GasLib-134 Standard Pipeline Network Medium Load Compression Operation
Based on GasLib-134 Q50 medium demand, this steady network has 134 nodes, 3 sources, 45 loads, a compressor, and a regulator. Check source allocation, load pressures, active boosting, regulation, and node conservation alongside equipment state.
Study Overview
| Item | Configuration |
|---|---|
| Scenario | Q50, 2012-08-28 |
| Network | 134 nodes, 3 sources, 45 loads, 86 pipes, 1 compressor, 1 regulator |
| Analysis | Steady-state, isothermal |
| Supply/demand | 401549.35 Nm³/h each; 2 nonzero sources, 33 nonzero loads |
| Devices | cs active 0.15 MPa rise; controlValve_br65 outlet pressure control |
| Checks | Allocation, pressure/flow, power, states, conservation, pressure closure |
| Scope | Large-network validation and interpretation |
Working Conditions Background and Pipe Network Structure
Working Condition Background
Large networks combine sources, offtakes, loops, and trees. Pressure slack supply balances specified loads; compression and regulation maintain local conditions. Success also requires boundary, state, conservation, pressure closure, and convergence checks.
This example belongs to the GasLib standard network benchmark that has been adapted to the project. It is used to verify large-scale network modeling and result interpretation methods. It does not represent the compression station selection, pipeline transmission plan or scheduling plan of a specific project.
Pipe Network Structure

Figure: GasLib-134 full network topology overview. This diagram is used to identify the overall shape of the network and the connection relationships between various regions.
Long pipelines connect distributed regions; cs lies on the main path and controlValve_br65 at a downstream zone entry. All boundaries, resistance, and settings determine flow.
Due to the large number of nodes in the entire network, a single overview diagram cannot ensure that the overall structure and component labels are clear at the same time. The following is a partial structure diagram based on the upper left, upper right, middle and lower areas. A small number of overlapping connections are retained between each diagram to facilitate correspondence with the entire network overview.
Upper Left Area

Upper Right Area

Picture: Upper right regional pipe network. The original screenshot is rotated 90° clockwise and placed.
Central Region

