View and Analyze Simulation Results
After the simulation job is started, Simulation Workbench will continue to receive the status, logs and calculation results generated by the job. The variables and display forms provided by different simulation types may be different, but the viewing entrance and basic operations remain the same.
This page introduces the result analysis method in the order of "selecting jobs - checking logs - viewing key variables - sorting and exporting available data - troubleshooting exceptions".
First Understand Which Job the Result Belongs To
Each time a calculation is started, a separate simulation job is created. Logs, trends, data blocks, monitoring dashboards, and other results belong to the currently selected job and will not change if you later modify the model.
Check three things before viewing the results:
- The left side has been switched to Jobs and the correct job card is selected.
- The job name, creation time and status are consistent with the objectives of this analysis.
- The canvas displays the model that was retained when the job was launched, not the currently editable model.
If "No simulation job has been selected yet" is displayed in the center of the page, you need to select a job from the job list on the left first. How to create, switch and control jobs, please refer to Create and Control Simulation Jobs.
Choose the Appropriate Results Portal
When a job is selected, the results tools appear below the canvas. Each entrance is suitable for solving different problems:
| Entrance | What to Look At | Do I Need to Select Component Before Use? |
|---|---|---|
| Log | Calculation progress, prompts, warnings and errors | No need |
| Trend chart | A curve, table, or grouped result returned by a component | A valid component needs to be selected |
| data block | Display the key values of a component at a certain moment close to the topology | You need to select the target component first and create a data block |
| Dashboard | Gather multiple sets of curves in the current job into a monitoring dashboard | No need to pre-select the component, select the data source when creating the chart |
| Other results | Statistical tables, thematic charts or grouping results that are not directly bound to a component | No need |
| Monitor playback | Play back data block values and component status by time frame | No, but the job must generate monitoring data |
When the result entry displays "No data yet", it does not necessarily mean that the job failed. It may also be that the job has not yet produced this type of result, the current component has no corresponding output, or the simulation type does not provide this type of result. Check the job status and logs first, and then determine whether it is abnormal.
View Calculation Log
Logs are usually the first stop to check whether a job is working properly. Click Logs below the canvas to view the time, level and content of each record.
Filter by Level
The log panel supports the following filter items:
- All: View the complete calculation process by time.
- Info: View general progress and calculation tips.
- Warning: View issues that require attention but do not necessarily cause the job to fail.
- Error: View errors that caused calculation exceptions or incomplete results.
When analyzing jobs, it is recommended to browse "All" to understand the execution sequence, and then filter warning and error respectively. Looking only at the last error may miss earlier parameter or data problems.
Locate Problems Based on Logs
When you see the exception log, you can handle it in the following order:
- Record log time, level and complete content.
- If the log points out a component, use the upper right corner of the canvas to search and locate the component; the multi-sheet model will automatically switch to the sheet where the component is located.
- View the read-only parameters when the component starts calculations in the job canvas to confirm the values actually used by the job.
- Return to model view After fixing the model, save and create a new job validation. Existing jobs will not be recalculated due to model modifications.
The log content is generated by the current simulation type, and the specific wording may be different. If there is only error text but the cause cannot be determined, when reporting to the administrator or model maintainer, please also provide the job name, job status, occurrence time and related component name.
View Trend Graphs for a Single Component
Trend charts are suitable for examining detailed results returned by a component, such as pressure, flow, temperature, opening, or other calculated variables. The actual visible variables are determined by the component and simulation type.
Select Sheet and Component
- Confirm that the target job is currently selected.
- Use the sheet entry in the upper left corner of the canvas to switch to the sheet where the component is located; if you don't know the location, you can use the upper right corner to search.
- Click on a component. Do not select multiple components or wires at the same time.
- Click Trend Chart below the canvas.
If the panel prompts "Please select a valid component", please turn off the multi-select state and confirm that a simulation component in the job canvas is selected, not a data block, auxiliary graphic or connection.

