Piston Compressor

One component represents identical parallel units at one stage. Displacement, clearance, actual speed, and compression process determine cycle-averaged flow, discharge temperature, and shaft power.

Component Appearance and Location​

Expand Compressor in the component library on the left and find "Piston Compressor".

Created with Fabric.js 5.3.0

Ports and Connections​

Normal flow runs 0→1. Bind measurements, targets, and run commands through a measurement instrument or actuator. Stopped isolation/common bypass and reverse permission follow bypass/check settings.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Per-Unit Displacement per Revolution [m³/rev]VolumetricChamberreal0.002Per-unit geometric displacement per revolution at this stage. Group sums by running count; not standard flow.
Relative Clearance VolumeRelativeClearancereal0.05Clearance/displacement ratio as a fraction, e.g. 0.05 for 5%.
Fixed Volumetric Loss LCCapacityLossConstantreal0Subtract LC directly from volumetric efficiency; retain zero without test/vendor data.
Ratio-Dependent Volumetric Loss LMCapacityLossLinearreal0Subtract LM×absolute ratio from volumetric efficiency; retain zero without data.

Compression Process

NamekeyTypeDefault / OptionsDescription
Compression Process ModelThermodynamicPathchoiceIsothermal / Adiabatic / Polytropic / EmpiricalCompression/power relation also determines piston capacity. Global isothermal fixes gas temperature while power follows process.
Isothermal EfficiencyIsothermalEfficiencyreal0.8Isothermal reversible/actual work ratio from data; existing additional mechanical losses remain active.
Adiabatic EfficiencyAdiabaticEfficiencyreal0.85Adiabatic shaft-power efficiency, also affecting non-isothermal discharge temperature. Match process/properties and vendor data. Heat capacity ratio normally uses properties; GPSA is optional in advanced settings.
Polytropic EfficiencyPolytropicEfficiencyreal0.8Polytropic shaft-power efficiency, also affecting non-isothermal discharge temperature; match equipment/process/properties.
Cycle Polytropic ExponentEmpiricalCycleIndexreal1.3Empirical cycle exponent determines work/re-expansion and default temperature; independently fit rise only with data.
Empirical Compression Efficiency SourceCompressionEfficiencySourcechoiceConstant / Pressure Ratio–Efficiency CurveConstant or pressure-ratio-dependent empirical efficiency from vendor/test data.
Empirical Efficiency CurveCurveLibraryCompressionEfficiencyNamechoice__UNSELECTED__Select a curve of the same type from the global curve library. Use the absolute discharge-to-suction pressure ratio on the horizontal axis, which must exceed 1, and an efficiency fraction in (0, 1] on the vertical axis. The solver interpolates piecewise linearly within the range. The curve must cover startup, speed changes, and operation. The solver neither extrapolates nor substitutes endpoint values.
Empirical Compression EfficiencyCompressionEfficiencyreal0.8Constant empirical compression efficiency from equipment/test data.

Initial Conditions

NamekeyTypeDefault / OptionsDescription
Initial Operating StateStatuschoiceRun / StopSteady-state and new transient initialization use panel requests/settings. Later plans/signals govern, subject to constraints/protection.
Parallel Running Units [units]NRNinteger1Positive integer count of identical parallel units; use state to stop. Flow/power are per unit and summed by count; pressure, ratio, and common bypass are not multiplied.
Operating Control ModeControlTargetchoiceFixed Speed / Fixed Outlet Pressure / Fixed Inlet Pressure / Fixed Standard Flow / Fixed Shaft Power / Fixed Pressure RatioSelect the quantity maintained through speed adjustment, subject to maps/network/constraints. Panel values establish steady-state/initial fields; loaded fields retain physical state before new control.
Speed Setpoint [rpm]SpeedSetpointreal600Requested speed subject to performance/constraints. Zero remains Run; use Stop to stop.
Outlet Pressure Setpoint [MPa(g)]DischargePressureSetpointreal4.5Outlet-connection gauge target, jointly determined with network and constraints.
Inlet Pressure Setpoint [MPa(g)]SuctionPressureSetpointreal3Inlet-connection gauge target, jointly determined with network and constraints.
Per-Unit Net Standard Flow Setpoint [Nm³/h]FlowrateSetpointreal10000Per-unit net standard delivery excluding recycle, at global references and summed by count. Zero remains Run; use Stop to stop.
Per-Unit Shaft Power Setpoint [kW]PowerSetpointreal500Per-unit input shaft power, summed by count, not electrical power. Zero remains Run; use Stop to stop.
Pressure Ratio SetpointPressureRatioSetpointreal1.5External absolute pressure ratio strictly greater than 1; not gauge ratio.

