Piston Compressor
One component represents identical parallel units at one stage. Displacement, clearance, actual speed, and compression process determine cycle-averaged flow, discharge temperature, and shaft power.
Component Appearance and Location
Expand Compressor in the component library on the left and find "Piston Compressor".
Ports and Connections
Normal flow runs 0→1. Bind measurements, targets, and run commands through a measurement instrument or actuator. Stopped isolation/common bypass and reverse permission follow bypass/check settings.
Parameter List
Equipment Specifications
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Per-Unit Displacement per Revolution [m³/rev] | VolumetricChamber | real | 0.002 | Per-unit geometric displacement per revolution at this stage. Group sums by running count; not standard flow. |
| Relative Clearance Volume | RelativeClearance | real | 0.05 | Clearance/displacement ratio as a fraction, e.g. 0.05 for 5%. |
| Fixed Volumetric Loss LC | CapacityLossConstant | real | 0 | Subtract LC directly from volumetric efficiency; retain zero without test/vendor data. |
| Ratio-Dependent Volumetric Loss LM | CapacityLossLinear | real | 0 | Subtract LM×absolute ratio from volumetric efficiency; retain zero without data. |
Compression Process
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Compression Process Model | ThermodynamicPath | choice | Isothermal / Adiabatic / Polytropic / Empirical | Compression/power relation also determines piston capacity. Global isothermal fixes gas temperature while power follows process. |
| Isothermal Efficiency | IsothermalEfficiency | real | 0.8 | Isothermal reversible/actual work ratio from data; existing additional mechanical losses remain active. |
| Adiabatic Efficiency | AdiabaticEfficiency | real | 0.85 | Adiabatic shaft-power efficiency, also affecting non-isothermal discharge temperature. Match process/properties and vendor data. Heat capacity ratio normally uses properties; GPSA is optional in advanced settings. |
| Polytropic Efficiency | PolytropicEfficiency | real | 0.8 | Polytropic shaft-power efficiency, also affecting non-isothermal discharge temperature; match equipment/process/properties. |
| Cycle Polytropic Exponent | EmpiricalCycleIndex | real | 1.3 | Empirical cycle exponent determines work/re-expansion and default temperature; independently fit rise only with data. |
| Empirical Compression Efficiency Source | CompressionEfficiencySource | choice | Constant / Pressure Ratio–Efficiency Curve | Constant or pressure-ratio-dependent empirical efficiency from vendor/test data. |
| Empirical Efficiency Curve | CurveLibraryCompressionEfficiencyName | choice | __UNSELECTED__ | Select a curve of the same type from the global curve library. Use the absolute discharge-to-suction pressure ratio on the horizontal axis, which must exceed 1, and an efficiency fraction in (0, 1] on the vertical axis. The solver interpolates piecewise linearly within the range. The curve must cover startup, speed changes, and operation. The solver neither extrapolates nor substitutes endpoint values. |
| Empirical Compression Efficiency | CompressionEfficiency | real | 0.8 | Constant empirical compression efficiency from equipment/test data. |
Initial Conditions
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Initial Operating State | Status | choice | Run / Stop | Steady-state and new transient initialization use panel requests/settings. Later plans/signals govern, subject to constraints/protection. |
| Parallel Running Units [units] | NRN | integer | 1 | Positive integer count of identical parallel units; use state to stop. Flow/power are per unit and summed by count; pressure, ratio, and common bypass are not multiplied. |
| Operating Control Mode | ControlTarget | choice | Fixed Speed / Fixed Outlet Pressure / Fixed Inlet Pressure / Fixed Standard Flow / Fixed Shaft Power / Fixed Pressure Ratio | Select the quantity maintained through speed adjustment, subject to maps/network/constraints. Panel values establish steady-state/initial fields; loaded fields retain physical state before new control. |
