Centrifugal Compressor

Uses maps, suction state, and network conditions to solve pressure, flow, temperature, speed, and shaft power for compression, parallel loading, and anti-surge studies.

Component Appearance and Location​

Expand Compressor in the component library on the left and find "Centrifugal Compressor".

Created with Fabric.js 5.3.0

Ports and Connections​

PortTypeDirectionUse
0FLUIDInputSuction network
1FLUIDOutputDischarge network

Compression flows inlet to outlet. Stopped flow depends on bypass/check settings. Bind signals using a measurement instrument or actuator.

Modeling Steps​

  1. Connect suction/discharge.
  2. In Equipment Specifications, select the map type and source. Use Edit Local Curve to enter points on the component or Reference Curve Database to select a named map of the same type.
  3. Set initial state/count/mode/target and maximum speed.
  4. Configure constraints, protection, anti-surge, and stopped paths. Check steady-state before transient plans/signals.
  5. Compare targets, actual values, constraints, loads, compression, recycle, and bypass.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Parameter VersionCentrifugalCompressorConfigVersionchoice2No description.
Performance Map TypeHeadMapTypechoicePolytropic Head Map / Adiabatic Head Map / Pressure Ratio–Flow MapMatch vendor map: polytropic head/efficiency or adiabatic head/ratio with adiabatic efficiency. Columns are speed, per-unit impeller inlet actual flow, head/absolute ratio, efficiency.
Polytropic Head MapCurveLibraryHeadMapNamechoice__UNSELECTED__Select matching vendor/test map: speed, per-unit impeller flow, head in m, fractional efficiency. Endpoints define surge/stonewall. Off-map speed uses similarity, subject to equipment limits.
Adiabatic Head MapCurveLibraryAdiabaticHeadMapNamechoice__UNSELECTED__Select matching vendor/test map: speed, per-unit impeller flow, head in m, fractional efficiency. Endpoints define surge/stonewall. Off-map speed uses similarity, subject to equipment limits.
Pressure Ratio–Flow MapCurveLibraryPressureRatioMapNamechoice__UNSELECTED__Select a shared pressure-ratio map. The columns are speed in rpm, per-unit impeller inlet volumetric flow at operating conditions in m³/h, absolute pressure ratio, and adiabatic efficiency as a fraction. The endpoints of each speed line mark the surge and stonewall limits.

Initial Conditions

NamekeyTypeDefault / OptionsDescription
Initial Operating StateStatuschoiceRun / StopSteady-state and new transient initialization use panel requests/settings. Later plans/signals govern, subject to constraints/protection.
Parallel Running Units [units]NRNinteger1Positive integer count of identical parallel units; use state to stop. Flow/power are per unit and summed by count; pressure, ratio, and common bypass are not multiplied.
Operating Control ModeControlTargetchoiceFixed Speed / Fixed Outlet Pressure / Fixed Inlet Pressure / Fixed Standard Flow / Fixed Shaft Power / Fixed Pressure RatioSelect the quantity maintained through speed adjustment, subject to maps/network/constraints. Panel values establish steady-state/initial fields; loaded fields retain physical state before new control.
Speed Setpoint [rpm]SpeedSetpointtext4500Requested rpm, subject to performance and constraints. Zero requests normal stop.
Outlet Pressure Setpoint [MPa(g)]DischargePressureSetpointtext1.5Outlet-connection gauge target, jointly determined with network and constraints.
Inlet Pressure Setpoint [MPa(g)]SuctionPressureSetpointtext1Inlet-connection gauge target, jointly determined with network and constraints.
Per-Unit Net Standard Flow Setpoint [Nm³/h]FlowrateSetpointtext1000Per-unit net standard delivery excluding internal recycle; global references apply. Group sums by count. Zero remains Run and can use recycle for zero net delivery.
Per-Unit Shaft Power Setpoint [kW]PowerSetpointtext50Per-unit input shaft-power target, summed by count; not electrical consumption. Zero requests normal stop.
Pressure Ratio SetpointPressureRatioSetpointtext1.5Finite positive external absolute pressure ratio, including compression and internal loss. Never divide gauge pressures; performance/constraints determine reachability.