Lower Area

Figure: GasLib-134 zoned pipe network structure. The local map is used to identify gas sources, loads, pipelines and equipment labels; node connection relationships are still indexed by the full network overview.
Pipeline Representation and Adaptation Range
| Type | Quantity | Modeling Approach | Description |
|---|---|---|---|
| Long physical pipeline | 78 paragraphs | LongPipe | FDM long pipe hydraulic solution is used; the length of a single section is 3.598~73.190 km |
| Shorter physical pipeline | 8 paragraphs | Pipe | Single section length 0.651~2.915 km |
| GasLib shortPipe | 45 paragraphs | 1 m, DN1000 Pipe | It is used to retain the standard network connection relationship and is not interpreted as an actual pipeline segment. |
The total length of 86 physical pipeline sections is approximately 1447.02 km, of which 78 long pipe sections have a total length of approximately 1433.60 km. The diameter range of long tube is 254~914.4 mm. The 45-segment connecting adapter pipe is not counted in the physical pipe quantity and the total physical pipe length.
Boundary Conditions and Simulation Setup
Air Source and Load Boundaries
| Boundary | Type | Value | Meaning |
|---|---|---|---|
node_1 | Flow source | 82197.50 Nm³/h; 5.40317 MPag solved | Fixed supply |
node_20 | Pressure source | 5.277675 MPag; 319351.85 Nm³/h solved | Slack supply |
node_80 | Zero-flow source | 0; 3.98599 MPag solved | Inactive supply |
| 45 loads | Flow | Total 401549.35 Nm³/h | 33 nonzero, 12 zero |
node_1 and node_20 bear about 20.47% and 79.53% of the total air supply volume respectively. The flow rate of the pressure relaxation gas source is not a predetermined result, but a balanced quantity obtained by the network after all loads, pipeline pressure drops and equipment settings are met.
The load is mainly concentrated on several nodes. The following table lists the seven loads with the largest traffic, which together account for approximately 88.17% of the entire network load.
| Load | Nm³/h | MPag |
|---|---|---|
node_ld42 | 82197.50 | 3.12679 |
node_ld32 | 56043.75 | 3.96764 |
node_ld25 | 56043.75 | 4.07779 |
node_ld27 | 46718.07 | 4.04567 |
node_ld12 | 42970.61 | 5.10336 |
node_ld24 | 37362.50 | 4.07779 |
node_ld31 | 32692.19 | 3.96764 |
Compressor and Regulator Settings
| Device | Setting | Limits |
|---|---|---|
cs | On, rise 0.15 MPa, adiabatic efficiency 0.80 | Bypass closed; 10000000 Nm³/h, 100000 kW, ratio about 98.69 |
controlValve_br65 | Open, outlet 3.163675 MPag | Check pressure and flow |
Compressor rise is across device ports. Regulator target is the adapted downstream allowable-range midpoint. Check each target against its own ports.
Simulation Settings
| Setting | Value |
|---|---|
| Simulation / thermal | Steady-state / isothermal |
| Temperature | 16 °C |
| EOS / gas | AGA8Gross / GasLibGas |
| Standard state | 101.325 kPa(a), 0 °C |
| Gauge reference | 101.325 kPa(a) |
| Long-pipe solve | FDM, production steady startup |
GasLibGas has relative density 0.573787, CO₂ 0 mole%, gross heating value 39.82 MJ/Nm³ at the table standard state. Ports remain 16 °C; power follows adiabatic compression. Gas and References
Steady State Calculation Results and Analysis
| Device | Inlet MPag | Outlet MPag | Change kPa | Nm³/h | State |
|---|---|---|---|---|---|
cs | 5.13284 | 5.28284 | +150.00 | 341951.23 | Active; 326.66 kW |
| Regulator | 3.98824 | 3.163675 | −824.56 | 85312.79 | Outlet regulated |
Change is outlet minus inlet. Compressor reaches 0.15 MPa with absolute ratio about 1.02866 and zero bypass. Regulator reaches target. Source flows 82197.50 and 319351.85 sum to demand 401549.35 Nm³/h.
Check global totals separately from local closure: sum source/load flow, then inspect junction pressures and direction-aware mass balances.
Simulation Capabilities Reflected in Calculation Examples
| Capability | Application |
|---|---|
| Large network | Joint solve of nodes, 86 pipes, boundaries/devices |
| Distributed pipes | FDM for 78 longer pipes |
| Multiple sources | Flow plus pressure slack allocation |
| Multiple loads | 45 boundaries and concentrated-demand effects |
| Compression | Rise, flow, bypass, ratio, power |
| Regulation | Downstream pressure and valve flow |
| Verification | Totals, nodes, pressure closure, residuals |
Results Viewing Process
- Open GasLib-134 medium-load compression, select completed steady job, and inspect residuals.
- Find sources and major loads; compare specified and solved quantities.
- Check
csrise, flows, power, and regulator target. - Sum supply/demand and sample junction pressure/mass closure.
See Run and View Results for jobs and blocks.
Extended Comparison Conditions
| Comparison | Change | Check | Purpose |
|---|---|---|---|
| Demand | Q10/Q90 | Allocation, minimum pressure, flow/power | Load sensitivity |
| Bypass | cs bypass | Pressure and allocation | Boosting feasibility |
| Rise | cs target | Discharge, power, downstream | Energy/pressure comparison |
| Slack | node_20 pressure | Slack flow, network pressures | Supply sensitivity |
| Regulation | Valve target | Flow, downstream, allocation | Zone effect |
| Major demand | Increase node_ld42 or another | Minimum pressure, trunk, margin | Capacity effects |
When comparing extended working conditions, only change one boundary, equipment setting or load scenario at a time, and keep the rest of the adaptation strategies consistent. Comparative working conditions without actual calculation are only used as follow-up analysis plans and are not regarded as the established conclusion of this benchmark working condition.