Gas Transmission Trunk Intermediate Compression Station Booster
In this example, a 160 km gas transmission trunk line is divided into upstream and downstream sections, and a compressor station is set up in the middle. The gas enters the upstream pipe section from the gas field source. After the pressure is reduced along the way, the pressure is restored at the intermediate compression station, and then transported to the terminal city gate station through the downstream pipe section. The calculation is used to analyze the impact of intermediate boosting on the main line pressure distribution, and to check the compressor's pressure ratio, compression branch flow, bypass status, shaft power and operating margin.
Study Overview
| Project | Content |
|---|---|
| Working conditions | The gas from the gas field is transported to the terminal city gate station through long-distance gas transmission trunk lines and intermediate compression stations. |
| Pipe network scale | 1 gas source, 2 sections of 80 km long-distance pipeline, 1 intermediate compression station, 1 end load; total line length 160 km |
| Analysis type | Steady-state, isothermal gas pipeline network calculations |
| boundary conditions | The gas source adopts a 5 MPag pressure boundary; the terminal city gate station adopts a 4.5 MPag pressure boundary |
| Device control | The compressor is turned on, using outlet pressure control, and the outlet pressure is set to 6 MPag |
| Calculate content | Two-section main line pressure drop, compression station inlet and outlet pressure, pressure ratio, flow rate, bypass status, shaft power and full process pressure closure |
| Scope of application | Steady-state working condition analysis of intermediate boosting scheme, transmission capacity check of long-distance trunk line and equipment operation margin analysis |
| Job status | success / 100% |
Working Conditions Background and Pipe Network Structure
Working Condition Background
During long-distance gas transmission, pipeline friction will continue to reduce pressure along the transportation direction. When the upstream air supply pressure is insufficient to simultaneously overcome the resistance of the entire line and maintain the terminal delivery pressure, a compression station can be set up in the middle of the main line to restore the pressure. This example uses the specified gas source pressure and terminal delivery pressure as boundaries to calculate the steady-state gas delivery volume and equipment load when the intermediate compression station operates at an outlet pressure of 6 MPag.
Pipe Network Structure

The models are connected in order according to the gas flow direction as:
Gas Field → 80 km Upstream Pipeline → Compressor Station → 80 km Downstream Pipeline → City Gate
The intermediate compression station is represented by a common compressor component, focusing on retaining outlet pressure control, compression branch, bypass branch and equipment operation restrictions. The model does not expand the parallel connection of multiple units in the station, coolers, separators, valve groups and station manifolds.
Long-Distance Pipeline Parameters
| Pipe Section | Length | Inner Diameter | Wall Thickness | Absolute Roughness | Number of Grids | Friction Model |
|---|---|---|---|---|---|---|
| Upstream long pipe | 80 km | 500 mm | 10 mm | 0.025 mm | 10 | Colebrook |
| Downstream long pipe | 80 km | 500 mm | 10 mm | 0.025 mm | 10 | Colebrook |
Both sections of the pipeline adopt the Colebrook friction model and explicit solution method, and the inlet and outlet elevations are both 0 m. This example does not consider the impact of terrain height difference on pressure distribution.
Intermediate Compression Station Configuration
| Setting | Value |
|---|---|
| State | On |
| Target | Outlet pressure 6 MPag |
| Process / efficiency | Adiabatic / 0.82 |
| Standard-flow maximum | Enabled, 500000 Nm³/h |
| Shaft-power maximum | Enabled, 10000 kW |
| Ratio maximum | Enabled, 8 |
| Bypass | Closed |
Boundary Conditions and Simulation Setup
Air Source and Load Boundaries
| Category | Label | Boundary Configuration |
|---|---|---|
| Air source | Gas field gas source | Pressure boundary; 5 MPag; 20 ℃ |
| load | terminal city gate station | Pressure boundary; 4.5 MPag |
Both the gas source and the terminal adopt pressure boundaries, so this example calculates the steady-state delivery capacity under the specified gas supply pressure, terminal delivery pressure and compressor station outlet pressure, and the flow rate is not a predetermined value.
Compressor Control Settings
The fixed outlet request is 6 MPag. Confirm active compression using both pressures, compression/bypass flow, shaft power, and hydraulic mode.
