Centrifugal Compressor
Uses maps, suction state, and network conditions to solve pressure, flow, temperature, speed, and shaft power for compression, parallel loading, and anti-surge studies.
Component Appearance and Location
Expand Compressor in the component library on the left and find "Centrifugal Compressor".
Ports and Connections
| Port | Type | Direction | Use |
|---|---|---|---|
0 | FLUID | Input | Suction network |
1 | FLUID | Output | Discharge network |
Compression flows inlet to outlet. Stopped flow depends on bypass/check settings. Bind signals using a measurement instrument or actuator.
Modeling Steps
- Connect suction/discharge.
- In Equipment Specifications, select the map type and source. Use Edit Local Curve to enter points on the component or Reference Curve Database to select a named map of the same type.
- Set initial state/count/mode/target and maximum speed.
- Configure constraints, protection, anti-surge, and stopped paths. Check steady-state before transient plans/signals.
- Compare targets, actual values, constraints, loads, compression, recycle, and bypass.
Parameter List
Equipment Specifications
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Parameter Version | CentrifugalCompressorConfigVersion | choice | 2 | No description. |
| Performance Map Type | HeadMapType | choice | Polytropic Head Map / Adiabatic Head Map / Pressure Ratio–Flow Map | Match vendor map: polytropic head/efficiency or adiabatic head/ratio with adiabatic efficiency. Columns are speed, per-unit impeller inlet actual flow, head/absolute ratio, efficiency. |
| Polytropic Head Map | CurveLibraryHeadMapName | choice | __UNSELECTED__ | Select matching vendor/test map: speed, per-unit impeller flow, head in m, fractional efficiency. Endpoints define surge/stonewall. Off-map speed uses similarity, subject to equipment limits. |
| Adiabatic Head Map | CurveLibraryAdiabaticHeadMapName | choice | __UNSELECTED__ | Select matching vendor/test map: speed, per-unit impeller flow, head in m, fractional efficiency. Endpoints define surge/stonewall. Off-map speed uses similarity, subject to equipment limits. |
| Pressure Ratio–Flow Map | CurveLibraryPressureRatioMapName | choice | __UNSELECTED__ | Select a shared pressure-ratio map. The columns are speed in rpm, per-unit impeller inlet volumetric flow at operating conditions in m³/h, absolute pressure ratio, and adiabatic efficiency as a fraction. The endpoints of each speed line mark the surge and stonewall limits. |
Initial Conditions
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Initial Operating State | Status | choice | Run / Stop | Steady-state and new transient initialization use panel requests/settings. Later plans/signals govern, subject to constraints/protection. |
| Parallel Running Units [units] | NRN | integer | 1 | Positive integer count of identical parallel units; use state to stop. Flow/power are per unit and summed by count; pressure, ratio, and common bypass are not multiplied. |
| Operating Control Mode | ControlTarget | choice | Fixed Speed / Fixed Outlet Pressure / Fixed Inlet Pressure / Fixed Standard Flow / Fixed Shaft Power / Fixed Pressure Ratio | Select the quantity maintained through speed adjustment, subject to maps/network/constraints. Panel values establish steady-state/initial fields; loaded fields retain physical state before new control. |
| Speed Setpoint [rpm] | SpeedSetpoint | text | 4500 | Requested rpm, subject to performance and constraints. Zero requests normal stop. |
| Outlet Pressure Setpoint [MPa(g)] | DischargePressureSetpoint | text | 1.5 | Outlet-connection gauge target, jointly determined with network and constraints. |
| Inlet Pressure Setpoint [MPa(g)] | SuctionPressureSetpoint | text | 1 | Inlet-connection gauge target, jointly determined with network and constraints. |
| Per-Unit Net Standard Flow Setpoint [Nm³/h] | FlowrateSetpoint | text | 1000 | Per-unit net standard delivery excluding internal recycle; global references apply. Group sums by count. Zero remains Run and can use recycle for zero net delivery. |
| Per-Unit Shaft Power Setpoint [kW] | PowerSetpoint | text | 50 | Per-unit input shaft-power target, summed by count; not electrical consumption. Zero requests normal stop. |