| Speed Setpoint [rpm] | SpeedSetpoint | real | 600 | Requested speed subject to performance/constraints. Zero remains Run; use Stop to stop. |
| Outlet Pressure Setpoint [MPa(g)] | DischargePressureSetpoint | real | 4.5 | Outlet-connection gauge target, jointly determined with network and constraints. |
| Inlet Pressure Setpoint [MPa(g)] | SuctionPressureSetpoint | real | 3 | Inlet-connection gauge target, jointly determined with network and constraints. |
| Per-Unit Net Standard Flow Setpoint [Nm³/h] | FlowrateSetpoint | real | 10000 | Per-unit net standard delivery excluding recycle, at global references and summed by count. Zero remains Run; use Stop to stop. |
| Per-Unit Shaft Power Setpoint [kW] | PowerSetpoint | real | 500 | Per-unit input shaft power, summed by count, not electrical power. Zero remains Run; use Stop to stop. |
| Pressure Ratio Setpoint | PressureRatioSetpoint | real | 1.5 | External absolute pressure ratio strictly greater than 1; not gauge ratio. |
Control Source and Operating Schedule
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Control Source | ControlMode | choice | Operating Schedule / Signal Control | Transient only. Schedules use panel initial state/future events; signals apply after physical initialization. Switching sources retains standby settings. |
| Signal Control Contents | SignalControlMode | choice | Setpoint Only / Run/Stop Only / Run/Stop and Setpoint | Signals control setpoint, run/stop, or both. Run-only retains panel target. Held 0 means Stop, 1 permits Run subject to protection/eligibility. |
| Startup Time [s] | StartupDuration | real | 180 | Positive zero-to-maximum-speed reference time. Acceleration rate is maximum speed/time for startup and adjustments; actual duration depends on speed change. |
| Stop Time [s] | ShutdownDuration | real | 180 | Positive maximum-to-zero reference time. Normal stop/deceleration uses maximum speed/time and ends at target/zero. Protection uses separate trip action. |
| Operating Schedule | OperatingPlan | table | Configure one row at a time | Rows activate state/count/mode/target together at unique increasing future times. Past/start rows do not execute. Flow/power are per unit. Steady-state/signal mode ignores this table. Commands continue from actual speed using startup/stop rates and operating constraints. |
| Operating Schedule / Effective Time | OperatingPlan.time | datetime | 2026-01-01 00:00:00 | No description. |
| Operating Schedule / Operating State | OperatingPlan.run | choice | Run / Stop | No description. |
| Operating Schedule / Parallel Running Units [units] | OperatingPlan.nrn | integer | 1 | No description. |
| Operating Schedule / Operating Control Mode | OperatingPlan.mode | choice | Fixed Speed (rpm) / Fixed Outlet Pressure (MPa(g)) / Fixed Inlet Pressure (MPa(g)) / Fixed Standard Flow (Nm³/h, per unit) / Fixed Shaft Power (kW, per unit) / Fixed Ratio (dimensionless) | Mode for this row; enter the target in its displayed units. |
| Operating Schedule / Setpoint (Units Depend on Mode) | OperatingPlan.value | real | 600 | Target according to row mode: per-unit flow/power, gauge pressure, or absolute pressure ratio. |
Operating Constraints and Protection
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Minimum Normal Speed | EnableMinimumSpeedRPM | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Normal Speed [rpm] | MinimumSpeedRPM | real | 300 | Minimum normal actual speed; waived during finite startup/normal stop, active during normal running/adjustments. |
| Maximum Allowable Speed [rpm] | MaximumSpeedRPM | real | 3000 | Positive equipment maximum speed, always active and the reference for all normal speed ramp rates. |
| Enable Minimum Inlet Pressure | EnableMinimumSuctionPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Inlet Pressure [MPa(g)] | MinimumSuctionPressure | real | 0.1 | Minimum inlet gauge pressure with positive converted absolute pressure. Always active during startup/stop; independent of protection thresholds. |