Control Source and Operating Schedule

NamekeyTypeDefault / OptionsDescription
Control SourceControlModechoiceOperating Schedule / Signal ControlTransient only. Schedules use panel initial state/future events; signals apply after physical initialization. Switching sources retains standby settings.
Signal Control ContentsSignalControlModechoiceSetpoint Only / Run/Stop Only / Run/Stop and SetpointSignals control setpoint, run/stop, or both. Run-only retains panel target. Held 0 means Stop, 1 permits Run subject to protection/eligibility.
Startup Time [s]StartupDurationreal120Positive zero-to-maximum-speed reference time. Acceleration rate is maximum speed/time for startup and adjustments; actual duration depends on speed change.
Stop Time [s]ShutdownDurationreal60Positive maximum-to-zero reference time. Normal stop/deceleration uses maximum speed/time and ends at target/zero. Protection uses separate trip action.
Operating ScheduleOperatingPlantableConfigure one row at a timeRows activate state/count/mode/target together at unique increasing future times. Past/start rows do not execute. Flow/power are per unit. Steady-state/signal mode ignores this table. Commands continue from actual speed using startup/stop rates and operating constraints.
Operating Schedule / Effective TimeOperatingPlan.timedatetime2025-01-01 00:00:00Valid datetime; past/start rows remain informational, future rows activate at their times.
Operating Schedule / Operating StateOperatingPlan.statuschoiceRun / StopState applies with count/target; do not use zero count to stop.
Operating Schedule / Parallel Running Units [units]OperatingPlan.nrninteger1Positive integer, switched immediately. Normal rundown retains previous actual units.
Operating Schedule / Operating Control ModeOperatingPlan.controlTargetchoiceFixed Speed (rpm) / Fixed Outlet Pressure (MPa(g)) / Fixed Inlet Pressure (MPa(g)) / Fixed Standard Flow (Nm³/h, per unit) / Fixed Shaft Power (kW, per unit) / Fixed Ratio (dimensionless)Mode for this row; enter the target in its displayed units.
Operating Schedule / Setpoint (Units Depend on Mode)OperatingPlan.setpointtext—Target according to row mode: per-unit flow/power, gauge pressure, or absolute pressure ratio.

