Universal Compressor
For system-level studies without complete performance maps, this compressor selects operating points within equipment limits and calculates pressure rise, flow, temperature, and shaft power. Use a Centrifugal Compressor for map-based speed, surge, and recycle analysis.
Component Appearance and Location
Expand Compressor in the component library on the left and find "Universal Compressor".
Ports and Connections
Gas ports 0 and 1 are inlet/outlet; normal compression permits forward flow only. Bind measurements, setpoints, or run commands with a measurement instrument or actuator. Bypass check settings determine reverse-flow permission.
Parameter List
Compression Process
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Compression Process Model | ThermodynamicPath | choice | Isothermal / Adiabatic / Polytropic / Empirical | Select compression/power relation. Global isothermal fixes gas temperature globally while power follows this process. |
| Isothermal Efficiency | IsothermalEfficiency | real | 0.8 | Reversible isothermal work divided by actual input work; use vendor/test efficiency for isothermal shaft power. |
| Adiabatic Efficiency | AdiabaticEfficiency | real | 0.8 | Adiabatic shaft-power efficiency, also affecting non-isothermal discharge temperature. Match process/properties and vendor data. Heat capacity ratio normally uses properties; GPSA is optional in advanced settings. |
| Polytropic Efficiency | PolytropicEfficiency | real | 0.8 | Polytropic shaft-power efficiency, also affecting non-isothermal discharge temperature; match equipment/process/properties. |
| Empirical Power Coefficient K1 [kW/(m³/h)] | EmpiricalK1 | real | 0.15 | Empirical power coefficient using this group reference P/T volume flow. K1≥K2>0; convert external coefficient units. |
| Empirical Power Coefficient K2 [kW/(m³/h)] | EmpiricalK2 | real | 0.15 | Empirical power coefficient using this group reference P/T volume flow. K1≥K2>0; convert external coefficient units. |
| Empirical Power Exponent K3 | EmpiricalK3 | real | 0.23 | Positive pressure-ratio exponent for empirical power, independent of temperature exponent. |
| Temperature-Rise Exponent | EmpiricalTemperatureIndex | real | 1.3 | Empirical discharge-temperature exponent ≥1; 1 means zero rise but retains empirical power. Non-isothermal only; use test/vendor temperature data. |
| Coefficient Reference Pressure [kPa(a)] | EmpiricalReferencePressureKPa | real | 101.325 | Absolute reference pressure for coefficient volume flow, possibly different from global standards. Stored with coefficients; changing it does not convert coefficients. |
| Coefficient Reference Temperature [℃] | EmpiricalReferenceTemperatureC | real | 20 | Reference temperature from coefficient data, possibly different from global standards. Changing it does not convert coefficients. |
Initial Conditions
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Initial Operating State | Status | choice | Run / Stop | Steady-state and new transient initialization use panel requests/settings. Later plans/signals govern, subject to constraints/protection. |
| Parallel Running Units [units] | NRN | integer | 1 | Positive integer count of identical parallel units; use state to stop. Flow/power are per unit and summed by count; pressure, ratio, and common bypass are not multiplied. |
| Operating Control Mode | ControlTarget | choice | Fixed Inlet Pressure / Fixed Outlet Pressure / Fixed Pressure Rise / Fixed Standard Flow / Fixed Shaft Power / Fixed Pressure Ratio | Select controlled quantity subject to equipment/network/constraints. Plans can switch mode; signals use panel mode. |
| Outlet Pressure Setpoint [MPa(g)] | DischargePressureSetpoint | real | 2 | Outlet-connection gauge target, jointly determined with network and constraints. |
| Inlet Pressure Setpoint [MPa(g)] | SuctionPressureSetpoint | real | 1 | Inlet-connection gauge target, jointly determined with network and constraints. |
| Pressure Rise Setpoint [MPa] | PressureDiffSetpoint | real | 1 | Outlet-minus-inlet pressure target, subject to capacity, network, and constraints. |
| Per-Unit Net Standard Flow Setpoint [Nm³/h] | FlowrateSetpoint | real | 1000 | Per-unit net standard delivery excluding recycle, at global standards, summed by count. Zero stops compression but is not an explicit Stop needed for reset. |