Control Source and Operating Schedule

NamekeyTypeDefault / OptionsDescription
Control SourceControlModechoiceOperating Schedule / Signal ControlTransient only. Schedules use panel initial state/future events; signals apply after physical initialization. Switching sources retains standby settings.
Signal Control ContentsSignalControlModechoiceSetpoint Only / Run/Stop Only / Run/Stop and SetpointSignals control setpoint, run/stop, or both. Run-only retains panel target. Held 0 means Stop, 1 permits Run subject to protection/eligibility.
Startup Time [s]StartupDurationreal180Positive zero-to-maximum-speed reference time. Acceleration rate is maximum speed/time for startup and adjustments; actual duration depends on speed change.
Stop Time [s]ShutdownDurationreal180Positive maximum-to-zero reference time. Normal stop/deceleration uses maximum speed/time and ends at target/zero. Protection uses separate trip action.
Operating ScheduleOperatingPlantableConfigure one row at a timeRows activate state/count/mode/target together at unique increasing future times. Past/start rows do not execute. Flow/power are per unit. Steady-state/signal mode ignores this table. Commands continue from actual speed using startup/stop rates and operating constraints.
Operating Schedule / Effective TimeOperatingPlan.timedatetime2026-01-01 00:00:00No description.
Operating Schedule / Operating StateOperatingPlan.runchoiceRun / StopNo description.
Operating Schedule / Parallel Running Units [units]OperatingPlan.nrninteger1No description.
Operating Schedule / Operating Control ModeOperatingPlan.modechoiceFixed Speed (rpm) / Fixed Outlet Pressure (MPa(g)) / Fixed Inlet Pressure (MPa(g)) / Fixed Standard Flow (Nm³/h, per unit) / Fixed Shaft Power (kW, per unit) / Fixed Ratio (dimensionless)Mode for this row; enter the target in its displayed units.
Operating Schedule / Setpoint (Units Depend on Mode)OperatingPlan.valuereal600Target according to row mode: per-unit flow/power, gauge pressure, or absolute pressure ratio.