| Pressure Ratio Setpoint | PressureRatioSetpoint | text | 1.5 | Finite positive external absolute pressure ratio, including compression and internal loss. Never divide gauge pressures; performance/constraints determine reachability. |
Control Source and Operating Schedule
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Control Source | ControlMode | choice | Operating Schedule / Signal Control | Transient only. Schedules use panel initial state/future events; signals apply after physical initialization. Switching sources retains standby settings. |
| Signal Control Contents | SignalControlMode | choice | Setpoint Only / Run/Stop Only / Run/Stop and Setpoint | Signals control setpoint, run/stop, or both. Run-only retains panel target. Held 0 means Stop, 1 permits Run subject to protection/eligibility. |
| Startup Time [s] | StartupDuration | real | 120 | Positive zero-to-maximum-speed reference time. Acceleration rate is maximum speed/time for startup and adjustments; actual duration depends on speed change. |
| Stop Time [s] | ShutdownDuration | real | 60 | Positive maximum-to-zero reference time. Normal stop/deceleration uses maximum speed/time and ends at target/zero. Protection uses separate trip action. |
| Operating Schedule | OperatingPlan | table | Configure one row at a time | Rows activate state/count/mode/target together at unique increasing future times. Past/start rows do not execute. Flow/power are per unit. Steady-state/signal mode ignores this table. Commands continue from actual speed using startup/stop rates and operating constraints. |
| Operating Schedule / Effective Time | OperatingPlan.time | datetime | 2025-01-01 00:00:00 | Valid datetime; past/start rows remain informational, future rows activate at their times. |
| Operating Schedule / Operating State | OperatingPlan.status | choice | Run / Stop | State applies with count/target; do not use zero count to stop. |
| Operating Schedule / Parallel Running Units [units] | OperatingPlan.nrn | integer | 1 | Positive integer, switched immediately. Normal rundown retains previous actual units. |
| Operating Schedule / Operating Control Mode | OperatingPlan.controlTarget | choice | Fixed Speed (rpm) / Fixed Outlet Pressure (MPa(g)) / Fixed Inlet Pressure (MPa(g)) / Fixed Standard Flow (Nm³/h, per unit) / Fixed Shaft Power (kW, per unit) / Fixed Ratio (dimensionless) | Mode for this row; enter the target in its displayed units. |
| Operating Schedule / Setpoint (Units Depend on Mode) | OperatingPlan.setpoint | text | — | Target according to row mode: per-unit flow/power, gauge pressure, or absolute pressure ratio. |
Operating Constraints and Protection
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Minimum Normal Speed | EnableMinimumSpeedRPM | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Normal Speed [rpm] | MinimumSpeedRPM | text | — | Minimum normal actual speed; waived during finite startup/normal stop, active during normal running/adjustments. |
| Maximum Allowable Speed [rpm] | MaximumSpeedRPM | text | — | Positive equipment maximum speed, always active and the reference for all normal speed ramp rates. |
| Enable Minimum Inlet Pressure | EnableMinimumSuctionPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Inlet Pressure [MPa(g)] | MinimumSuctionPressure | text | — | Minimum inlet gauge pressure with positive converted absolute pressure. Always active during startup/stop; independent of protection thresholds. |
| Enable Maximum Outlet Pressure | EnableMaximumOutletPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Outlet Pressure [MPa(g)] | MaximumOutletPressure | text | — | Maximum outlet gauge pressure with positive absolute pressure. Always active; independent of high-pressure protection thresholds. |
| Enable Per-Unit Minimum Net Standard Flow | EnableMinimumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Net Standard Flow [Nm³/h] | MinimumFlowrate | text | — | Per-unit minimum net standard flow, excluding recycle, at global standards. Zero is zero minimum. Waived in finite startup/normal stop; does not replace anti-surge. |
