Skip to main content

Gas Transmission Trunk Intermediate Compression Station Booster

In this example, a 160 km gas transmission trunk line is divided into upstream and downstream sections, and a compressor station is set up in the middle. The gas enters the upstream pipe section from the gas field source. After the pressure is reduced along the way, the pressure is restored at the intermediate compression station, and then transported to the terminal city gate station through the downstream pipe section. The calculation is used to analyze the impact of intermediate boosting on the main line pressure distribution, and to check the compressor's pressure ratio, compression branch flow, bypass status, shaft power and operating margin.

Study Overview​

ProjectContent
Working conditionsThe gas from the gas field is transported to the terminal city gate station through long-distance gas transmission trunk lines and intermediate compression stations.
Pipe network scale1 gas source, 2 sections of 80 km long-distance pipeline, 1 intermediate compression station, 1 end load; total line length 160 km
Analysis typeSteady-state, isothermal gas pipeline network calculations
boundary conditionsThe gas source adopts a 5 MPag pressure boundary; the terminal city gate station adopts a 4.5 MPag pressure boundary
Device controlThe compressor is turned on, using outlet pressure control, and the outlet pressure is set to 6 MPag
Calculate contentTwo-section main line pressure drop, compression station inlet and outlet pressure, pressure ratio, flow rate, bypass status, shaft power and full process pressure closure
Scope of applicationSteady-state working condition analysis of intermediate boosting scheme, transmission capacity check of long-distance trunk line and equipment operation margin analysis
Job statussuccess / 100%

Working Conditions Background and Pipe Network Structure​

Working Condition Background​

During long-distance gas transmission, pipeline friction will continue to reduce pressure along the transportation direction. When the upstream air supply pressure is insufficient to simultaneously overcome the resistance of the entire line and maintain the terminal delivery pressure, a compression station can be set up in the middle of the main line to restore the pressure. This example uses the specified gas source pressure and terminal delivery pressure as boundaries to calculate the steady-state gas delivery volume and equipment load when the intermediate compression station operates at an outlet pressure of 6 MPag.

Pipe Network Structure​

Gas transmission trunk intermediate compressor station model in NexusFlow gas pipeline network simulation platform
Gas transmission trunk intermediate compressor station model in NexusFlow gas pipeline network simulation platform

The models are connected in order according to the gas flow direction as:

Gas Field → 80 km Upstream Pipeline → Compressor Station → 80 km Downstream Pipeline → City Gate

The intermediate compression station is represented by a common compressor component, focusing on retaining outlet pressure control, compression branch, bypass branch and equipment operation restrictions. The model does not expand the parallel connection of multiple units in the station, coolers, separators, valve groups and station manifolds.

Long-Distance Pipeline Parameters​

Pipe SectionLengthInner DiameterWall ThicknessAbsolute RoughnessNumber of GridsFriction Model
Upstream long pipe80 km500 mm10 mm0.025 mm10Colebrook
Downstream long pipe80 km500 mm10 mm0.025 mm10Colebrook

Both sections of the pipeline adopt the Colebrook friction model and explicit solution method, and the inlet and outlet elevations are both 0 m. This example does not consider the impact of terrain height difference on pressure distribution.

Intermediate Compression Station Configuration​

SettingValue
StateOn
TargetOutlet pressure 6 MPag
Process / efficiencyAdiabatic / 0.82
Standard-flow maximumEnabled, 500000 Nm³/h
Shaft-power maximumEnabled, 10000 kW
Ratio maximumEnabled, 8
BypassClosed

Boundary Conditions and Simulation Setup​

Air Source and Load Boundaries​

CategoryLabelBoundary Configuration
Air sourceGas field gas sourcePressure boundary; 5 MPag; 20 ℃
loadterminal city gate stationPressure boundary; 4.5 MPag

Both the gas source and the terminal adopt pressure boundaries, so this example calculates the steady-state delivery capacity under the specified gas supply pressure, terminal delivery pressure and compressor station outlet pressure, and the flow rate is not a predetermined value.