Operating Constraints and Protection

NamekeyTypeDefault / OptionsDescription
Enable Minimum Normal SpeedEnableMinimumSpeedRPMcheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Normal Speed [rpm]MinimumSpeedRPMreal300Minimum normal actual speed; waived during finite startup/normal stop, active during normal running/adjustments.
Maximum Allowable Speed [rpm]MaximumSpeedRPMreal3000Positive equipment maximum speed, always active and the reference for all normal speed ramp rates.
Enable Minimum Inlet PressureEnableMinimumSuctionPressurecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Operating Inlet Pressure [MPa(g)]MinimumSuctionPressurereal0.1Minimum inlet gauge pressure with positive converted absolute pressure. Always active during startup/stop; independent of protection thresholds.
Enable Maximum Outlet PressureEnableMaximumOutletPressurecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating Outlet Pressure [MPa(g)]MaximumOutletPressurereal10Maximum outlet gauge pressure with positive absolute pressure. Always active; independent of high-pressure protection thresholds.
Enable Per-Unit Minimum Net Standard FlowEnableMinimumFlowratecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Minimum Net Standard Flow [Nm³/h]MinimumFlowratereal0Per-unit minimum net standard flow, excluding recycle, at global standards. Zero is zero minimum. Waived in finite startup/normal stop; does not replace anti-surge.
Enable Per-Unit Maximum Net Standard FlowEnableMaximumFlowratecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Maximum Net Standard Flow [Nm³/h]MaximumFlowratereal100000Per-unit maximum net standard flow excluding recycle. Zero is a real zero limit; disable to remove. Active during startup/stop.
Enable Per-Unit Minimum Shaft PowerEnableMinimumPowercheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Minimum Shaft Power [kW]MinimumPowerreal0Per-unit minimum shaft power, not electrical power. Zero is allowed. Waived in finite startup/normal stop; group totals use actual count.
Enable Per-Unit Maximum Shaft PowerEnableMaximumPowercheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Per-Unit Maximum Shaft Power [kW]MaximumPowerreal1000Per-unit maximum shaft power. Zero is a real zero limit; disable to remove. Always active; group totals use actual count.
Enable Minimum Operating RatioEnableMinimumPressureRatiocheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Minimum Operating RatioMinimumPressureRatioreal1Minimum absolute ratio ≥1, waived in finite startup/normal stop, active during normal operation/adjustment.
Enable Maximum Operating RatioEnableMaximumPressureRatiocheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating RatioMaximumPressureRatioreal4Maximum absolute ratio ≥1, although compression itself needs >1. Always active during startup/stop.
Enable Maximum Outlet TemperatureEnableMaximumOutletTemperaturecheckOffEnable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate.
Maximum Operating Outlet Temperature [℃]MaximumOutletTemperaturereal150Actual outlet temperature upper limit, always active. Isothermal mode checks global temperature.
Constraint Recovery Wait [s]ConstraintRecoveryDelayreal0Standby recovery needs continuous Run and feasibility for this wait; interruption restarts it. Zero still requires eligibility; excludes startup. Transient only.
Enable Low Inlet Pressure ProtectionEnableTripLowSuctionPressurecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
Low Inlet Pressure Trigger [MPa(g)]TripLowSuctionPressurereal0.05Triggers at/below actual inlet gauge pressure. Steady-state warns without timing/latching; transient continuous delay causes immediate trip without normal rundown.
Low Inlet Pressure Release [MPa(g)]TripLowSuctionPressureReleasereal0.1Release strictly above trigger, reached on its safe side. Release also needs wait, reset mode, Run, and feasibility before restart.
Low Inlet Pressure Trigger Delay [s]TripLowSuctionPressureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Enable High Outlet Pressure ProtectionEnableTripHighDischargePressurecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
High Outlet Pressure Trigger [MPa(g)]TripHighDischargePressurereal12Triggers at/above outlet gauge pressure. Steady-state warns only; transient continuous delay trips without normal rundown.
High Outlet Pressure Release [MPa(g)]TripHighDischargePressureReleasereal11Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply.
High Outlet Pressure Trigger Delay [s]TripHighDischargePressureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Enable High Outlet Temperature ProtectionEnableTripHighDischargeTemperaturecheckOffEquipment protection setting independent of operating constraints. Steady-state warns; transients trip.
High Outlet Temperature Trigger [℃]TripHighDischargeTemperaturereal180Triggers at/above actual outlet temperature. Steady-state warns only; transient delay trips without normal rundown.
High Outlet Temperature Release [℃]TripHighDischargeTemperatureReleasereal160Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply.
High Outlet Temperature Trigger Delay [s]TripHighDischargeTemperatureDelayreal0Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only.
Protection Reset ModeProtectionResetModechoiceRun/Stop Command Reset / Automatic ResetCommand reset needs Off then fresh Run after release/wait; early Run expires without queuing. Automatic reset retries after continuous release/wait. Run and feasibility still apply; without a run-command source, command reset cannot occur.
Protection Release Wait [s]TripRecoveryDelayreal0All latched causes must continuously satisfy release for this wait; interruption restarts it. Zero still needs release; reset/Run/feasibility govern restart. Transient only.

Bypass Settings

NamekeyTypeDefault / OptionsDescription
Enable Equipment BypassEnableBypasscheckOffStopped path; common bypass Kv is not multiplied by unit count.
Path After Normal StopStoppedFlowDispositionchoiceIsolation / BypassIsolation or bypass after normal stop. Flow depends on network differential, common capacity, and check settings.
Path During Constraint StandbyInfeasibleFlowDispositionchoiceIsolation / BypassIsolation or common bypass when no compression point meets constraints or during recovery wait.
Path After Protection or Power LossProtectionFlowDispositionchoiceIsolation / BypassIsolation or bypass after protection/power loss. Bypass neither releases latch nor restores drive power.
Bypass Hydraulic ModelBypassHydraulicModelchoiceExpansion/Choked Flow / Fixed-Outlet-Density Pressure Difference / Pressure-Squared DifferenceSelect bypass hydraulics from valve/pipe data. Models differ in flow at equal differential. Fixed-outlet-density uses defined outlet even in reverse.
Bypass Full-Open Kv [m³/(h·bar⁰·⁵)]BypassFullOpenKVreal10Whole-group common bypass full-open capacity from equipment data; not multiplied by unit count.
Bypass Critical Ratio xTBypassXTreal0.7xT for expansion/choked flow; default is an estimate, prefer vendor full-open data.
Enable Bypass Check ActionEnableBypassCheckcheckOnEnabled check permits forward inlet-to-outlet flow only; disabled allows reverse flow under differential.
Bypass Cracking Differential [kPa]BypassCrackingPressurereal0Bypass check opening differential, inlet minus outlet. Zero still requires forward-flow conditions.