Operating Constraints and Protection

NamekeyTypeDefault / OptionsDescription
Enable Minimum Normal SpeedEnableMinimumSpeedRPMcheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Normal Speed [rpm]MinimumSpeedRPMtext—Minimum normal actual speed; waived during finite startup/normal stop, active during normal running/adjustments.
Maximum Allowable Speed [rpm]MaximumSpeedRPMtext—Positive equipment maximum speed, always active and the reference for all normal speed ramp rates.
Enable Minimum Inlet PressureEnableMinimumSuctionPressurecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Operating Inlet Pressure [MPa(g)]MinimumSuctionPressuretext—Minimum inlet gauge pressure with positive converted absolute pressure. Always active during startup/stop; independent of protection thresholds.
Enable Maximum Outlet PressureEnableMaximumOutletPressurecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating Outlet Pressure [MPa(g)]MaximumOutletPressuretext—Maximum outlet gauge pressure with positive absolute pressure. Always active; independent of high-pressure protection thresholds.
Enable Per-Unit Minimum Net Standard FlowEnableMinimumFlowratecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Minimum Net Standard Flow [Nm³/h]MinimumFlowratetext—Per-unit minimum net standard flow, excluding recycle, at global standards. Zero is zero minimum. Waived in finite startup/normal stop; does not replace anti-surge.
Enable Per-Unit Maximum Net Standard FlowEnableMaximumFlowratecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Maximum Net Standard Flow [Nm³/h]MaximumFlowratetext—Per-unit maximum net standard flow excluding recycle. Zero is a real zero limit; disable to remove. Active during startup/stop.
Enable Per-Unit Minimum Shaft PowerEnableMinimumPowercheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Minimum Shaft Power [kW]MinimumPowertext—Per-unit minimum shaft power, not electrical power. Zero is allowed. Waived in finite startup/normal stop; group totals use actual count.
Enable Per-Unit Maximum Shaft PowerEnableMaximumPowercheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Maximum Shaft Power [kW]MaximumPowertext—Per-unit maximum shaft power. Zero is a real zero limit; disable to remove. Always active; group totals use actual count.
Enable Minimum Operating RatioEnableMinimumPressureRatiocheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Operating RatioMinimumPressureRatiotext—Positive minimum external absolute ratio, possibly below 1. Waived in finite startup/normal stop; never use gauge ratios.
Enable Maximum Operating RatioEnableMaximumPressureRatiocheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating RatioMaximumPressureRatiotext—Positive maximum external absolute ratio, possibly below 1; active during startup/stop.
Enable Maximum Outlet TemperatureEnableMaximumOutletTemperaturecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating Outlet Temperature [℃]MaximumOutletTemperaturetext—Actual outlet temperature upper limit, always active. Isothermal mode checks global temperature.
Constraint Recovery Wait [s]ConstraintRecoveryDelayreal0Standby recovery needs continuous Run and feasibility for this wait; interruption restarts it. Zero still requires eligibility; excludes startup. Transient only.
Enable Low Inlet Pressure ProtectionEnableTripLowSuctionPressurecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
Low Inlet Pressure Trigger [MPa(g)]TripLowSuctionPressuretext—Triggers at/below actual inlet gauge pressure. Steady-state warns without timing/latching; transient continuous delay causes immediate trip without normal rundown.
Low Inlet Pressure Release [MPa(g)]TripLowSuctionPressureReleasetext—Release strictly above trigger, reached on its safe side. Release also needs wait, reset mode, Run, and feasibility before restart.
Low Inlet Pressure Trigger Delay [s]TripLowSuctionPressureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Enable High Outlet Pressure ProtectionEnableTripHighDischargePressurecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
High Outlet Pressure Trigger [MPa(g)]TripHighDischargePressuretext—Triggers at/above outlet gauge pressure. Steady-state warns only; transient continuous delay trips without normal rundown.
High Outlet Pressure Release [MPa(g)]TripHighDischargePressureReleasetext—Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply.
High Outlet Pressure Trigger Delay [s]TripHighDischargePressureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Enable High Outlet Temperature ProtectionEnableTripHighDischargeTemperaturecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
High Outlet Temperature Trigger [℃]TripHighDischargeTemperaturetext—Triggers at/above actual outlet temperature. Steady-state warns only; transient delay trips without normal rundown.
High Outlet Temperature Release [℃]TripHighDischargeTemperatureReleasetext—Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply.
High Outlet Temperature Trigger Delay [s]TripHighDischargeTemperatureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Enable Low Speed ProtectionEnableTripLowSpeedcheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
Low Speed Trigger [rpm]TripLowSpeedtext—Triggers at/below actual speed after continuous delay, only in normal running/adjustment. Startup/normal stop exempt. Steady-state warns only.
Low Speed Release [rpm]TripLowSpeedReleasetext—Release strictly above trigger. Wait/reset/Run/feasibility also apply. When stopped, evaluate release against the proposed restart-point speed.
Low Speed Trigger Delay [s]TripLowSpeedDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Protection Reset ModeProtectionResetModechoiceRun/Stop Command Reset / Automatic ResetCommand reset requires Off, satisfied release/wait, then fresh Run. Automatic reset requires continuous release/wait. Restart still requires Run and feasibility.
Protection Release Wait [s]TripRecoveryDelayreal0All latched causes must continuously satisfy release for this wait; interruption restarts it. Zero still needs release; reset/Run/feasibility govern restart. Transient only.

