Large Gas Storage Gas Injection and Compression Station - Multi-Unit Joint Pressurization
This example shows the Multi-unit parallel splitting, single branch two-stage boosting and multi-outlet gas injection of a large gas storage gas injection station. The model is equipped with 8 two-stage piston compressor units and a booster branch composed of two centrifugal compression stages connected in series. The incoming air and air injection main lines are connected through the station header and valve group.
Load 3 supplies about 7.30 MPa(g). Two centrifugal stages and piston units 4, 6, 8 boost into N-end A/B equally. Total is about 1.0157 million Nm³/h (24.3777 million Nm³/d). TX is standby; S-end injection is zero.
Study Overview
| Item | Configuration/result | Check |
|---|---|---|
| Scenario | Isothermal steady injection | Supply/backpressure operation |
| Equipment | 8 two-stage piston units, 2 centrifugal stages, headers/valves | Configured versus flowing units |
| Supply | Load 3: 1015739.22 Nm³/h; TX: 0 | Actual source |
| Boosting | Centrifugal plus piston 4/6/8 | Load sharing |
| Injection | N A/B: 507869.61 each; S: 0 | Backpressure/path relation |
| Thermal | 20 °C, BWRS | Real-gas hydraulics |
| Results | Balance → stages → split → power → convergence | Station interpretation |
| Scope | Main flow and active units | Separate isolated pressure references |
Working Conditions Background and Site Structure
Gas Injection Operation Job
Gas injection in the gas storage requires increasing the gas from outside the station to the pressure required by the gas injection main line. The inlet pressure, outlet back pressure, unit capacity and station resistance jointly determine the achievable gas injection volume; after multiple units are put into operation, the flow will be redistributed among different booster branches.
Supply about 7.30 MPag enters N-end lines at 24.82 MPag. Compressor discharge must exceed injection boundary pressure to cover downstream losses.
Whole Site Topology

Supply and inlet valves are left, centrifugal/piston branches center, export and injection lines right. Flowing branches are identified in results.
Main Gas Transmission Routes
| Path | Process and Function |
|---|---|
| main air supply path | Manifold 3 → Incoming gas connecting pipe section and inlet manifold → Each booster branch |
| Centrifugal booster branch | Centrifugal compressor - first stage → interstage connection and check component → centrifugal compressor - second stage → outlet header |
| Piston booster branch | Unit inlet → first level of the unit → inter-stage connection → second level of the unit → outlet header; branches of each unit are connected in parallel |
| N-terminal gas injection path | Outbound pipeline and valve group → Section A and Section B of the N-end gas injection trunk line |
| Other connections | Air comes from the TX line, air goes to the TX line after supercharging, air injection at the S end, and branches such as venting and leakage; the actual flow status needs to be checked with the results. |
Some valves and connection components are omitted in the table, and the complete connection relationship is subject to the model.
Series Boosting and Parallel Shunting
The two stages in a single booster branch are connected in series to bear the continuous pressure rise. The same gas passes through the first and second stages in sequence, and is only counted once when counting the branch output; the shaft power of the two stages can be added to represent the shaft power required for compression of the branch.
The centrifugal branch is connected in parallel with multiple piston units to jointly bear the gas injection flow. Each branch is connected to the station header, and its flow rate is affected by unit characteristics, rotation speed, valve status and connection resistance. The two compression stages of the centrifugal branch cannot be repeatedly measured as two independent parallel branches.
Boundary Conditions and Simulation Setup
Simulation Settings and Unit Conventions
| Setting | Value |
|---|---|
| Simulation | Steady-state |
| Thermal | Isothermal, 20 °C |
| EOS | BWRS |
| Gas | Component gas 1, pure methane (CH₄ mole fraction 1) |
| Gauge reference | 101.325 kPa(a) |
| Standard state | 101.325 kPa(a), 20 °C |
| Pressure | MPag = MPa(g) |
| Flow | Standard Nm³/h |
| Ratio | Absolute outlet/inlet |
| Speed | r/min; 1 r/s = 60 r/min |
All data belong to the same steady scenario. Inspect states in blocks and convergence in residuals; recalculate after boundary/unit changes.
Ports remain 20 °C. Piston power follows adiabatic compression; centrifugal points follow maps/network. Non-isothermal cases with appropriate parameters are needed for rise, intercooling, or discharge temperature.
Incoming Gas and Gas Injection Pressure Conditions
| Location | MPa(g) | Role |
|---|---|---|
| TX supply | 1.8987 | Retained low-pressure supply, zero flow |
| Load 3 | 7.2987 | Main source |
| Boosted export to TX | 2.8987 | Zero-flow standby, numerical isolated pressure |
| N A | 24.8187 | Active injection |
| N B | 24.8187 | Active injection |
| S | 25.0387 | Higher-pressure outlet, zero flow |
Supplies/injection outlets use pressure boundaries. TX export uses zero flow on a standby branch. Isolated pressure reference is only for solving that subnetwork.