Advanced Settings

NamekeyTypeDefault / OptionsDescription
Use GPSA Heat Capacity RatioHeatCapacityRatioSourcecheckEOSGPSA ratio for this device adiabatic process only; otherwise properties. Does not change global heat capacity. Applicable about 10.2–121.3 °C, molecular mass 15–100; errors outside range, no automatic fallback.
Custom Temperature-Rise ExponentEmpiricalTemperatureOverridecheckOffNon-isothermal empirical process only. Independently fits temperature exponent without changing capacity/work process.
Temperature-Rise ExponentEmpiricalTemperatureIndexreal1.3Custom non-isothermal empirical temperature exponent >1 from vendor/test data.

Parameter Guidance​

Capacity and Initial Conditions​

  • Displacement/clearance. Per-unit equivalent displacement is m³/rev. Clearance is fractional: 0.05 for 5%. LC subtracts directly from volumetric efficiency; LM subtracts after multiplication by absolute pressure ratio. Fixed pressure/temperature capacity factors default to 1.
  • Initial conditions. Set state, target, and positive integer count; use state to stop. Steady-state and steady-initialized transients solve actual speed from panel settings. Initialize stopped for zero-speed startup, then schedule Run.
  • Import/continuation. New initial fields retain the physical first frame but rebuild operations/protection. Continuation preserves commands, ramp progress, and protection timing.
TargetUnit/basis
Speedrpm
Inlet/outlet pressureMPa(g); converted absolute pressure must be positive
Per-unit standard volume flowNm³/h at global references
Per-unit shaft powerkW
Pressure ratioAbsolute discharge/suction, greater than 1

Flow/power targets and limits are per unit; results distinguish group totals. Do not multiply pressure, ratio, efficiency, or common bypass by count. Zero speed/flow/power targets remain Run requests subject to constraints and do not replace Stop.

Select a Compression Process​

ProcessParametersUse
IsothermalEfficiencyConstant-temperature compression and clearance re-expansion.
AdiabaticEfficiency, heat capacity ratio sourceNegligible external heat with matching data.
PolytropicEfficiency for automatic mode or custom exponentCompatible efficiency/exponent and inlet properties.
EmpiricalCycle exponent, compression efficiency, optional rise exponentSeparate fits to power and temperature data.

New compressors default to the adiabatic process. Enter efficiencies as fractions greater than zero and at most one. Empirical compression efficiency can use a constant or a pressure-ratio curve.

Enter Efficiency Curves​

For the empirical process, set Empirical Compression Efficiency Source to Pressure Ratio–Efficiency Curve. Choose Edit Local Curve to enter pairs of absolute discharge-to-suction pressure ratio and efficiency, or Reference Curve Database to select a curve by name. Pressure ratios must increase strictly and exceed one. The software interpolates efficiency linearly between points.

When the panel shows Mechanical Efficiency Curve Source, enter pairs of actual speed in rpm and mechanical efficiency. Speed must increase strictly. Enter efficiency as a fraction. This separate curve applies to the empirical process when mechanical efficiency is configured as a curve. Ensure the data cover startup, speed adjustment, and operation. Choose a curve source.

Control and Operating Schedule​

Control source, signal combination, and startup/stop times apply to transients. Setpoint Only cannot change run permission or reset a run-command latch.

Rows set effective time, state, count, mode, and value together. Use YYYY-MM-DD HH:mm:ss with strictly increasing times and one row per instant. Rows at/before start remain informational; panel defines initial state. Future rows retain original row numbers.

Startup/stop times define zero-to-maximum/maximum-to-zero rates, default 180 s each. Movement ends at target; new commands continue from actual speed and repeated targets do not restart ramps. Normal rundown continues compression until zero speed, then switches path.