Compressor Control Settings​

The fixed outlet request is 6 MPag. Confirm active compression using both pressures, compression/bypass flow, shaft power, and hydraulic mode.

Simulation Settings​

SettingValue
Simulation / thermalSteady-state / isothermal
Temperature20 °C
EOS / gasBWRS / NaturalGas
Gauge reference101.325 kPa(a)
Standard state101.325 kPa(a), 20 °C

NaturalGas mole percentages are methane 90, ethane 5, propane 2, nitrogen 2, CO₂ 1. Ports stay 20 °C; power follows adiabatic process and efficiency. General Compressor

Steady State Calculation Results and Analysis​

SectionInlet MPagOutlet MPagChange MPaNm³/h
Upstream5.000002.98321−2.01679263597.42
Compressor2.983216.00000+3.01679263597.42
Downstream6.000004.50000−1.50000263597.42

Outlet-minus-inlet changes close: pipes lose 3.51679 MPa, compressor restores 3.01679, net loss 0.50000. Outlet reaches 6 MPag; all flow uses compression, bypass zero.

CheckResultLimit
Nm³/h263597.42500000
Shaft kW6401.9410000
Absolute ratio1.9788

Ratio uses absolute pressures. Power margin is 3598.06 kW; none of the three limits governs this point.

Simulation Capabilities Reflected in Calculation Examples​

Simulation ContentApplication in This Example
Hydraulic calculation of long-distance gas pipeline networkCalculate the steady-state transport flow and segmental pressure drop of the 160 km trunk line based on the pressure boundaries at both ends
Constant pressure at the outlet of the intermediate compression stationCalculate pressure rise, pressure ratio and shaft power required to maintain 6 MPag outlet pressure
Compression and bypass status discriminationDetermine the actual status of the equipment through compression branch flow, bypass flow, shaft power and hydraulic operation mode
Device Limitation CheckCompare calculated flow, shaft power and pressure ratio to equipment upper limit
Full process pressure closureCheck the relationship between the pressure drop of the two sections of pipeline, the pressure rise of the compression station and the boundary pressure
Traffic continuity checkCompare standard volumetric flow rates for sources, pipe sections, compressors, and loads

Results Viewing Process​

  1. Open the midpoint compression example and completed steady job.
  2. Create a compressor data block; check pressures, rise, ratio, path flows, and power.
  3. Check both pipes; use Pressure Profile for within-pipe distance results.
  4. Compare tables and limits; inspect steady residuals if needed.

See Run and View Results for workbench operations.

Extended Comparison Conditions​

Compare Working ConditionsModify ContentKey Comparison ResultsEngineering Purposes
Outlet pressure setting adjustmentIndividually change the compressor outlet pressure setpointPressure ratio, shaft power, conveying flow rate and terminal pressure conditionsAnalyze the impact of outlet pressure targets on energy consumption and delivery capacity
Upstream supply pressure decreasesIndividually reduce gas field gas source pressureCompressor inlet pressure, pressure ratio, shaft power and operating limitationsAssessing intermediate station boosting requirements at low air supply pressures
Increased pressure on terminal deliveryIndividually increase the end city gate station pressure boundaryDownstream segment flow, compressor load and pressure marginCheck gas supply capacity at higher delivery pressure
Pipe section resistance changesIndividually change the diameter, length or roughness of a section of pipeStage pressure drop, compressor inlet pressure and delivery flowCompare the impact of pipe modifications or resistance growth on the system
Bypass controlKeeping other conditions constant, change compressor operation or bypass configurationCompression branch flow, bypass flow, terminal pressure and delivery capacityDistinguish between active compression and bypass operating conditions
Device capability boundariesIndividually adjust maximum flow, maximum power or maximum pressure ratioLimit trigger status, achievable outlet pressure, and steady-state flowAnalyze the operable range under the constraints of equipment capabilities

When performing extended case comparisons, change only one boundary, equipment setting, or pipeline parameter at a time, while keeping other conditions consistent. Comparative working conditions without actual calculation are only used as follow-up analysis plans and are not regarded as the established conclusion of this benchmark working condition.