| Enable Maximum Outlet Pressure | EnableMaximumOutletPressure | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Outlet Pressure [MPa(g)] | MaximumOutletPressure | real | 10 | Maximum outlet gauge pressure with positive absolute pressure. Always active; independent of high-pressure protection thresholds. |
| Enable Per-Unit Minimum Net Standard Flow | EnableMinimumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Net Standard Flow [Nm³/h] | MinimumFlowrate | real | 0 | Per-unit minimum net standard flow, excluding recycle, at global standards. Zero is zero minimum. Waived in finite startup/normal stop; does not replace anti-surge. |
| Enable Per-Unit Maximum Net Standard Flow | EnableMaximumFlowrate | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Net Standard Flow [Nm³/h] | MaximumFlowrate | real | 100000 | Per-unit maximum net standard flow excluding recycle. Zero is a real zero limit; disable to remove. Active during startup/stop. |
| Enable Per-Unit Minimum Shaft Power | EnableMinimumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Minimum Shaft Power [kW] | MinimumPower | real | 0 | Per-unit minimum shaft power, not electrical power. Zero is allowed. Waived in finite startup/normal stop; group totals use actual count. |
| Enable Per-Unit Maximum Shaft Power | EnableMaximumPower | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Per-Unit Maximum Shaft Power [kW] | MaximumPower | real | 1000 | Per-unit maximum shaft power. Zero is a real zero limit; disable to remove. Always active; group totals use actual count. |
| Enable Minimum Operating Ratio | EnableMinimumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Minimum Operating Ratio | MinimumPressureRatio | real | 1 | Minimum absolute ratio ≥1, waived in finite startup/normal stop, active during normal operation/adjustment. |
| Enable Maximum Operating Ratio | EnableMaximumPressureRatio | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Ratio | MaximumPressureRatio | real | 4 | Maximum absolute ratio ≥1, although compression itself needs >1. Always active during startup/stop. |
| Enable Maximum Outlet Temperature | EnableMaximumOutletTemperature | check | Off | Enable to show/check the limit. Disabled standby values are retained but unused. Constraints and protection are separate. |
| Maximum Operating Outlet Temperature [℃] | MaximumOutletTemperature | real | 150 | Actual outlet temperature upper limit, always active. Isothermal mode checks global temperature. |
| Constraint Recovery Wait [s] | ConstraintRecoveryDelay | real | 0 | Standby recovery needs continuous Run and feasibility for this wait; interruption restarts it. Zero still requires eligibility; excludes startup. Transient only. |
| Enable Low Inlet Pressure Protection | EnableTripLowSuctionPressure | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| Low Inlet Pressure Trigger [MPa(g)] | TripLowSuctionPressure | real | 0.05 | Triggers at/below actual inlet gauge pressure. Steady-state warns without timing/latching; transient continuous delay causes immediate trip without normal rundown. |
| Low Inlet Pressure Release [MPa(g)] | TripLowSuctionPressureRelease | real | 0.1 | Release strictly above trigger, reached on its safe side. Release also needs wait, reset mode, Run, and feasibility before restart. |
| Low Inlet Pressure Trigger Delay [s] | TripLowSuctionPressureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Enable High Outlet Pressure Protection | EnableTripHighDischargePressure | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| High Outlet Pressure Trigger [MPa(g)] | TripHighDischargePressure | real | 12 | Triggers at/above outlet gauge pressure. Steady-state warns only; transient continuous delay trips without normal rundown. |
| High Outlet Pressure Release [MPa(g)] | TripHighDischargePressureRelease | real | 11 | Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply. |
| High Outlet Pressure Trigger Delay [s] | TripHighDischargePressureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Enable High Outlet Temperature Protection | EnableTripHighDischargeTemperature | check | Off | Equipment protection setting independent of operating constraints. Steady-state warns; transients trip. |
