Multiport Gas Tank

Multiple pipelines share one gas space. Actual port flows determine inventory, pressure, temperature, and composition for source collection and parallel supply.

Component Appearance and Location​

Find Multiport Gas Tank under Tanks.

Created with Fabric.js 5.3.0

Ports and Connections​

Port KeyTypeDirectionInterface NameDisplay Conditions
in1FLUIDinputImport 1The import quantity is not less than 1
in2FLUIDinputImport 2Import quantity is not less than 2
in3FLUIDinputImport 3The import quantity is not less than 3
in4FLUIDinputImport 4Import quantity is not less than 4
in5FLUIDinputImport 5Import quantity is 5
out1FLUIDoutputExit 1The export quantity is not less than 1
out2FLUIDoutputExit 2The export quantity is not less than 2
out3FLUIDoutputExit 3The export quantity is not less than 3
out4FLUIDoutputExit 4The export quantity is not less than 4
out5FLUIDoutputExit 5The export quantity is 5

Positive inlet flow enters; positive outlet flow leaves; negative reverses each convention. Unconnected configured ports are sealed. Use a Measurement Instrument for tank/port measurements and Port Change Schedule for actions.

Parameter List​

Equipment Specifications

NamekeyTypeDefault / OptionsDescription
Tank Volume [m³]TankVolumereal15Effective geometric gas volume for initial inventory and transient charging/withdrawal.
Connection Elevation [m]PortElevationreal0Shared connection elevation on the network datum, matching connected pipes. Individual port elevations are not modeled.
Low-Pressure Protection Limit [MPa(g)]MinPressurereal0At or below this transient pressure, all ports latch closed. A later Open event after recovery releases only selected ports; violations relatch. This is protection, not a pressure target. Equal limits leave no open interval.
High-Pressure Protection Limit [MPa(g)]MaxPressurereal150At or above this transient pressure, all ports latch closed. A later Open event after recovery restores only selected ports; violations relatch. It does not clamp tank pressure.

Thermal Calculation

NamekeyTypeDefault / OptionsDescription
Heat Transfer Area [m²]SurfaceAreareal35Effective area on the coefficient basis; tank-wall thermal storage is not modeled.
Overall Heat Transfer Coefficient ModeHeatTransferCoefficientInputModechoiceFixed Value / Time CurveFixed or time-dependent overall coefficient for non-isothermal transients.
Tank Overall Heat Transfer Coefficient [W/(m²·K)]HeatTransferRatereal0Coefficient based on tank area. Zero removes environmental exchange but flow can still change temperature. Fixed mode retains area/environment settings.
Overall Coefficient CurveCurveLibraryHeatTransferCoefficientNamechoice__UNSELECTED__Select a time series for the overall heat transfer coefficient. The coefficient applies to this tank's heat transfer area, and the series must cover the transient simulation period.
Ambient Temperature ModeAmbientTemperatureInputModechoiceFixed Value / Time CurveChoose fixed ambient temperature or a time curve.
Ambient Temperature [℃]AmbientTemperaturereal25Ambient tank temperature for non-isothermal transient heat transfer.
Ambient Temperature CurveCurveLibraryTemperatureNamechoice__UNSELECTED__Select a time series for the ambient temperature outside the tank. The series must cover the transient simulation period.

Gas and Initial Conditions

NamekeyTypeDefault / OptionsDescription
Initial Tank GasInitialCompositionalFluidchoice—Initial tank gas, subsequently updated by port balances and inventory mixing.
Initial Tank GasInitialSimpleFluidchoice—Initial tank gas, subsequently updated by port balances and inventory mixing.
Initial Tank Pressure [MPa(g)]InitialPressurereal10Initial gauge pressure: open-port boundary in steady-state, initial inventory in transients. Steady-state does not evolve inventory.
Initial Tank Temperature [℃]InitialTemperaturereal25Initial non-isothermal tank temperature; steady-state uses it for boundaries, transients evolve it with flow/heat. Isothermal uses global temperature.

Inlet and Outlet Configuration

NamekeyTypeDefault / OptionsDescription
Inlet CountInletCountchoice1 / 2 / 3 / 4 / 5Configured inlet count, allowing unconnected ports. Before reducing, remove affected wiring, active events, and measurements.
Outlet CountOutletCountchoice1 / 2 / 3 / 4 / 5Configured outlet count, allowing unconnected ports. Before reducing, remove affected wiring, active events, and measurements.
Initial Inlet 1 StateInlet1StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Inlet 2 StateInlet2StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Inlet 3 StateInlet3StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Inlet 4 StateInlet4StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Inlet 5 StateInlet5StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Outlet 1 StateOutlet1StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Outlet 2 StateOutlet2StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Outlet 3 StateOutlet3StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Outlet 4 StateOutlet4StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.
Initial Outlet 5 StateOutlet5StatuschoiceOpen / ClosedInitial port state. Closing affects only that port; other open ports still flow. Protection closes all, and later Open restores selected ports only.

Transient Events

NamekeyTypeDefault / OptionsDescription
Port Change ScheduleEventstableConfigure one row at a timeFuture actions execute once; start/past events remain informational. Open restores selected ports only; violations keep all closed.
Port Change Schedule / TimeEvents.timedatetime2026-01-01 00:00:00Event effective time.
Port Change Schedule / Port TargetEvents.TargetPortchoiceallPort or group receiving the action.
Port Change Schedule / ActionEvents.ActionchoiceOpen / ClosedAction applied to the selected ports.