| Enable Per-Unit Maximum Net Standard Flow | EnableMaximumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Net Standard Flow [Nm³/h] | MaximumFlowrate | text | — | Per-unit maximum net standard flow excluding recycle. Zero is a real zero limit; disable to remove. Active during startup/stop. |
| Enable Per-Unit Minimum Shaft Power | EnableMinimumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Shaft Power [kW] | MinimumPower | text | — | Per-unit minimum shaft power, not electrical power. Zero is allowed. Waived in finite startup/normal stop; group totals use actual count. |
| Enable Per-Unit Maximum Shaft Power | EnableMaximumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Shaft Power [kW] | MaximumPower | text | — | Per-unit maximum shaft power. Zero is a real zero limit; disable to remove. Always active; group totals use actual count. |
| Enable Minimum Operating Ratio | EnableMinimumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Ratio | MinimumPressureRatio | text | — | Positive minimum external absolute ratio, possibly below 1. Waived in finite startup/normal stop; never use gauge ratios. |
| Enable Maximum Operating Ratio | EnableMaximumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Ratio | MaximumPressureRatio | text | — | Positive maximum external absolute ratio, possibly below 1; active during startup/stop. |
| Enable Maximum Outlet Temperature | EnableMaximumOutletTemperature | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Outlet Temperature [℃] | MaximumOutletTemperature | text | — | Actual outlet temperature upper limit, always active. Isothermal mode checks global temperature. |
| Constraint Recovery Wait [s] | ConstraintRecoveryDelay | real | 0 | Standby recovery needs continuous Run and feasibility for this wait; interruption restarts it. Zero still requires eligibility; excludes startup. Transient only. |
| Enable Low Inlet Pressure Protection | EnableTripLowSuctionPressure | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| Low Inlet Pressure Trigger [MPa(g)] | TripLowSuctionPressure | text | — | Triggers at/below actual inlet gauge pressure. Steady-state warns without timing/latching; transient continuous delay causes immediate trip without normal rundown. |
| Low Inlet Pressure Release [MPa(g)] | TripLowSuctionPressureRelease | text | — | Release strictly above trigger, reached on its safe side. Release also needs wait, reset mode, Run, and feasibility before restart. |
| Low Inlet Pressure Trigger Delay [s] | TripLowSuctionPressureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Enable High Outlet Pressure Protection | EnableTripHighDischargePressure | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| High Outlet Pressure Trigger [MPa(g)] | TripHighDischargePressure | text | — | Triggers at/above outlet gauge pressure. Steady-state warns only; transient continuous delay trips without normal rundown. |
| High Outlet Pressure Release [MPa(g)] | TripHighDischargePressureRelease | text | — | Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply. |
| High Outlet Pressure Trigger Delay [s] | TripHighDischargePressureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Enable High Outlet Temperature Protection | EnableTripHighDischargeTemperature | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| High Outlet Temperature Trigger [℃] | TripHighDischargeTemperature | text | — | Triggers at/above actual outlet temperature. Steady-state warns only; transient delay trips without normal rundown. |
| High Outlet Temperature Release [℃] | TripHighDischargeTemperatureRelease | text | — | Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply. |
| High Outlet Temperature Trigger Delay [s] | TripHighDischargeTemperatureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Enable Low Speed Protection | EnableTripLowSpeed | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| Low Speed Trigger [rpm] | TripLowSpeed | text | — | Triggers at/below actual speed after continuous delay, only in normal running/adjustment. Startup/normal stop exempt. Steady-state warns only. |
| Low Speed Release [rpm] | TripLowSpeedRelease | text | — | Release strictly above trigger. Wait/reset/Run/feasibility also apply. When stopped, evaluate release against the proposed restart-point speed. |