| High Outlet Temperature Trigger [℃] | TripHighDischargeTemperature | real | 180 | Triggers at/above actual outlet temperature. Steady-state warns only; transient delay trips without normal rundown. |
| High Outlet Temperature Release [℃] | TripHighDischargeTemperatureRelease | real | 160 | Release strictly below trigger, reached on its safe side; wait/reset/Run/feasibility still apply. |
| High Outlet Temperature Trigger Delay [s] | TripHighDischargeTemperatureDelay | real | 0 | Continuous violation duration before trip; interruption restarts timing. Zero trips at a confirmed violating state without added wait. Transient only. |
| Protection Reset Mode | ProtectionResetMode | choice | Run/Stop Command Reset / Automatic Reset | Command reset needs Off then fresh Run after release/wait; early Run expires without queuing. Automatic reset retries after continuous release/wait. Run and feasibility still apply; without a run-command source, command reset cannot occur. |
| Protection Release Wait [s] | TripRecoveryDelay | real | 0 | All latched causes must continuously satisfy release for this wait; interruption restarts it. Zero still needs release; reset/Run/feasibility govern restart. Transient only. |
Bypass Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Enable Equipment Bypass | EnableBypass | check | Off | Stopped path; common bypass Kv is not multiplied by unit count. |
| Path After Normal Stop | StoppedFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after normal stop. Flow depends on network differential, common capacity, and check settings. |
| Path During Constraint Standby | InfeasibleFlowDisposition | choice | Isolation / Bypass | Isolation or common bypass when no compression point meets constraints or during recovery wait. |
| Path After Protection or Power Loss | ProtectionFlowDisposition | choice | Isolation / Bypass | Isolation or bypass after protection/power loss. Bypass neither releases latch nor restores drive power. |
| Bypass Hydraulic Model | BypassHydraulicModel | choice | Expansion/Choked Flow / Fixed-Outlet-Density Pressure Difference / Pressure-Squared Difference | Select bypass hydraulics from valve/pipe data. Models differ in flow at equal differential. Fixed-outlet-density uses defined outlet even in reverse. |
| Bypass Full-Open Kv [m³/(h·bar⁰·⁵)] | BypassFullOpenKV | real | 10 | Whole-group common bypass full-open capacity from equipment data; not multiplied by unit count. |
| Bypass Critical Ratio xT | BypassXT | real | 0.7 | xT for expansion/choked flow; default is an estimate, prefer vendor full-open data. |
| Enable Bypass Check Action | EnableBypassCheck | check | On | Enabled check permits forward inlet-to-outlet flow only; disabled allows reverse flow under differential. |
| Bypass Cracking Differential [kPa] | BypassCrackingPressure | real | 0 | Bypass check opening differential, inlet minus outlet. Zero still requires forward-flow conditions. |
Advanced Settings
| Name | key | Type | Default / Options | Description |
|---|---|---|---|---|
| Use GPSA Heat Capacity Ratio | HeatCapacityRatioSource | check | EOS | GPSA ratio for this device adiabatic process only; otherwise properties. Does not change global heat capacity. Applicable about 10.2–121.3 °C, molecular mass 15–100; errors outside range, no automatic fallback. |
| Custom Temperature-Rise Exponent | EmpiricalTemperatureOverride | check | Off | Non-isothermal empirical process only. Independently fits temperature exponent without changing capacity/work process. |
| Temperature-Rise Exponent | EmpiricalTemperatureIndex | real | 1.3 | Custom non-isothermal empirical temperature exponent >1 from vendor/test data. |
Parameter Guidance
Capacity and Initial Conditions
- Displacement/clearance. Per-unit equivalent displacement is m³/rev. Clearance is fractional: 0.05 for 5%. LC subtracts directly from volumetric efficiency; LM subtracts after multiplication by absolute pressure ratio. Fixed pressure/temperature capacity factors default to 1.
- Initial conditions. Set state, target, and positive integer count; use state to stop. Steady-state and steady-initialized transients solve actual speed from panel settings. Initialize stopped for zero-speed startup, then schedule Run.