| Per-Unit Shaft Power Setpoint [kW] | PowerSetpoint | real | 1000 | Per-unit shaft-power request, not electrical consumption. Zero stops compression but does not replace explicit Stop for reset. |
| Pressure Ratio Setpoint | PressureRatioSetpoint | real | 2 | External absolute pressure ratio ≥1; 1 requests zero rise. Never use gauge ratios. |
Control Source and Operating Schedule
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Control Source | ControlMode | choice | Operating Schedule / Signal Control | Transient only. Schedules use panel initial state/future events; signals apply after physical initialization. Switching sources retains standby settings. |
| Signal Control Contents | SignalControlMode | choice | Setpoint Only / Run/Stop Only / Run/Stop and Setpoint | Signals control setpoint, run/stop, or both. Run-only retains panel target. Held 0 means Stop, 1 permits Run subject to protection/eligibility. |
| Setpoint Transition Time [s] | SetpointRampTime | real | 0 | Same-mode running target ramp duration from current reached value. Zero switches immediately; later plans can interrupt. Mode changes, Stop, and restart are immediate. Not used by signals. |
| Operating Schedule | OperatingPlan | table | Configure one row at a time | State/count/mode/target activate together at unique increasing future times; past/start rows remain informational. Flow/power are per unit. Steady-state/signal modes do not execute this table. |
| Operating Schedule / Effective Time | OperatingPlan.time | datetime | 2026-01-01 00:00:00 | Target activation time, not ramp completion. |
| Operating Schedule / Operating State | OperatingPlan.status | choice | Run / Stop | Compressor operating state. |
| Operating Schedule / Parallel Running Units [units] | OperatingPlan.nrn | integer | 1 | At least 1 unit, including Off rows. |
| Operating Schedule / Operating Control Mode | OperatingPlan.controlTarget | choice | Fixed Inlet Pressure (MPa(g)) / Fixed Outlet Pressure (MPa(g)) / Fixed Pressure Rise (MPa) / Fixed Standard Flow (Nm³/h, per unit) / Fixed Shaft Power (kW, per unit) / Fixed Ratio (dimensionless) | Mode for this row; enter the target in its displayed units. |
| Operating Schedule / Setpoint (Units Depend on Mode) | OperatingPlan.setpoint | real | 2 | Target according to row mode: per-unit flow/power, gauge pressure, or absolute pressure ratio. |
Operating Constraints and Protection
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Minimum Inlet Pressure | EnableMinimumSuctionPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Inlet Pressure [MPa(g)] | MinimumSuctionPressure | real | 0 | Minimum inlet gauge pressure with positive converted absolute pressure. Always active during startup/stop; independent of protection thresholds. |
| Enable Maximum Outlet Pressure | EnableMaximumOutletPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Outlet Pressure [MPa(g)] | MaximumOutletPressure | real | 3 | Maximum outlet gauge pressure with positive absolute pressure. Always active; independent of high-pressure protection thresholds. |
| Enable Per-Unit Minimum Net Standard Flow | EnableMinimumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Net Standard Flow [Nm³/h] | MinimumFlowrate | real | 0 | Per-unit minimum net standard flow at global standards, summed by actual count, excluding recycle. Zero is zero minimum; does not replace anti-surge. |
| Enable Per-Unit Maximum Net Standard Flow | EnableMaximumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Net Standard Flow [Nm³/h] | MaximumFlowrate | real | 10000 | Per-unit maximum net standard flow excluding recycle. Zero is a real zero limit; disable to remove. Active during startup/stop. |
| Enable Per-Unit Minimum Shaft Power | EnableMinimumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Shaft Power [kW] | MinimumPower | real | 1 | Per-unit minimum shaft power, not electrical power; zero minimum allowed. Sum by actual count. |
| Enable Per-Unit Maximum Shaft Power | EnableMaximumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Shaft Power [kW] | MaximumPower | real | 1000 | Per-unit maximum shaft power. Zero is a real zero limit; disable to remove. Always active; group totals use actual count. |
| Enable Minimum Operating Ratio | EnableMinimumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Ratio | MinimumPressureRatio | real | 1 | Minimum absolute discharge/suction ratio ≥1; never use gauge pressures. |
