temperature measurement.
  4. Connect the signal output to an oscilloscope or the PV input of a PID controller.
  5. Validate and save. Run a transient and compare the equipment result and signal at the same time.

For external computation, bind the instrument's signal output in the platform-to-external input channel table of the communication interface. See Build a gas network control system.

Sources, short pipes, and loads support measurements. To change a source or load boundary, use its own parameters and boundary schedule.

View Results​

The current measurement is the device value computed at the relevant time. The oscilloscope records its trend. A controller can use it as feedback. Confirm the target instance and measurement point, then compare the same quantity in the device results.

Professional Theory​

Measurement Direction and Engineering Units​

The signal retains the engineering meaning of the selected quantity. Keep gauge pressure distinct from differential pressure, and standard volumetric flow distinct from actual volumetric flow. Flow direction follows the selected device and port convention. Gauge pressure uses the global gauge reference. See Set reference conditions.

Transient Control Timing​

The steady-state solve and the initial transient solve use the equipment's own physical conditions. The control network then forms the initial measurements and updates them at accepted physical times. Use a transient to observe changes over time. The measurement leaves the physical state of the device unchanged.

Common Checks​

  • Empty device category. Confirm that the equipment is already in the model. If an updated workbench still shows old options, save, refresh the page, and reselect the category, label, and signal.
  • Invalid previous selection. Check whether the target has been removed, its category changed, its ID duplicated, or its ports or gas configuration changed.
  • Mismatched values. Compare equipment, point, quantity, unit, and time.
  • No controller or oscilloscope input. Verify that signal connects to an input and has a single driver.