- Import/continuation. New initial fields retain the physical first frame but rebuild operations/protection. Continuation preserves commands, ramp progress, and protection timing.
| Target | Unit/basis |
|---|---|
| Speed | rpm |
| Inlet/outlet pressure | MPa(g); converted absolute pressure must be positive |
| Per-unit standard volume flow | Nm³/h at global references |
| Per-unit shaft power | kW |
| Pressure ratio | Absolute discharge/suction, greater than 1 |
Flow/power targets and limits are per unit; results distinguish group totals. Do not multiply pressure, ratio, efficiency, or common bypass by count. Zero speed/flow/power targets remain Run requests subject to constraints and do not replace Stop.
Select a Compression Process
| Process | Parameters | Use |
|---|---|---|
| Isothermal | Efficiency | Constant-temperature compression and clearance re-expansion. |
| Adiabatic | Efficiency, heat capacity ratio source | Negligible external heat with matching data. |
| Polytropic | Efficiency for automatic mode or custom exponent | Compatible efficiency/exponent and inlet properties. |
| Empirical | Cycle exponent, compression efficiency, optional rise exponent | Separate fits to power and temperature data. |
New compressors default to the adiabatic process. Enter efficiencies as fractions greater than zero and at most one. Empirical compression efficiency can use a constant or a pressure-ratio curve.
Enter Efficiency Curves
For the empirical process, set Empirical Compression Efficiency Source to Pressure Ratio–Efficiency Curve. Choose Edit Local Curve to enter pairs of absolute discharge-to-suction pressure ratio and efficiency, or Reference Curve Database to select a curve by name. Pressure ratios must increase strictly and exceed one. The software interpolates efficiency linearly between points.
When the panel shows Mechanical Efficiency Curve Source, enter pairs of actual speed in rpm and mechanical efficiency. Speed must increase strictly. Enter efficiency as a fraction. This separate curve applies to the empirical process when mechanical efficiency is configured as a curve. Ensure the data cover startup, speed adjustment, and operation. Choose a curve source.
Control and Operating Schedule
Control source, signal combination, and startup/stop times apply to transients. Setpoint Only cannot change run permission or reset a run-command latch.
Rows set effective time, state, count, mode, and value together. Use YYYY-MM-DD HH:mm:ss with strictly increasing times and one row per instant. Rows at/before start remain informational; panel defines initial state. Future rows retain original row numbers.
Startup/stop times define zero-to-maximum/maximum-to-zero rates, default 180 s each. Movement ends at target; new commands continue from actual speed and repeated targets do not restart ramps. Normal rundown continues compression until zero speed, then switches path.
Operating Constraints and Protection
All enabled boundaries apply together. Distinguish limited operation, proven-infeasible standby, protection stop, and numerically unconfirmed status. Only during finite startup/normal stop may minimum normal speed, per-unit net flow/power, and ratio be temporarily waived. Suction minimum, upper limits, torque, and physical validity always apply. Maximum speed must be positive. Enabled zero upper flow/power means zero; disable to remove.
Low suction triggers at/below its threshold; high discharge/temperature at/above. Low release must strictly exceed trigger; high release must be strictly below. Release does not imply immediate restart. Transients time continuous violations, restarting after interruption. The trigger frame retains actual state; compression stops on the next solve. Steady-state warns without timing/latching.
| Recovery setting | Meaning |
|---|---|
| Constraint recovery wait | Run command and continuously feasible conditions must persist through wait; interruption restarts it. |
| Protection release wait | All latched causes must continuously meet release conditions before reset eligibility. |
| Reset mode | Command reset needs Off then fresh Run; automatic reset retries after conditions are satisfied. |
Both waits default to 0 s but still require eligibility and exclude startup ramp. Early Run reset expires without queuing. Restart also needs Run, available power, and feasible conditions.