| Low Speed Trigger Delay [s] | TripLowSpeedDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Protection Reset Mode | ProtectionResetMode | choice | Run/Stop Command Reset / Automatic Reset | Command reset requires Off, satisfied release/wait, then fresh Run. Automatic reset requires continuous release/wait. Restart still requires Run and feasibility. |
| Protection Release Wait [s] | TripRecoveryDelay | real | 0 | All latched causes must continuously satisfy release for this wait; interruption restarts it. Zero still needs release; reset/Run/feasibility govern restart. Transient only. |
Anti-Surge Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Anti-Surge Mode | AntiSurgeMode | choice | Automatic Recycle / Speed-Based Surge Avoidance / Boundary Trip / External Recycle System | Automatic recycle is ideal and cooled to inlet, without real valve capacity/time. Speed avoidance can limit target. Boundary-trip uses actual surge; external recycle uses connected network. |
| Anti-Surge Control Margin [%] | SurgeControlMargin | real | 0 | Margin above same-speed surge flow; zero puts control line on boundary. Used for automatic recycle/speed avoidance, monitoring only for boundary-trip/external recycle. Actual margin is reported. |
Bypass Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Equipment Bypass | EnableBypass | check | Off | Enables common inlet-to-outlet bypass with separate normal-stop/standby/trip path selection. Internal anti-surge recycle is separate. |
| Path After Normal Stop | StoppedFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after normal stop. Flow depends on network differential, common capacity, and check settings. |
| Path During Constraint Standby | InfeasibleFlowDisposition | choice | Isolation / Bypass | Isolation or common bypass when no compression point meets constraints or during recovery wait. |
| Path After Protection Trip | ProtectionFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after trip. Bypass does not release latch and remains capacity/check limited. |
| Bypass Hydraulic Model | BypassHydraulicModel | choice | Expansion/Choked Flow / Fixed-Outlet-Density Pressure Difference / Pressure-Squared Difference | Select bypass hydraulics from valve/pipe data. Models differ in flow at equal differential. Fixed-outlet-density uses defined outlet even in reverse. |
| Bypass Full-Open Kv [m³/(h·bar⁰·⁵)] | BypassFullOpenKV | text | — | Whole-group common bypass full-open capacity from equipment data; not multiplied by unit count. |
| Bypass Critical Ratio xT | BypassXT | real | 0.7 | xT for expansion/choked flow; default is an estimate, prefer vendor full-open data. |
| Enable Bypass Check Action | EnableBypassCheck | check | On | Enabled check permits forward inlet-to-outlet flow only; disabled allows reverse flow under differential. |
| Bypass Cracking Differential [kPa] | BypassCrackingPressure | real | 0 | Bypass check opening differential, inlet minus outlet. Zero still requires forward-flow conditions. |
Advanced Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Custom Polytropic Exponent | PolytropicExponentMode | check | Auto | Enable to enter vendor/test polytropic exponent; otherwise derive it from gas properties and effective efficiency. |
| Polytropic Exponent n | PolytropicExponent | text | 1.3 | Vendor/test exponent converting polytropic head to ratio; also sets non-isothermal temperature unless a custom rise exponent is enabled. |
| Custom Temperature-Rise Exponent | TemperatureRiseMode | check | Linked | Non-isothermal polytropic maps only. Enables independent temperature-rise fitting. Default and custom relations differ, so equal exponents can produce different temperatures. |
| Temperature-Rise Exponent | TemperatureRiseRatio | text | 1.3 | Independent compression-section discharge-temperature exponent from vendor/test data. Outlet connection temperature also reflects internal pressure loss. |
Parameter Guidance
Select a Performance Map
Polytropic-head, adiabatic-head, and pressure ratio–flow maps each have an independent curve source. When switching map types, check the source and data for the newly selected type. Choose a curve source.