Anti-Surge Settings

NamekeyTypeDefault / OptionsDescription
Anti-Surge ModeAntiSurgeModechoiceAutomatic Recycle / Speed-Based Surge Avoidance / Boundary Trip / External Recycle SystemAutomatic recycle is ideal and cooled to inlet, without real valve capacity/time. Speed avoidance can limit target. Boundary-trip uses actual surge; external recycle uses connected network.
Anti-Surge Control Margin [%]SurgeControlMarginreal0Margin above same-speed surge flow; zero puts control line on boundary. Used for automatic recycle/speed avoidance, monitoring only for boundary-trip/external recycle. Actual margin is reported.

Bypass Settings

NamekeyTypeDefault / OptionsDescription
Enable Equipment BypassEnableBypasscheckOffEnables common inlet-to-outlet bypass with separate normal-stop/standby/trip path selection. Internal anti-surge recycle is separate.
Path After Normal StopStoppedFlowDispositionchoiceIsolation / BypassIsolation or bypass after normal stop. Flow depends on network differential, common capacity, and check settings.
Path During Constraint StandbyInfeasibleFlowDispositionchoiceIsolation / BypassIsolation or common bypass when no compression point meets constraints or during recovery wait.
Path After Protection TripProtectionFlowDispositionchoiceIsolation / BypassIsolation or bypass after trip. Bypass does not release latch and remains capacity/check limited.
Bypass Hydraulic ModelBypassHydraulicModelchoiceExpansion/Choked Flow / Fixed-Outlet-Density Pressure Difference / Pressure-Squared DifferenceSelect bypass hydraulics from valve/pipe data. Models differ in flow at equal differential. Fixed-outlet-density uses defined outlet even in reverse.
Bypass Full-Open Kv [m³/(h·bar⁰·⁵)]BypassFullOpenKVtext—Whole-group common bypass full-open capacity from equipment data; not multiplied by unit count.
Bypass Critical Ratio xTBypassXTreal0.7xT for expansion/choked flow; default is an estimate, prefer vendor full-open data.
Enable Bypass Check ActionEnableBypassCheckcheckOnEnabled check permits forward inlet-to-outlet flow only; disabled allows reverse flow under differential.
Bypass Cracking Differential [kPa]BypassCrackingPressurereal0Bypass check opening differential, inlet minus outlet. Zero still requires forward-flow conditions.

Advanced Settings

NamekeyTypeDefault / OptionsDescription
Custom Polytropic ExponentPolytropicExponentModecheckAutoEnable to enter vendor/test polytropic exponent; otherwise derive it from gas properties and effective efficiency.
Polytropic Exponent nPolytropicExponenttext1.3Vendor/test exponent converting polytropic head to ratio; also sets non-isothermal temperature unless a custom rise exponent is enabled.
Custom Temperature-Rise ExponentTemperatureRiseModecheckLinkedNon-isothermal polytropic maps only. Enables independent temperature-rise fitting. Default and custom relations differ, so equal exponents can produce different temperatures.
Temperature-Rise ExponentTemperatureRiseRatiotext1.3Independent compression-section discharge-temperature exponent from vendor/test data. Outlet connection temperature also reflects internal pressure loss.

Parameter Guidance​

Select a Performance Map​

Polytropic-head, adiabatic-head, and pressure ratio–flow maps each have an independent curve source. When switching map types, check the source and data for the newly selected type. Choose a curve source.

Both sources use four columns. The first two are speed in rpm and actual inlet volumetric flow per impeller in m³/h. The last two depend on map type.

MapThird columnFourth
Polytropic headHead (m)Polytropic efficiency fraction
Adiabatic headHead (m)Adiabatic efficiency fraction
Pressure ratio–flowCompression-section absolute ratioAdiabatic efficiency fraction

Each speed line needs at least two points in strictly increasing flow. First/last points define surge/stonewall boundaries and must match equipment data. Adiabatic maps need at least four distinct Q/N values across the map.