Bypass Settings
Choose isolation/common bypass separately for normal stop, standby, protection, or power loss. Hydraulics appear/apply only when bypass is enabled and selected for a path. Kv covers the whole bypass. xT applies only to expansion/choked flow; cracking differential only with check enabled. Bypass uses full-open valve relations, zero shaft power, and actual-direction throttling. Models · Temperature
Results and Saved State
Compare unit-labeled target, actual, error, target-point speed, trajectory, and actual rpm. Unit/group loads and requested/actual counts are separate. Noncompressing target actual/error show —; port/bypass flow remains. Distinguish protection trigger frames from pending stop; advanced diagnostics expose midpoint derivatives and corrections.
Continuation preserves commands, ramps, and protection timing. New initial fields preserve physical state but rebuild memory. Gauge/standard references, properties, and equipment identity must be compatible.
Professional Theory
Clearance Re-Expansion and Volumetric Efficiency
High-pressure gas remains in clearance after discharge. It must expand to suction pressure before fresh intake, reducing effective intake below displacement. Larger clearance reduces fresh-gas capacity at otherwise equal conditions. Ariel Application Manual
For absolute pressures in Pa, ratio , suction/model discharge temperatures in K, clearance C and loss coefficients , let be re-expanded volume divided by clearance volume. Effective volumetric efficiency is
Compute below. uses suction; uses discharge pressure and . Re-expansion exponent follows the process.
| Process | State/exponent | |
|---|---|---|
| Isothermal | Equation-of-state densities at common suction temperature | |
| Adiabatic/polytropic | Closed midpoint effective exponent / polytropic exponent | |
| Empirical | Cycle exponent; independent rise exponent affects temperature only |
Displacement, Flow, and Shaft Power
Let be per-unit m³/rev, N actual rpm, actual count, and capacity factors. Group suction actual flow in m³/s, mass flow in kg/s, and standard flow in Nm³/h are
are suction and standard gas densities. Mass is conserved; local density converts each port actual flow. Target, constraints, and network solve speed and pressures together.
Process work w in J/kg includes process efficiency. Group shaft power in W also includes mechanical efficiency , default 1.
Temperature and Work for Four Processes
Isothermal
. Real-gas reversible work follows the General Compressor Integral, with . Lower efficiency raises power at fixed pressures/speed; a power limit can then alter speed and flow.
Adiabatic
Heat capacity ratio at arithmetic midpoint pressure/temperature closes the effective exponent against discharge temperature. Let , efficiency , mean , and specific gas constant in J/(kg·K).
Default ratio comes from properties. GPSA requires both inlet/midpoint in 510–710 °R (about 10.2–121.3 °C) and molecular mass 15–100; otherwise error. GPSA
Polytropic
BWRS inlet is ideal-gas composition/temperature ratio; other supported models use actual suction state. Automatic requires , then . Custom n gives and equivalent , requiring .
includes suction Z. Discharge contributes to clearance capacity.
Empirical
Cycle exponent determines work and re-expansion, with . Efficiency is constant or interpolated at actual pressure ratio.
Non-isothermal rise exponent defaults to . A custom affects temperature only; work and re-expansion retain .
Applicability and Limits
- Single-stage cycle average. Use identical parallel units per component, separate stages and intercoolers. Pulsation, individual cylinder valves, and unloading steps are outside scope.
- Compression. Requires discharge absolute pressure above suction. High ratio, clearance, or losses can reduce volumetric efficiency to zero, giving zero capacity.
- Global isothermal. Port temperatures use global value; work and clearance still follow chosen process. Independent empirical rise exponent is inactive.
Common Inspections
- Low/zero flow. Check displacement, fractional clearance, speed/count, volumetric efficiency, absolute ratio, and constraints. Distinguish actual suction from standard flow.
- Power/temperature mismatch. Check efficiencies, exponents, ratio, group/unit power, thermal mode, and curve range.
- Ramp target missed. Compare target/trajectory/actual speed with speed, power, torque, and other constraints; distinguish standby and trip.
- Flow after stop. Inspect bypass and actual path; differential/check settings determine direction.