Load

The sink is used to represent downstream users, distribution branches or export systems, and is the boundary where gas leaves the pipeline network. The sink point can be given a given air flow rate or a given downstream pressure, and the pipeline network will calculate the pressure or actual external flow rate corresponding to the boundary.

Component Appearance and Location​

Expand Border in the component library on the left and find "Meeting Point".

Created with Fabric.js 5.3.0

Ports and Connections​

Port KeyTypeDirectionInterface NameDisplay Conditions
0FLUIDinputfluid inletalways show

Connect the fluid inlet to a consumer, offtake, or export branch. Positive flow withdraws gas; negative flow returns gas to the network. A Measurement Instrument reads pressure and flow. Set boundaries in the panel and Boundary Change Schedule.

Parameter List​

Boundary Conditions

NamekeyTypeDefault / OptionsDescription
Boundary TypeBoundTypechoicePressure / FlowPressure boundary imposes pressure and solves flow; flow boundary imposes standard flow and solves pressure. Steady-state uses initial settings without executing saved schedules.
Boundary Pressure [MPa(g)]BoundPressurereal2Gauge pressure target for pressure mode; flow is solved. Converted absolute pressure must be positive.
Standard Volume Flow [Nm³/h]BoundFlowratereal100Volume flow at global standard P/T. Positive withdraws, negative returns gas. Load composition/temperature come from upstream; reversal needs prior valid incoming state. Use a source for initial supply.

Transient Events

NamekeyTypeDefault / OptionsDescription
Boundary Transition Time [s]RampTimereal0Same-type boundary ramp duration. Zero is immediate; new events restart from reached value. Switching pressure/flow types is immediate.
Boundary Change ScheduleEventstableConfigure one row at a timeNew boundary conditions from each unique increasing effective time. Later events can interrupt ramps; steady-state retains but does not execute plans.
Boundary Change Schedule / Effective TimeEvents.timedatetime2026-01-01 00:00:00Boundary activation datetime, strictly ordered and unique.
Boundary Change Schedule / Boundary TypeEvents.boundTypechoicePressure / FlowPressure or standard volume flow for this row; recheck units/value after switching.
Boundary Change Schedule / Setpoint [MPa(g) / Nm³/h]Events.condValuereal100Gauge pressure for pressure rows, standard flow at global P/T for flow rows. Positive withdraws, negative reverses. Recheck values/units after type changes.

Parameter Guidance​

  • Boundary Type. Enter Boundary Pressure in MPa(g) for pressure mode or Standard Volume Flow in Nm³/h for flow mode. Normal demand/export uses positive flow. Conversions use global gauge reference, standard pressure and temperature, and port gas. Reference Conditions

Boundary Change Schedule​

Steady-state uses initial panel settings. For transient simulation, enter effective time, boundary type, and value in strictly increasing, nonduplicate rows. Pressure rows use gauge pressure; flow rows use standard volume flow.

Boundary Transition Time (s) is shared by all rows. Same-type events ramp linearly from the reached value to the new target. A new event interrupts and restarts the ramp. Zero duration or switching pressure/flow type applies the target immediately. If simulation starts during a ramp, it continues from that point. Source Transitions

Modeling Steps​

  1. Add a load and connect it to the terminal or offtake branch.
  2. Use pressure for known receiving pressure or flow for known demand/export plans; follow the units.
  3. Set transient schedule and transition time if needed.
  4. Check connected-network pressure constraints and boundaries, then compare results with active settings.

View Results​

  • Pressure mode. Compare pressure to the active setpoint and use actual standard flow and sign for export and direction.
  • Flow mode. Compare standard flow to simultaneous demand and check terminal pressure. Actual volume flow varies with pressure, temperature, and gas.
  • Gas and temperature. Interpret port conditions with direction; normal withdrawal reflects network inflow.
  • Transients. Compare event times and ramps; assess supply response using pressure, actual flow, and logs.

Professional Theory​

Pressure and Flow Boundaries​

Pressure mode converts gauge to absolute pressure and applies it to the connected node. Network supply, resistance, and equipment determine flow, including possible reversal. Pressure Conversion

Flow mode converts standard flow to mass flow using port gas standard density; network solving determines pressure. Flow into the load is positive. Mass flow varies with standard density; actual volume flow also depends on operating density. Flow Conversion

Demand and Actual Withdrawal​

In flow mode, the current panel or schedule value is demand. Actual standard flow meets it when supply is sufficient and the boundary remains valid. During transients, insufficient linepack or tank inventory, or local low-pressure protection, can limit actual withdrawal, down to zero, while retaining the requested demand.

Check minimum terminal operating pressure separately: meeting flow demand does not ensure adequate pressure.

Temperature, Gas, and Reverse Flow​

Normal withdrawal inherits gas and temperature from the network. Reverse flow uses previously received and saved gas and temperature. Reversal before receiving gas causes an error. Isothermal mode uses global temperature. Zero flow transports no gas.

Applicability and Limits​

  • Demand or receiving pressure. Use flow for known demand and check pressure; use pressure for known receiving pressure and check flow.
  • External supply. Use a Source for initial supply or independent temperature/composition.
  • One-way withdrawal. Add a Check Valve where needed.
  • Pressure constraints. Each separate steady-state network must determine absolute pressure; fixed pressures at one node must agree.

Common Inspections​

  • Withdrawal below plan. Confirm flow mode and simultaneous standard values; check supply, inventory, and limiting/low-pressure logs.
  • Pressure mismatch. Check pressure mode, units, gauge reference, and active event.
  • Negative flow or initial reversal error. Check signs, surrounding pressures, and whether a source is needed.
  • Unexpected transient timing. Check type, order, row units, transition time, and start.
  • Undetermined or conflicting pressure. Check connectivity and fixed-pressure consistency.