Enter 0.8 for 80% efficiency. Convert matching specific energy w from kJ/kg to J/kg, then divide by g=9.80665 m/s2g=9.80665\,\mathrm{m/s^2} for head in m. Ratio maps use compression-section absolute pressure ratios.

Select Operating Control​

Operating Control Mode selects the quantity controlled by speed. Control Source selects transient plan or signal commands.

  • Fixed Speed uses known rpm, checked against map and maximum.
  • Fixed Outlet/Inlet Pressure uses that port gauge pressure; Fixed Ratio uses outlet/inlet absolute pressure.
  • Fixed Standard Flow/Power targets are per unit. Net flow uses global standards and excludes internal recycle. Identical parallel units sum group values: two units each supplying 5000 Nm³/h use a per-unit 5000 target.

Zero speed/power requests normal stop; zero net flow can still involve recycle. Target reachability depends on performance, network, and constraints.

Establish Initial Conditions​

EntryInitial field/control
Steady-state or steady initializationPanel state/count/target and constraints solve actual speed; fill panel values even for signal control.
Loaded new initial fieldFirst frame uses loaded physical values; new control continues from loaded speed.
ContinuationIdentity checks precede restoring plans, speed trajectory, and protection memory.

For zero-speed startup, initialize stopped and schedule a future Run command.

Transient Control and Speed Ramps​

Schedule rows set time, state, count, mode, and target together, with strictly increasing unique times. Past/start rows remain informational; panel establishes initial field. Normal rundown retains running units until zero speed, then changes stopped path.

Signals support setpoint only, run/stop only, or both. Run uses held 0/1. Setpoint units match mode; run-only still uses panel target.

Startup/stop times must be positive, default 120/60 s, defining zero-to-maximum and maximum-to-zero rates. Running changes use the same rates and continue from actual speed. Pressure/flow/power/ratio targets first solve a working-point speed, then ramp toward it.

For maximum 6000 rpm and 120 s startup, acceleration is 50 rpm/s; reaching 3000 rpm from zero takes 60 s if constraints permit.

Constraints, Anti-Surge, and Bypass​

  • Constraints. Maximum speed always applies; optional minimum speed, pressures, per-unit net flow/power, ratio, and outlet temperature constrain selection together. Enabled zero upper limits mean zero; disable to remove.
  • Protection. Optional low suction/speed and high discharge/temperature trip after continuous transient delay; steady-state reports only. Low speed checks normal running. Command reset needs Off, release/wait, then fresh On.
  • Thresholds. Low-value release exceeds trigger; high-value release is lower. Interrupted violations restart timing. Constraint recovery and protection release waits are separate.
  • Anti-surge. Automatic recycle is ideal and cooled to inlet state. Speed avoidance can sacrifice target. Boundary-trip uses actual surge; external recycle requires a modeled loop. Default margin 0% puts control line on surge boundary.
  • Bypass. Select isolation/bypass separately for normal stop, standby, and trip. Enter whole-path Kv and hydraulic/check settings. Check action permits only forward flow above cracking differential.

Common bypass uses the shut-off valve full-open hydraulics, zero shaft power, and actual-direction non-isothermal throttling. Models · Temperature

Polytropic Exponents​

Default exponent follows gas properties and map efficiency. Enable custom polytropic exponent only with applicable data. Non-isothermal rise normally uses it; enable custom rise exponent only for independent temperature fitting. Check pressure, temperature, and power together.

View Results​

CheckInterpretation
Target/errorCompare target, actual, error, constraints. Noncompressing points/errors can show — while ports/bypass retain physical values.
SpeedDistinguish target point, ramp trajectory, and actual speed with phase/protection/constraints.
Flow/countMap uses per-unit impeller actual flow; delivery uses net standard flow. Check requested/actual count and unit/group loads.
Pressure/temperatureDistinguish section and external port ratios; check map-consistent pressure, temperature, and power.
Surge/stopInspect margin, recycle, net flow, reason, bypass, and normal rundown versus trip.