Operating Constraints and Protection​

All enabled boundaries apply together. Distinguish limited operation, proven-infeasible standby, protection stop, and numerically unconfirmed status. Only during finite startup/normal stop may minimum normal speed, per-unit net flow/power, and ratio be temporarily waived. Suction minimum, upper limits, torque, and physical validity always apply. Maximum speed must be positive. Enabled zero upper flow/power means zero; disable to remove.

Low suction triggers at/below its threshold; high discharge/temperature at/above. Low release must strictly exceed trigger; high release must be strictly below. Release does not imply immediate restart. Transients time continuous violations, restarting after interruption. The trigger frame retains actual state; compression stops on the next solve. Steady-state warns without timing/latching.

Recovery settingMeaning
Constraint recovery waitRun command and continuously feasible conditions must persist through wait; interruption restarts it.
Protection release waitAll latched causes must continuously meet release conditions before reset eligibility.
Reset modeCommand reset needs Off then fresh Run; automatic reset retries after conditions are satisfied.

Both waits default to 0 s but still require eligibility and exclude startup ramp. Early Run reset expires without queuing. Restart also needs Run, available power, and feasible conditions.

Bypass Settings​

Choose isolation/common bypass separately for normal stop, standby, protection, or power loss. Hydraulics appear/apply only when bypass is enabled and selected for a path. Kv covers the whole bypass. xT applies only to expansion/choked flow; cracking differential only with check enabled. Bypass uses full-open valve relations, zero shaft power, and actual-direction throttling. Models · Temperature

Results and Saved State​

Compare unit-labeled target, actual, error, target-point speed, trajectory, and actual rpm. Unit/group loads and requested/actual counts are separate. Noncompressing target actual/error show —; port/bypass flow remains. Distinguish protection trigger frames from pending stop; advanced diagnostics expose midpoint derivatives and corrections.

Continuation preserves commands, ramps, and protection timing. New initial fields preserve physical state but rebuild memory. Gauge/standard references, properties, and equipment identity must be compatible.

Professional Theory​

Clearance Re-Expansion and Volumetric Efficiency​

High-pressure gas remains in clearance after discharge. It must expand to suction pressure before fresh intake, reducing effective intake below displacement. Larger clearance reduces fresh-gas capacity at otherwise equal conditions. Ariel Application Manual

For absolute pressures pin,poutp_{\mathrm{in}},p_{\mathrm{out}} in Pa, ratio r>1r>1, suction/model discharge temperatures Tin,TeT_{\mathrm{in}},T_e in K, clearance C and loss coefficients LC,LML_C,L_M, let Φ\Phi be re-expanded volume divided by clearance volume. Effective volumetric efficiency is

ηv=max⁡(0,  1−LC−LMr−C(Φ−1)).\eta_v=\max\bigl(0,\;1-L_C-L_M r-C(\Phi-1)\bigr).

Compute Φ\Phi below. ZinZ_{\mathrm{in}} uses suction; ZeZ_e uses discharge pressure and TeT_e. Re-expansion exponent nen_e follows the process.

ProcessΦ\PhiState/exponent
Isothermalρ(pout,Tin)/ρ(pin,Tin)\rho(p_{\mathrm{out}},T_{\mathrm{in}})/\rho(p_{\mathrm{in}},T_{\mathrm{in}})Equation-of-state densities at common suction temperature
Adiabatic/polytropic(Zin/Ze)r1/ne(Z_{\mathrm{in}}/Z_e)r^{1/n_e}Closed midpoint effective exponent / polytropic exponent
Empiricalr1/ner^{1/n_e}Cycle exponent; independent rise exponent affects temperature only

Displacement, Flow, and Shaft Power​

Let VdV_d be per-unit m³/rev, N actual rpm, NrunN_{\mathrm{run}} actual count, and fp,fTf_p,f_T capacity factors. Group suction actual flow QinQ_{\mathrm{in}} in m³/s, mass flow m˙\dot m in kg/s, and standard flow QNQ_N in Nm³/h are

Qin=NrunVdN60ηvfpfT,m˙=ρinQin,QN=3600m˙ρN.Q_{\mathrm{in}}=N_{\mathrm{run}} V_d\frac{N}{60}\eta_v f_p f_T, \qquad \dot m=\rho_{\mathrm{in}}Q_{\mathrm{in}}, \qquad Q_N=\frac{3600\dot m}{\rho_N}.