| Enable Maximum Operating Ratio | EnableMaximumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Ratio | MaximumPressureRatio | real | 10 | Maximum absolute ratio >1, also active during startup/stop. |
| Constraint Recovery Wait [s] | ConstraintRecoveryDelay | real | 0 | Standby recovery needs continuous Run and feasibility for this wait; interruption restarts it. Zero still requires eligibility; excludes startup. Transient only. |
| Enable Low Inlet Pressure Protection | EnableLowSuctionTrip | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| Low Inlet Pressure Trigger [MPa(g)] | LowSuctionTripPressure | text | — | Low inlet gauge trigger. Steady-state only warns without timing/latching/trip; transients protect at accepted valid states. |
| Low Inlet Pressure Release [MPa(g)] | LowSuctionResetPressure | text | — | Release strictly above trigger, reached on its safe side. Release also needs wait, reset mode, Run, and feasibility before restart. |
| Enable High Outlet Pressure Protection | EnableHighDischargeTrip | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| High Outlet Pressure Trigger [MPa(g)] | HighDischargeTripPressure | text | — | High outlet gauge trigger. Steady-state only warns; transients protect at accepted valid states. |
| High Outlet Pressure Release [MPa(g)] | HighDischargeResetPressure | text | — | Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply. |
| Protection Reset Mode | TripResetMode | choice | Run/Stop Command Reset / Automatic Reset | Command reset needs Off then fresh Run after release/wait; early Run expires without queuing. Automatic reset retries after continuous release/wait. Run and feasibility still apply; without a run-command source, command reset cannot occur. |
| Protection Release Wait [s] | TripRecoveryDelay | real | 0 | All latched causes must continuously satisfy release for this wait; interruption restarts it. Zero still needs release; reset/Run/feasibility govern restart. Transient only. |
Bypass Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Equipment Bypass | EnableBypass | check | Off | Allows separate common bypass paths during stop/standby/trip. Not anti-surge recycle or continuously modulated bypass opening. |
| Path After Normal Stop | StoppedFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after normal stop. Flow depends on network differential, common capacity, and check settings. |
| Path During Constraint Standby | InfeasibleFlowDisposition | choice | Isolation / Bypass | Isolation or common bypass when no compression point meets constraints or during recovery wait. |
| Path After Protection Trip | ProtectionFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after trip. Bypass does not release latch and remains capacity/check limited. |
| Bypass Hydraulic Model | BypassHydraulicModel | choice | Expansion/Choked Flow / Fixed-Outlet-Density Pressure Difference / Pressure-Squared Difference | Select bypass hydraulics from valve/pipe data. Models differ in flow at equal differential. Fixed-outlet-density uses defined outlet even in reverse. |
| Bypass Full-Open Kv [m³/(h·bar⁰·⁵)] | BypassFullOpenKV | real | 5000 | Whole-group common bypass full-open capacity from equipment data; not multiplied by unit count. |
| Bypass Critical Ratio xT | BypassXT | real | 0.7 | xT for expansion/choked flow; default is an estimate, prefer vendor full-open data. |
| Enable Bypass Check Action | EnableBypassCheck | check | On | Enabled check permits forward inlet-to-outlet flow only; disabled allows reverse flow under differential. |
| Bypass Cracking Differential [kPa] | BypassCrackingPressure | real | 0 | Bypass check opening differential, inlet minus outlet. Zero still requires forward-flow conditions. |
Advanced Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Use GPSA Heat Capacity Ratio | HeatCapacityRatioSource | check | EOS | GPSA ratio for this device adiabatic process only; otherwise properties. Does not change global heat capacity. Applicable about 10.2–121.3 °C, molecular mass 15–100; errors outside range, no automatic fallback. |
Parameter Guidance
Equipment and Initial Working Conditions
Set initial state, parallel unit count, mode and its dedicated setpoint, then thermal process. The network solves initial port pressures, temperatures, and flow.