Professional Theory​

Impeller Flow and Conservation​

Net mass flow is conserved across ports; recycle adds impeller load. For actual count NrunN_{\mathrm{run}} and group net/recycle flows Qnet,in,Qrec,inQ_{\mathrm{net,in}},Q_{\mathrm{rec,in}} at suction in m³/h, per-unit map flow and total impeller mass flow are

Qimp,unit=Qnet,in+Qrec,inNrun,m˙imp=ρinNrunQimp,unit3600.Q_{\mathrm{imp,unit}}=\frac{Q_{\mathrm{net,in}}+Q_{\mathrm{rec,in}}}{N_{\mathrm{run}}}, \qquad \dot m_{\mathrm{imp}}=\rho_{\mathrm{in}}\frac{N_{\mathrm{run}}Q_{\mathrm{imp,unit}}}{3600}.

ρin\rho_{\mathrm{in}} uses kg/m³ and m˙imp\dot m_{\mathrm{imp}} kg/s. Zero net delivery can still have impeller flow and power during recycle.

Maps, Temperature Rise, and Power​

Speed and per-unit impeller flow locate the map, jointly solved with network and constraints. Suction is pin,Tinp_{\mathrm{in}},T_{\mathrm{in}}; internal discharge pc,Tcp_{\mathrm{c}},T_{\mathrm{c}}; rc=pc/pinr_{\mathrm{c}}=p_{\mathrm{c}}/p_{\mathrm{in}}. Use absolute pressure and K. RsR_s uses J/(kg·K), group shaft power W.

ηp,ηa\eta_p,\eta_a are map efficiency times correction factor; ηm\eta_m is mechanical efficiency. Correction and mechanical efficiency default to 1.

Polytropic Head Map​

Map gives HpH_p in m and efficiency. Inlet Z/T and exponent n convert head to ratio. Let b=(n−1)/nb=(n-1)/n; default temperature uses the same exponent.

rc=(1+b gHpZinRsTin)1/b,Tc=Tinrcb,Pshaft=m˙impgHpηpηm.r_{\mathrm{c}}=\left(1+\frac{b\,gH_p}{Z_{\mathrm{in}}R_sT_{\mathrm{in}}}\right)^{1/b}, \qquad T_{\mathrm{c}}=T_{\mathrm{in}}r_{\mathrm{c}}^b, \qquad P_{\mathrm{shaft}}=\frac{\dot m_{\mathrm{imp}}gH_p}{\eta_p\eta_m}.

Automatic b=(k−1)/(kηp)b=(k-1)/(k\eta_p) requires 0<b<10<b<1. BWRS uses ideal-gas k at inlet gas/T; pressure still determines density/Z. AGA8Gross uses an engineering equivalent ratio. Custom n must exceed 1.

With custom rise exponent nT>1n_T>1, non-isothermal Tc=Tinrc(nT−1)/(nTηp)T_{\mathrm{c}}=T_{\mathrm{in}}r_{\mathrm{c}}^{(n_T-1)/(n_T\eta_p)}; ratio and power retain polytropic-map relations.

Adiabatic Head Map​

Map gives HaH_a and efficiency. Evaluate kmk_m at arithmetic midpoint suction/internal-discharge P/T and use mean Zˉ\bar Z. With am=(km−1)/kma_m=(k_m-1)/k_m, solve internal discharge P/T together.

rc=(1+am gHaZˉRsTin)1/am,Tc=Tin(1+rcam−1ηa),Pshaft=m˙impgHaηaηm.r_{\mathrm{c}}=\left(1+\frac{a_m\,gH_a}{\bar ZR_sT_{\mathrm{in}}}\right)^{1/a_m}, \qquad T_{\mathrm{c}}=T_{\mathrm{in}}\left(1+\frac{r_{\mathrm{c}}^{a_m}-1}{\eta_a}\right), \qquad P_{\mathrm{shaft}}=\frac{\dot m_{\mathrm{imp}}gH_a}{\eta_a\eta_m}.