Simulation Settings
| Setting | Value |
|---|---|
| Simulation / thermal | Steady-state / isothermal |
| Temperature | 20 °C |
| EOS / gas | BWRS / NaturalGas |
| Gauge reference | 101.325 kPa(a) |
| Standard state | 101.325 kPa(a), 20 °C |
NaturalGas mole percentages are methane 90, ethane 5, propane 2, nitrogen 2, CO₂ 1. Ports stay 20 °C; power follows adiabatic process and efficiency. General Compressor
Steady State Calculation Results and Analysis
| Section | Inlet MPag | Outlet MPag | Change MPa | Nm³/h |
|---|---|---|---|---|
| Upstream | 5.00000 | 2.98321 | −2.01679 | 263597.42 |
| Compressor | 2.98321 | 6.00000 | +3.01679 | 263597.42 |
| Downstream | 6.00000 | 4.50000 | −1.50000 | 263597.42 |
Outlet-minus-inlet changes close: pipes lose 3.51679 MPa, compressor restores 3.01679, net loss 0.50000. Outlet reaches 6 MPag; all flow uses compression, bypass zero.
| Check | Result | Limit |
|---|---|---|
| Nm³/h | 263597.42 | 500000 |
| Shaft kW | 6401.94 | 10000 |
| Absolute ratio | 1.978 | 8 |
Ratio uses absolute pressures. Power margin is 3598.06 kW; none of the three limits governs this point.
Simulation Capabilities Reflected in Calculation Examples
| Simulation Content | Application in This Example |
|---|---|
| Hydraulic calculation of long-distance gas pipeline network | Calculate the steady-state transport flow and segmental pressure drop of the 160 km trunk line based on the pressure boundaries at both ends |
| Constant pressure at the outlet of the intermediate compression station | Calculate pressure rise, pressure ratio and shaft power required to maintain 6 MPag outlet pressure |
| Compression and bypass status discrimination | Determine the actual status of the equipment through compression branch flow, bypass flow, shaft power and hydraulic operation mode |
| Device Limitation Check | Compare calculated flow, shaft power and pressure ratio to equipment upper limit |
| Full process pressure closure | Check the relationship between the pressure drop of the two sections of pipeline, the pressure rise of the compression station and the boundary pressure |
| Traffic continuity check | Compare standard volumetric flow rates for sources, pipe sections, compressors, and loads |
Results Viewing Process
- Open the midpoint compression example and completed steady job.
- Create a compressor data block; check pressures, rise, ratio, path flows, and power.
- Check both pipes; use Pressure Profile for within-pipe distance results.
- Compare tables and limits; inspect steady residuals if needed.
See Run and View Results for workbench operations.
Extended Comparison Conditions
| Compare Working Conditions | Modify Content | Key Comparison Results | Engineering Purposes |
|---|---|---|---|
| Outlet pressure setting adjustment | Individually change the compressor outlet pressure setpoint | Pressure ratio, shaft power, conveying flow rate and terminal pressure conditions | Analyze the impact of outlet pressure targets on energy consumption and delivery capacity |
| Upstream supply pressure decreases | Individually reduce gas field gas source pressure | Compressor inlet pressure, pressure ratio, shaft power and operating limitations | Assessing intermediate station boosting requirements at low air supply pressures |
| Increased pressure on terminal delivery | Individually increase the end city gate station pressure boundary | Downstream segment flow, compressor load and pressure margin | Check gas supply capacity at higher delivery pressure |
| Pipe section resistance changes | Individually change the diameter, length or roughness of a section of pipe | Stage pressure drop, compressor inlet pressure and delivery flow | Compare the impact of pipe modifications or resistance growth on the system |
| Bypass control | Keeping other conditions constant, change compressor operation or bypass configuration | Compression branch flow, bypass flow, terminal pressure and delivery capacity | Distinguish between active compression and bypass operating conditions |
| Device capability boundaries | Individually adjust maximum flow, maximum power or maximum pressure ratio | Limit trigger status, achievable outlet pressure, and steady-state flow | Analyze the operable range under the constraints of equipment capabilities |
When performing extended case comparisons, change only one boundary, equipment setting, or pipeline parameter at a time, while keeping other conditions consistent. Comparative working conditions without actual calculation are only used as follow-up analysis plans and are not regarded as the established conclusion of this benchmark working condition.