Parameter Guidance​

  • Counts/states. Select 1–5 inlets and 1–5 outlets and set states individually. Remove wiring, actions, and references before hiding ports.
  • Volume/elevation/gas. All ports share geometric gas volume and connection elevation. Select matching initial gas and gauge pressure; thermal mode determines panel/global temperature.
  • Protection. Normal transient pressure must be strictly between low/high MPa(g) limits; either closes every port.
  • Environmental heat transfer. Applies during non-isothermal transients. Use the same area basis for the heat transfer area and overall coefficient. Choose a fixed value or time curve separately for coefficient and ambient temperature. Curves must cover the calculation interval.

Enter Environmental Curves​

For each input configured as a Time Curve, choose Edit Local Curve to enter time and value pairs on the tank or Reference Curve Database to select a named curve of the same type. Use W/(m²·K) for overall heat transfer coefficient and °C for ambient temperature. The curves define environmental conditions for the entire tank and apply to all ports. Choose a curve source.

Port Change Schedule​

Rows specify time, port/group, and open/close. Groups include all inlets, all outlets, or all ports. Initial states use panel; only later events execute. Order future times; multiple rows at one time are allowed.

Group commands expand to configured ports before simultaneous execution. Duplicate identical actions execute once; conflicting open/close commands on one port, such as All Inlets open and Inlet 2 closed, must be corrected.

Modeling Steps​

  1. Set counts, connect branches, and check numbering.
  2. Set volume, elevation, limits, gas, pressure, and states.
  3. Set non-isothermal temperature and transient heat.
  4. Schedule individual/group actions and check conflicts.
  5. Inspect per-port direction/state, net mass flow, inventory, and protection.

View Results​

  • Ports. State, MPa(g), °C, standard Nm³/h, and actual m³/h. Unconnected shows zero flow and tank-side pressure/temperature.
  • Totals. Actual directions determine total inflow/outflow/net kg/s. Positive transient net adds inventory. Standard inventory is Nm³.
  • Thermal/protection. Compare whole-tank protection and port states; temperature and environmental heat kW explain isolated changes.

Saved State​

Continuation preserves actual states, protection, and event progress. New initial-field loading retains physical state/inventory but rebuilds operations from target start and panel states and rechecks protection.

Professional Theory​

Multiport Mass Balance​

All ports share fixed volume and uniform state. Current properties convert inventory and standard volume; temperature/composition also affect pressure. Inventory

For inlet/outlet sets I,O\mathcal I,\mathcal O, signed actual flows qiq_i in m³/s and local densities ρi\rho_i in kg/m³, transient mass changes as

dmdt=∑i∈Iρiqi−∑j∈Oρjqj.\frac{\mathrm{d}m}{\mathrm{d}t} =\sum_{i\in\mathcal I}\rho_i q_i-\sum_{j\in\mathcal O}\rho_j q_j.

This is total actual inflow minus outflow; reversed outlets count inward. Convert each flow with its actual density before summing. Two-Port Balance

Incoming Enthalpy and Mixing​

Sum actual incoming enthalpy flows; all outgoing gas uses current tank temperature/composition. Environmental heat continues when all ports close. Energy

Convert incoming mass flows using each molar mass, then accumulate by source gas. For inward branches with molar flows N˙i\dot N_i in kmol/s and mole-fraction vectors yi\boldsymbol{y}_i, combined inflow composition is

ymix,in=∑iN˙iyi∑iN˙i.\boldsymbol{y}_{\mathrm{mix,in}} =\frac{\sum_i \dot N_i\boldsymbol{y}_i}{\sum_i \dot N_i}.

Combine incoming gas with existing inventory for current composition. All outflows share it. Equal mass inflow/outflow can still change delivered composition. Molar Mixing

Shared Pressure and Group Recovery​

Steady-state open ports impose initial pressure with independently solved flows and initial inventory. Transient connected open ports share current pressure; closed ports have zero flow. Branch flows depend on network conditions; connection losses/elevation differences are outside scope.

Either limit latches all ports during transient initialization/runtime. Initial violations keep specified pressure in a closed field. Independent steady-state only warns and follows panel states.

After pressure returns strictly inside limits, an Open action releases the latch only for its selected port/group. Other protected ports remain closed. If pressure still violates limits, all relatch.

Applicability and Limits​

  • Shared storage. Use for source collection and branch supply; transient mode tracks inventory/pressure/composition.
  • Lumped model. Shared state/elevation excludes local mixing, stratification, wall storage, and connection losses.
  • Directions. Both inlet/outlet ports can reverse; add Check Valves where needed.

Common Inspections​

  • Unexpected inventory direction. Confirm transients, signs, states, densities, and net mass.
  • Validation after count changes. Remove hidden-port wiring/actions/references.
  • Simultaneous conflicts. Expand groups and find opposing actions per port.
  • Branches remain closed after recovery. Check pressure and inclusion in the Open action.
  • Stable inventory but changing composition. Check incoming compositions/directions and molar inventory.