Pressure Ratio–Flow Map​

Map directly gives rcr_{\mathrm{c}} and adiabatic efficiency; pc=pinrcp_{\mathrm{c}}=p_{\mathrm{in}}r_{\mathrm{c}}. Temperature/power use inlet kin,Zink_{\mathrm{in}},Z_{\mathrm{in}} with ain=(kin−1)/kina_{\mathrm{in}}=(k_{\mathrm{in}}-1)/k_{\mathrm{in}}. Efficiency corrects isentropic temperature rise. NASA

Tc=Tin(1+rcain−1ηa),Pshaft=m˙impZinRsTinainηaηm(rcain−1).T_{\mathrm{c}}=T_{\mathrm{in}}\left(1+\frac{r_{\mathrm{c}}^{a_{\mathrm{in}}}-1}{\eta_a}\right), \qquad P_{\mathrm{shaft}}= \frac{\dot m_{\mathrm{imp}}Z_{\mathrm{in}}R_sT_{\mathrm{in}}}{a_{\mathrm{in}}\eta_a\eta_m} \left(r_{\mathrm{c}}^{a_{\mathrm{in}}}-1\right).

Compression Section to Outlet Connection​

Fixed Ratio and ratio limits use external pout/pinp_{\mathrm{out}}/p_{\mathrm{in}}. Subtract internal losses from pcp_{\mathrm{c}} to obtain outlet pressure. Base loss uses net group actual flow; stonewall can add loss.

For non-isothermal delivery, h(pout,Tout)=h(pc,Tc)h(p_{\mathrm{out}},T_{\mathrm{out}})=h(p_{\mathrm{c}},T_{\mathrm{c}}) sets actual outlet temperature for the same gas. Global isothermal uses global port temperature while map power remains.

Surge, Stonewall, and Recycle​

At current speed, Qs,QswQ_{\mathrm{s}},Q_{\mathrm{sw}} are per-unit impeller actual-flow boundaries on the low/high sides. For fractional control margin m,

Qctrl=Qs(1+m).Q_{\mathrm{ctrl}}=Q_{\mathrm{s}}(1+m).

Automatic recycle fills impeller flow to the control line. Speed avoidance shifts the point. Boundary-trip uses actual surge; external mode uses the modeled loop. Margin is monitoring-only in those two modes. Stonewall solves on the high-flow boundary with network-determined extra loss.

Ramps and Active Constraints​

Acceleration/deceleration magnitudes are Nmax⁡/TstartN_{\max}/T_{\mathrm{start}} and Nmax⁡/TstopN_{\max}/T_{\mathrm{stop}}. Speed holds at a feasible target; actual trajectories remain constrained by equipment and network.

Applicability and Limits​

  • Maps. Match vendor gas, suction, speed range, and flow definitions. Off-map speed uses similarity estimates subject to allowed ranges.
  • Gas properties. biptGps supports the BWRS and AGA8Gross equations of state. Select a map type supported by the active equation. For AGA8Gross, use a polytropic-head or pressure ratio–flow map. Compression assumes single-phase gas.
  • Anti-surge. Ideal recycle returns at inlet state. Model an external loop for real valve, cooler, and pipe dynamics.

Common Inspections​

  • Unexpected point/flow. Check map type/units/endpoints and count; distinguish impeller flow including recycle from net delivery.
  • Pressure/temperature/power mismatch. Use absolute ratios; distinguish section/connection and unit/group; check head, efficiency, exponents, thermal mode, and recycle load.
  • Unreachable target/speed. Check constraints and target/trajectory/actual speed, plus space between surge control and stonewall.
  • No delivery or stopped flow. Inspect path, recycle, and bypass. Closed discharge check can coexist with recycle/power; stopped bypass can flow under network differential.