GasLib-134 Standard Pipeline Network Medium Load Compression Operation

Based on GasLib-134 Q50 medium demand, this steady network has 134 nodes, 3 sources, 45 loads, a compressor, and a regulator. Check source allocation, load pressures, active boosting, regulation, and node conservation alongside equipment state.

Study Overview​

ItemConfiguration
ScenarioQ50, 2012-08-28
Network134 nodes, 3 sources, 45 loads, 86 pipes, 1 compressor, 1 regulator
AnalysisSteady-state, isothermal
Supply/demand401549.35 Nm³/h each; 2 nonzero sources, 33 nonzero loads
Devicescs active 0.15 MPa rise; controlValve_br65 outlet pressure control
ChecksAllocation, pressure/flow, power, states, conservation, pressure closure
ScopeLarge-network validation and interpretation

Working Conditions Background and Pipe Network Structure​

Working Condition Background​

Large networks combine sources, offtakes, loops, and trees. Pressure slack supply balances specified loads; compression and regulation maintain local conditions. Success also requires boundary, state, conservation, pressure closure, and convergence checks.

This example belongs to the GasLib standard network benchmark that has been adapted to the project. It is used to verify large-scale network modeling and result interpretation methods. It does not represent the compression station selection, pipeline transmission plan or scheduling plan of a specific project.

Pipe Network Structure​

GasLib-134 Network Topology Overview
GasLib-134 Network Topology Overview

Figure: GasLib-134 full network topology overview. This diagram is used to identify the overall shape of the network and the connection relationships between various regions.

Long pipelines connect distributed regions; cs lies on the main path and controlValve_br65 at a downstream zone entry. All boundaries, resistance, and settings determine flow.

Due to the large number of nodes in the entire network, a single overview diagram cannot ensure that the overall structure and component labels are clear at the same time. The following is a partial structure diagram based on the upper left, upper right, middle and lower areas. A small number of overlapping connections are retained between each diagram to facilitate correspondence with the entire network overview.

Upper Left Area

GasLib-134 upper left area pipe network
GasLib-134 upper left area pipe network

Upper Right Area

GasLib-134 Upper right area pipe network (rotated 90° to the right)
GasLib-134 Upper right area pipe network (rotated 90° to the right)

Picture: Upper right regional pipe network. The original screenshot is rotated 90° clockwise and placed.

Central Region

GasLib-134 Central Regional Pipeline Network
GasLib-134 Central Regional Pipeline Network

Lower Area

GasLib-134 lower area pipe network
GasLib-134 lower area pipe network

Figure: GasLib-134 zoned pipe network structure. The local map is used to identify gas sources, loads, pipelines and equipment labels; node connection relationships are still indexed by the full network overview.

Pipeline Representation and Adaptation Range​

TypeQuantityModeling ApproachDescription
Long physical pipeline78 paragraphsLongPipeFDM long pipe hydraulic solution is used; the length of a single section is 3.598~73.190 km
Shorter physical pipeline8 paragraphsPipeSingle section length 0.651~2.915 km
GasLib shortPipe45 paragraphs1 m, DN1000 PipeIt is used to retain the standard network connection relationship and is not interpreted as an actual pipeline segment.

The total length of 86 physical pipeline sections is approximately 1447.02 km, of which 78 long pipe sections have a total length of approximately 1433.60 km. The diameter range of long tube is 254~914.4 mm. The 45-segment connecting adapter pipe is not counted in the physical pipe quantity and the total physical pipe length.

Boundary Conditions and Simulation Setup​

Air Source and Load Boundaries​

BoundaryTypeValueMeaning
node_1Flow source82197.50 Nm³/h; 5.40317 MPag solvedFixed supply
node_20Pressure source5.277675 MPag; 319351.85 Nm³/h solvedSlack supply
node_80Zero-flow source0; 3.98599 MPag solvedInactive supply
45 loadsFlowTotal 401549.35 Nm³/h33 nonzero, 12 zero

node_1 and node_20 bear about 20.47% and 79.53% of the total air supply volume respectively. The flow rate of the pressure relaxation gas source is not a predetermined result, but a balanced quantity obtained by the network after all loads, pipeline pressure drops and equipment settings are met.

The load is mainly concentrated on several nodes. The following table lists the seven loads with the largest traffic, which together account for approximately 88.17% of the entire network load.

LoadNm³/hMPag
node_ld4282197.503.12679
node_ld3256043.753.96764
node_ld2556043.754.07779
node_ld2746718.074.04567
node_ld1242970.615.10336
node_ld2437362.504.07779
node_ld3132692.193.96764

Compressor and Regulator Settings​

DeviceSettingLimits
csOn, rise 0.15 MPa, adiabatic efficiency 0.80Bypass closed; 10000000 Nm³/h, 100000 kW, ratio about 98.69
controlValve_br65Open, outlet 3.163675 MPagCheck pressure and flow

Compressor rise is across device ports. Regulator target is the adapted downstream allowable-range midpoint. Check each target against its own ports.

Simulation Settings​

SettingValue
Simulation / thermalSteady-state / isothermal
Temperature16 °C
EOS / gasAGA8Gross / GasLibGas
Standard state101.325 kPa(a), 0 °C
Gauge reference101.325 kPa(a)
Long-pipe solveFDM, production steady startup

GasLibGas has relative density 0.573787, CO₂ 0 mole%, gross heating value 39.82 MJ/Nm³ at the table standard state. Ports remain 16 °C; power follows adiabatic compression. Gas and References

Steady State Calculation Results and Analysis​

DeviceInlet MPagOutlet MPagChange kPaNm³/hState
cs5.132845.28284+150.00341951.23Active; 326.66 kW
Regulator3.988243.163675−824.5685312.79Outlet regulated

Change is outlet minus inlet. Compressor reaches 0.15 MPa with absolute ratio about 1.02866 and zero bypass. Regulator reaches target. Source flows 82197.50 and 319351.85 sum to demand 401549.35 Nm³/h.

Check global totals separately from local closure: sum source/load flow, then inspect junction pressures and direction-aware mass balances.

Simulation Capabilities Reflected in Calculation Examples​

CapabilityApplication
Large networkJoint solve of nodes, 86 pipes, boundaries/devices
Distributed pipesFDM for 78 longer pipes
Multiple sourcesFlow plus pressure slack allocation
Multiple loads45 boundaries and concentrated-demand effects
CompressionRise, flow, bypass, ratio, power
RegulationDownstream pressure and valve flow
VerificationTotals, nodes, pressure closure, residuals

Results Viewing Process​

  1. Open GasLib-134 medium-load compression, select completed steady job, and inspect residuals.
  2. Find sources and major loads; compare specified and solved quantities.
  3. Check cs rise, flows, power, and regulator target.
  4. Sum supply/demand and sample junction pressure/mass closure.

See Run and View Results for jobs and blocks.

Extended Comparison Conditions​

ComparisonChangeCheckPurpose
DemandQ10/Q90Allocation, minimum pressure, flow/powerLoad sensitivity
Bypasscs bypassPressure and allocationBoosting feasibility
Risecs targetDischarge, power, downstreamEnergy/pressure comparison
Slacknode_20 pressureSlack flow, network pressuresSupply sensitivity
RegulationValve targetFlow, downstream, allocationZone effect
Major demandIncrease node_ld42 or anotherMinimum pressure, trunk, marginCapacity effects

When comparing extended working conditions, only change one boundary, equipment setting or load scenario at a time, and keep the rest of the adaptation strategies consistent. Comparative working conditions without actual calculation are only used as follow-up analysis plans and are not regarded as the established conclusion of this benchmark working condition.