The S end pressure is 0.22 MPa higher than the N end. The outlet pressure difference will affect the flow distribution together with the branch resistance and valve status; two outlets with the same pressure will not split the flow equally in all working conditions.
Unit Configuration and Current Speed
| Equipment | Configuration/result | Interpretation |
|---|---|---|
| Piston | 8 two-stage units, 16 stages | Not all carry flow |
| Units 4/6/8 | Request 3000 r/min; first actual 2894–2895, second 2744–2745 | Each stage limited to 4000 kW |
| Units 1/2/3/5/7 | Both stages off; zero flow/speed/power | Inactive |
| Centrifugal branch | 2 serial stages | Interstage connection |
| Centrifugal speeds | Both 8856 r/min | Joint boost |
| Valves/checks | Inlet/interstage/outlet/branches | Connectivity and local losses |
Use compression flow, actual speed, and power to identify active boosting. Stopped equipment can have a pressure difference. Interpret isolated pressures with log warnings.
Steady State Calculation Results and Analysis
Station Flow Balance
| Boundary | MPa(g) | Nm³/h |
|---|---|---|
| Load 3 supply | 7.298675 | 1015739.22 |
| TX supply | 1.898675 | 0 |
| N A | 24.818675 | 507869.61 |
| N B | 24.818675 | 507869.61 |
| S | 25.038675 | 0 |
| TX export | Numerical reference | 0 |
A/B total 1015739.22 Nm³/h matches supply. S/TX flows are zero.
Two-Stage Compression and Load Sharing
| Stage | Suction MPag | Discharge MPag | Nm³/h | Shaft kW |
|---|---|---|---|---|
| Piston 4 stage 1 | 7.27356 | 13.58853 | 202996.43 | 4000.00 |
| Piston 4 stage 2 | 13.58853 | 24.90807 | 202996.43 | 4000.00 |
| Centrifugal 1 | 7.27265 | 13.86179 | 406956.05 | 10037.42 |
| Centrifugal 2 | 13.85649 | 24.90366 | 406956.05 | 9485.77 |
| Branch | Nm³/h | Two-stage shaft kW |
|---|---|---|
| Centrifugal | 406956.05 | 19523.19 |
| Piston 4 | 202996.43 | 8000.00 |
| Piston 6 | 202893.37 | 8000.00 |
| Piston 8 | 202893.37 | 8000.00 |
| Total | 1015739.22 | 43523.19 |
Centrifugal supplies 40.07%, pistons 59.93%. Count each serial branch flow once and add stage powers. Centrifugal interstage loss is about 5.30 kPa. All active piston stages reach 4000 kW and stay below requested 3000 r/min.
Isolated-Branch Pressure Reference
Zero-flow TX export lies in an isolated network without a pressure boundary. The solver establishes 2.8987 MPag as numerical reference, with zero flow. Pressure, density, and inventory depend on it; inspect valve paths and physical pressure boundaries before interpreting them.
Results Viewing Process
- Open the station and trace supply, compression, and N injection paths.
- Select completed job; inspect isolated-subnetwork warning and steady residuals.
- Check boundary flows and unit-4/centrifugal stage pressures/powers.
- Compare active piston speeds/power limits and sum branch flow against N A/B.
See Run and View Results for jobs and blocks.
Extended Comparison Conditions
After copying the model, each time you modify one type of condition and solve it again, you can use the results on this page as a comparison point.
| Compare Settings | Key Observations | Analyze Goals |
|---|---|---|
| Change the incoming air pressure of sink 3 | The inlet pressure, pressure ratio, shaft power and gas injection volume of each unit | The influence of incoming air pressure changes on combined supercharging |
| Adjust the N-end or S-end gas injection back pressure | Outlet flow, header pressure and load of each branch | The relationship between gas injection pressure conditions and achievable delivery volume |
| Change the input combination of piston unit | Remaining unit flow, centrifugal branch working status, total gas injection volume | Load redistribution under shared header conditions |
| Changing the operating conditions of the centrifugal branch | Two-stage working point, piston branch branch flow and total shaft power | Operational coordination between different types of equipment |
| Adjust the piston unit speed | Branch flow, interstage pressure and two-stage shaft power | Two-level coordination and volume adjustment effect |
| Adjust valve opening or connect passage | Pressure difference before and after the valve, branch flow and flow direction | Effects of station resistance and channel selection on gas injection distribution |
| Set TX line external output requirements | Output volume, N-end gas injection volume and unit load | Interaction between external transmission and gas storage gas injection jobs |
This example shows isothermal steady-state operation at given boundaries. The gas storage pressure changes with the gas injection time, the unit starts and stops, and the valve switching process requires the configuration of corresponding transient boundaries and control; the analysis of compression temperature rise and cooling load requires a non-isothermal model and supporting thermal parameters.