Both sources use four columns. The first two are speed in rpm and actual inlet volumetric flow per impeller in m³/h. The last two depend on map type.
| Map | Third column | Fourth |
|---|---|---|
| Polytropic head | Head (m) | Polytropic efficiency fraction |
| Adiabatic head | Head (m) | Adiabatic efficiency fraction |
| Pressure ratio–flow | Compression-section absolute ratio | Adiabatic efficiency fraction |
Each speed line needs at least two points in strictly increasing flow. First/last points define surge/stonewall boundaries and must match equipment data. Adiabatic maps need at least four distinct Q/N values across the map.
Enter 0.8 for 80% efficiency. Convert matching specific energy w from kJ/kg to J/kg, then divide by for head in m. Ratio maps use compression-section absolute pressure ratios.
Select Operating Control
Operating Control Mode selects the quantity controlled by speed. Control Source selects transient plan or signal commands.
- Fixed Speed uses known rpm, checked against map and maximum.
- Fixed Outlet/Inlet Pressure uses that port gauge pressure; Fixed Ratio uses outlet/inlet absolute pressure.
- Fixed Standard Flow/Power targets are per unit. Net flow uses global standards and excludes internal recycle. Identical parallel units sum group values: two units each supplying 5000 Nm³/h use a per-unit 5000 target.
Zero speed/power requests normal stop; zero net flow can still involve recycle. Target reachability depends on performance, network, and constraints.
Establish Initial Conditions
| Entry | Initial field/control |
|---|---|
| Steady-state or steady initialization | Panel state/count/target and constraints solve actual speed; fill panel values even for signal control. |
| Loaded new initial field | First frame uses loaded physical values; new control continues from loaded speed. |
| Continuation | Identity checks precede restoring plans, speed trajectory, and protection memory. |
For zero-speed startup, initialize stopped and schedule a future Run command.
Transient Control and Speed Ramps
Schedule rows set time, state, count, mode, and target together, with strictly increasing unique times. Past/start rows remain informational; panel establishes initial field. Normal rundown retains running units until zero speed, then changes stopped path.
Signals support setpoint only, run/stop only, or both. Run uses held 0/1. Setpoint units match mode; run-only still uses panel target.
Startup/stop times must be positive, default 120/60 s, defining zero-to-maximum and maximum-to-zero rates. Running changes use the same rates and continue from actual speed. Pressure/flow/power/ratio targets first solve a working-point speed, then ramp toward it.
For maximum 6000 rpm and 120 s startup, acceleration is 50 rpm/s; reaching 3000 rpm from zero takes 60 s if constraints permit.
Constraints, Anti-Surge, and Bypass
- Constraints. Maximum speed always applies; optional minimum speed, pressures, per-unit net flow/power, ratio, and outlet temperature constrain selection together. Enabled zero upper limits mean zero; disable to remove.
- Protection. Optional low suction/speed and high discharge/temperature trip after continuous transient delay; steady-state reports only. Low speed checks normal running. Command reset needs Off, release/wait, then fresh On.
- Thresholds. Low-value release exceeds trigger; high-value release is lower. Interrupted violations restart timing. Constraint recovery and protection release waits are separate.
- Anti-surge. Automatic recycle is ideal and cooled to inlet state. Speed avoidance can sacrifice target. Boundary-trip uses actual surge; external recycle requires a modeled loop. Default margin 0% puts control line on surge boundary.
- Bypass. Select isolation/bypass separately for normal stop, standby, and trip. Enter whole-path Kv and hydraulic/check settings. Check action permits only forward flow above cracking differential.
Common bypass uses the shut-off valve full-open hydraulics, zero shaft power, and actual-direction non-isothermal throttling. Models · Temperature
Polytropic Exponents
Default exponent follows gas properties and map efficiency. Enable custom polytropic exponent only with applicable data. Non-isothermal rise normally uses it; enable custom rise exponent only for independent temperature fitting. Check pressure, temperature, and power together.