ρin,ρN\rho_{\mathrm{in}},\rho_N are suction and standard gas densities. Mass is conserved; local density converts each port actual flow. Target, constraints, and network solve speed and pressures together.

Process work w in J/kg includes process efficiency. Group shaft power in W also includes mechanical efficiency ηm\eta_m, default 1.

Pshaft=m˙ wηm.P_{\mathrm{shaft}}=\frac{\dot m\,w}{\eta_m}.

Temperature and Work for Four Processes​

Isothermal​

Te=TinT_e=T_{\mathrm{in}}. Real-gas reversible work follows the General Compressor Integral, with w=wrev/ηTw=w_{\mathrm{rev}}/\eta_T. Lower efficiency raises power at fixed pressures/speed; a power limit can then alter speed and flow.

Adiabatic​

Heat capacity ratio at arithmetic midpoint pressure/temperature closes the effective exponent against discharge temperature. Let β=1−1/ne\beta=1-1/n_e, efficiency ηA\eta_A, mean Zˉ=(Zin+Ze)/2\bar Z=(Z_{\mathrm{in}}+Z_e)/2, and specific gas constant RsR_s in J/(kg·K).

Te=Tin(1+rβ−1ηA),w=ZˉRsTinrβ−1βηA.T_e=T_{\mathrm{in}}\left(1+\frac{r^\beta-1}{\eta_A}\right), \qquad w=\bar Z R_s T_{\mathrm{in}}\frac{r^\beta-1}{\beta\eta_A}.

Default ratio comes from properties. GPSA requires both inlet/midpoint in 510–710 °R (about 10.2–121.3 °C) and molecular mass 15–100; otherwise error. GPSA

Polytropic​

BWRS inlet kink_{\mathrm{in}} is ideal-gas composition/temperature ratio; other supported models use actual suction state. Automatic β=(kin−1)/(kinηp)\beta=(k_{\mathrm{in}}-1)/(k_{\mathrm{in}}\eta_p) requires 0<β<10<\beta<1, then ne=1/(1−β)n_e=1/(1-\beta). Custom n gives β=1−1/ne\beta=1-1/n_e and equivalent ηp=(kin−1)/(kinβ)\eta_p=(k_{\mathrm{in}}-1)/(k_{\mathrm{in}}\beta), requiring 0<ηp≤10<\eta_p\le1.

Te=Tinrβ,w=pinρinrβ−1βηp.T_e=T_{\mathrm{in}}r^\beta, \qquad w=\frac{p_{\mathrm{in}}}{\rho_{\mathrm{in}}}\frac{r^\beta-1}{\beta\eta_p}.

pin/ρinp_{\mathrm{in}}/\rho_{\mathrm{in}} includes suction Z. Discharge ZeZ_e contributes to clearance capacity.

Empirical​

Cycle exponent ncn_c determines work and re-expansion, with β=1−1/nc\beta=1-1/n_c. Efficiency ηc\eta_c is constant or interpolated at actual pressure ratio.

w=pinρinrβ−1βηc,Te=Tinr(nT−1)/nT.w=\frac{p_{\mathrm{in}}}{\rho_{\mathrm{in}}}\frac{r^\beta-1}{\beta\eta_c}, \qquad T_e=T_{\mathrm{in}}r^{(n_T-1)/n_T}.

Non-isothermal rise exponent defaults to ncn_c. A custom nT>1n_T>1 affects temperature only; work and re-expansion retain ncn_c.

Applicability and Limits​

  • Single-stage cycle average. Use identical parallel units per component, separate stages and intercoolers. Pulsation, individual cylinder valves, and unloading steps are outside scope.
  • Compression. Requires discharge absolute pressure above suction. High ratio, clearance, or losses can reduce volumetric efficiency to zero, giving zero capacity.
  • Global isothermal. Port temperatures use global value; work and clearance still follow chosen process. Independent empirical rise exponent is inactive.

Common Inspections​

  • Low/zero flow. Check displacement, fractional clearance, speed/count, volumetric efficiency, absolute ratio, and constraints. Distinguish actual suction from standard flow.
  • Power/temperature mismatch. Check efficiencies, exponents, ratio, group/unit power, thermal mode, and curve range.
  • Ramp target missed. Compare target/trajectory/actual speed with speed, power, torque, and other constraints; distinguish standby and trip.
  • Flow after stop. Inspect bypass and actual path; differential/check settings determine direction.