| Mode | Input | Basis |
|---|---|---|
| Inlet pressure | MPa(g) | Shared suction |
| Outlet pressure | MPa(g) | Shared discharge |
| Pressure rise | MPa | Discharge minus suction |
| Standard flow | Nm³/h | Per-unit net flow |
| Shaft power | kW | Per unit |
| Pressure ratio | Dimensionless | Outlet absolute / inlet absolute |
NRN is the requested count of identical units, an integer ≥1; zero does not mean stop. Power/flow targets and limits are per unit; port flow and total shaft power are group totals. Do not multiply pressure, ratio, efficiency, or bypass Kv by count. More units can simply share the same network load.
Standard flow uses global reference conditions, default 101.325 kPa(a), 20 °C, rather than necessarily 0 °C. Calculate ratios from absolute pressures, never directly from MPag values.
Select a Compression Process
| Process | Parameters | Use |
|---|---|---|
| Isothermal | Isothermal efficiency | Constant-temperature approximation or matching power data. |
| Adiabatic | Adiabatic efficiency, heat capacity ratio source | Negligible external heat and matching efficiency data. |
| Polytropic | Polytropic efficiency | One exponent for temperature and power. |
| Empirical | K1, K2, K3, temperature exponent, coefficient reference state | Matching vendor/test data for separate power and temperature relations. |
Enter process-matched efficiencies as fractions greater than zero and no greater than one.
Control and Operating Schedule
Steady-state uses initial settings. New transients use panel initial values; past/start-time rows remain for information and do not execute. Future rows or signal control apply later. Columns are Effective Time, Operating State, Parallel Units, Mode, Setpoint:
2026-01-01 00:00:10 | On | 2 | OutletPressure | 6.0
2026-01-01 00:02:00 | Off | 2 | OutletPressure | 6.0
The first row requests a shared 6.0 MPag discharge for two units; pressures are not added. Flow/power remain per unit. Times strictly increase and each NRN is ≥1. Same-mode running changes can ramp over Setpoint Transition Time; mode switches are immediate. Normal Off cancels ramps, while standby/trip leaves schedules and trajectories advancing in absolute simulation time.
Signal modes are Setpoint Only, Run/Stop Only, or Both, with units matching mode. Held Run=1 permits operation but does not override protection or generate repeated reset requests.
Operating Constraints
Limits include maximum/minimum shaft power and standard flow, minimum suction, maximum discharge, and maximum/minimum ratio. Power/flow are per unit; pressures/ratios are shared.
Enable limits as needed. Enabled lower limits must not exceed enabled upper limits. An enabled zero upper limit means zero; disable its switch to remove it.
If requests exceed capability, a point satisfying all constraints takes priority, so pressure, flow, or power can yield. Inspect Target Reached and active boundaries. Proven infeasibility causes standby and a later topology recheck after conditions/wait; numerical failure or unknown status does not prove infeasibility.
Independent low-suction/high-discharge trips have separate trigger/release pressures. Constraints are distinct from protection. Default Run/Stop Command Reset requires Off, satisfied release/wait conditions, then a new On. Automatic Reset also requires release, wait, and operating eligibility. Early On expires without queuing/retry; multiple future On rows can be planned (e.g. early at 22 s, release at 25 s, retry at 30 s). Command reset cannot occur without effective Off/On events or a changing run source.