View Results
| Check | Interpretation |
|---|---|
| Target/error | Compare target, actual, error, constraints. Noncompressing points/errors can show — while ports/bypass retain physical values. |
| Speed | Distinguish target point, ramp trajectory, and actual speed with phase/protection/constraints. |
| Flow/count | Map uses per-unit impeller actual flow; delivery uses net standard flow. Check requested/actual count and unit/group loads. |
| Pressure/temperature | Distinguish section and external port ratios; check map-consistent pressure, temperature, and power. |
| Surge/stop | Inspect margin, recycle, net flow, reason, bypass, and normal rundown versus trip. |
Professional Theory
Impeller Flow and Conservation
Net mass flow is conserved across ports; recycle adds impeller load. For actual count and group net/recycle flows at suction in m³/h, per-unit map flow and total impeller mass flow are
uses kg/m³ and kg/s. Zero net delivery can still have impeller flow and power during recycle.
Maps, Temperature Rise, and Power
Speed and per-unit impeller flow locate the map, jointly solved with network and constraints. Suction is ; internal discharge ; . Use absolute pressure and K. uses J/(kg·K), group shaft power W.
are map efficiency times correction factor; is mechanical efficiency. Correction and mechanical efficiency default to 1.
Polytropic Head Map
Map gives in m and efficiency. Inlet Z/T and exponent n convert head to ratio. Let ; default temperature uses the same exponent.
Automatic requires . BWRS uses ideal-gas k at inlet gas/T; pressure still determines density/Z. AGA8Gross uses an engineering equivalent ratio. Custom n must exceed 1.
With custom rise exponent , non-isothermal ; ratio and power retain polytropic-map relations.
Adiabatic Head Map
Map gives and efficiency. Evaluate at arithmetic midpoint suction/internal-discharge P/T and use mean . With , solve internal discharge P/T together.
Pressure Ratio–Flow Map
Map directly gives and adiabatic efficiency; . Temperature/power use inlet with . Efficiency corrects isentropic temperature rise. NASA
Compression Section to Outlet Connection
Fixed Ratio and ratio limits use external . Subtract internal losses from to obtain outlet pressure. Base loss uses net group actual flow; stonewall can add loss.
For non-isothermal delivery, sets actual outlet temperature for the same gas. Global isothermal uses global port temperature while map power remains.
Surge, Stonewall, and Recycle
At current speed, are per-unit impeller actual-flow boundaries on the low/high sides. For fractional control margin m,
Automatic recycle fills impeller flow to the control line. Speed avoidance shifts the point. Boundary-trip uses actual surge; external mode uses the modeled loop. Margin is monitoring-only in those two modes. Stonewall solves on the high-flow boundary with network-determined extra loss.
Ramps and Active Constraints
Acceleration/deceleration magnitudes are and . Speed holds at a feasible target; actual trajectories remain constrained by equipment and network.
Applicability and Limits
- Maps. Match vendor gas, suction, speed range, and flow definitions. Off-map speed uses similarity estimates subject to allowed ranges.
- Gas properties. biptGps supports the BWRS and AGA8Gross equations of state. Select a map type supported by the active equation. For AGA8Gross, use a polytropic-head or pressure ratio–flow map. Compression assumes single-phase gas.
- Anti-surge. Ideal recycle returns at inlet state. Model an external loop for real valve, cooler, and pipe dynamics.
Common Inspections
- Unexpected point/flow. Check map type/units/endpoints and count; distinguish impeller flow including recycle from net delivery.
- Pressure/temperature/power mismatch. Use absolute ratios; distinguish section/connection and unit/group; check head, efficiency, exponents, thermal mode, and recycle load.
- Unreachable target/speed. Check constraints and target/trajectory/actual speed, plus space between surge control and stonewall.
- No delivery or stopped flow. Inspect path, recycle, and bypass. Closed discharge check can coexist with recycle/power; stopped bypass can flow under network differential.