Bypass Settings
Choose isolation or bypass separately for normal stop, constraint standby, and trip. All three hydraulic models use a shared full-open bypass Kv for the entire group.
| Model | Setting |
|---|---|
| Expansion/choked flow | Only model using xT |
| Fixed-outlet-density differential | Uses defined outlet density in both directions |
| Pressure-squared difference | Shared critical plateau and low-drop treatment |
Bypass is full-open or isolated. Enabled check action uses inlet-minus-outlet differential and cracking criteria. Hydraulic Models
Bypass shaft power is zero. Non-isothermal bypass uses actual-direction throttling temperature. Throttling
Result Checks
Check path/state, requested/actual targets, target reached, counts, and group flow/power. Zero-head main-path flow differs from physical bypass. Valid zero-flow pressure holding or zero-head flow can retain running feedback 1; zero flow/power alone does not identify state.
Stopped bypass has zero running feedback/power but can still have port flow. Inspect trip latch, standby, and unavailability causes separately.
Professional Theory
Conservation and Operating Point
For forward main compression, are absolute Pa, . Add gauge reference separately at each side. are inlet/model discharge K; are group actual m³/s.
Mass is conserved; differing densities give differing actual flows. Standard group flow in Nm³/h uses current gas density at global standard conditions.
Target or active constraint solves jointly with the network. Fixed outlet pressure leaves flow to network conditions; fixed power includes the chosen process power relation. Below, P is group input shaft W; divide group flow/power by actual count for per-unit values.
Isothermal Process
Temperature stays at inlet. Reversible work integrates density from the equation of state along the isotherm. Isothermal efficiency converts reversible work to input shaft work.
Ideal-gas power reduces to ; real-gas calculation uses varying density.
Adiabatic Process
External heat is neglected. Efficiency modifies isentropic temperature rise and shaft power. NASA Isentropic Compression
Estimate discharge temperature with inlet ratio, then update at arithmetic midpoint pressure/temperature until consistent. Let . Power uses , with outlet Z at model discharge temperature.
Ratio normally comes from properties. Advanced Use GPSA Correlation applies only to this device adiabatic process. Let in °R, T in K, and M be relative molecular mass.
Both inlet and solution midpoint must be within 510–710 °R (about 10.2–121.3 °C) and , otherwise an error is reported.
Polytropic Process
One exponent n describes compression. Enter ; inlet determines n. BWRS uses ideal-gas ratio at inlet composition/temperature; other supported properties use actual inlet state. Density still uses the selected equation of state.
Temperature and power share the exponent; power also uses entered polytropic efficiency.
Empirical Coefficients and Reference Conditions
Use coefficient reference density for current gas at coefficient pressure/temperature. Reference flow uses m³/h. is reference K and inlet factor. Factor 1000 converts coefficient-based kW to W.
use kW/(reference m³/h), with , . Non-isothermal ; at 1, discharge equals suction temperature while power still follows the empirical relation.
Coefficient pressure uses kPa(a), temperature °C, matching data origin. Global standard conditions govern flow settings/display; changing only them at fixed gas, mass flow, and operating state does not change empirical power.
Applicability and Limits
- Capability. A target/constraint system-level model; use mapped equipment for speed, surge, and high-flow boundaries.
- Global isothermal. Port temperature is global, but process power remains; adiabatic power still uses internal model temperature for outlet properties.
- Zero flow/head. Valid pressure holding and zero-head main flow use zero power and differ from bypass. A flowing empirical compression branch can have positive power at if .
Common Inspections
- Target not reached. Check path, Target Reached, constraints, pressures, count, and protection.
- Power mismatch. Distinguish group/unit, shaft/electrical power, and actual/global-standard/coefficient-reference flow. Use absolute ratios.
- Temperature mismatch. Check global thermal mode, process, ratio, efficiency, empirical exponent, or bypass throttling.
- Invalid polytropic/GPSA data. Check and GPSA inlet/midpoint applicability.