Select Variables to Observe
The trend chart shows the results that the component has produced. The legend is used to control the curve display:
- Click a line segment in the legend to temporarily hide or redisplay the corresponding curve.
- Double-click the legend name to modify the display name in the current job.
- Double-click the legend line segment to adjust the curve color and line width.
Hiding the curve or modifying the legend style only changes the viewing mode, but does not modify the calculation results. When there are many variables, hide the irrelevant curves first, and then check the magnitude, change direction and mutation position of the target variable.
Adjust Time Range
For charts with a continuous horizontal axis, you can use:
- Area Zoom in the chart toolbar, select the interval that needs to be enlarged.
- The range slider below the chart reduces or moves the current display range.
- Right-drag in a zoomed chart to pan the visible range.
- Restore Normal View in the chart toolbar, back to full range.
If the curve looks empty or mutates, first restore the normal view and confirm that the zoom range is not too small or has moved to a no-data interval; then move to the vicinity of the abnormal point and read the specific time and value in conjunction with the prompt box.
View the Original Values in the Chart
Click Data View in the chart toolbar to view the data of the current chart by columns. The time axis is displayed with date and time, making it easy to check curve peaks, missing points or abnormal jumps.
Text in the data view can be selected and copied to a text file or table tool. Click Close to return to the chart; "Refresh" only refreshes the display of the data view and will not rerun the simulation job.
Use Data Blocks to Monitor Key Values
The data block is displayed directly next to the job topology, which is suitable for paying attention to a few key indicators such as inlet pressure, outlet flow, and valve opening at the same time.
Create Data Block
- Find and select the target component in the job canvas.
- Right-click to open the menu and select Create Data Block.
- The data block will appear on the sheet where the component is located, and point to the target component through a dotted line.
- Drag the data block to a location where it does not obscure the topology.

The same component can only create one data block in the current job. If there is no "Create Data Block" in the right-click menu, please confirm that you are currently in the job view, the selected component is a valid component, and check whether the component already has a data block.
Select Display Variables
After clicking the data block, the "Parameters" tab on the right will list the monitoring items provided by the job for the data block. Enable the variables that need to be viewed, disable the variables that are not needed, and the data block will update the display content accordingly.
Variable names and units are provided by the job results. If the data block has been created but only has "no data yet", first confirm whether the job has generated a monitoring frame, and then check whether there is any abnormal result output in the log.
Adjust and Delete Data Blocks
The data block can be moved and resized, and the text size can also be adjusted in the "Format" tab on the right. When confirming that it is no longer needed, select the data block and press Delete, or select Delete from the right-click menu.
The data block belongs to the result viewing configuration of the current job and will not be written back to the editable model or change the calculation process.
Use Dashboard to Combine Sets of Curves
Dashboard at the bottom of the canvas is the entrance to the monitoring dashboard, which is suitable for observing multiple components, multiple result sources or multiple sets of variables in the same panel.
Create Chart
- Click Dashboard to open the floating panel.
- Click Add Chart in the upper right corner of the panel.
- Select chart type: Ordinary Trend Chart or Time Series Two-Dimensional Curve.
- If you select the time series two-dimensional curve, select the Overlay or Expand merging method.
- Search by title in "Select Data Source", expand the result items and check the required curves.
- Fill in the chart title as needed and click Create.
"Overlay" will retain the original horizontal axes of each data source, which is suitable for comparing curves within the same time or location range; "Extend" will splice the horizontal axes in order, suitable for continuous sections. When using extended mode, you can create multiple curve groups and adjust the splicing order of data sources.

Organize Your Dashboard
After you create a chart, you can:
- Drag the chart card to adjust its position.
- Drag the edges of the card to resize.
- Edit the chart and reselect the data source, curve, or title.
- Delete charts that are no longer needed.
- Use the legend to hide curves, modify names, colors and line widths.
- Drag or resize the entire Dashboard floating panel.

Dashboard configuration belongs to the current job. When the units, horizontal axis meanings, or sampling methods are inconsistent between curves, do not make a direct comparison based on shape alone; you should first check the chart title, legend, units, and original values in the data view.
View Other Results
Click Other Results to view job output that is not directly bound to a component, such as summary tables, thematic charts, or combined results containing multiple tabs.

"Other Results" is a draggable, resizable floating panel. What is displayed in the panel is determined by the current simulation type:
- Charts can use area zoom, return to normal view, legend and data view.
- The table is read-only and cells can be selected and copied to the table tool.
- The grouped results are switched through the tabs in the panel.
When the panel displays "No data yet", it means that the current job has not produced any content that can be placed in "Other results". It does not mean that logs, component trends or monitoring data are also empty.
Use Monitoring Playback to View Time Changes
After the job generates monitoring data, the available Monitor Playback control will appear below the canvas. It updates data block values by data frame; if the job also provides component status data, it also updates component graphics, such as switch status or flow direction display.

How to use:
- Click the play button to automatically play back from the current frame.
- Click again to pause.
- Drag the slider to jump to the specified frame; hover to view the time for that frame.
- Observe the data block values and component status changes in the current sheet.
"Current frame/total number of frames" will be displayed on the right side of the control. While the job is still running, new monitoring frames will continue to be added; if it currently stays at the latest frame, the view will follow the latest data.
The range scaling of monitoring playback and trend chart has different purposes: playback controls the frame at which the data block and component status are displayed, while trend chart scaling only changes the visible range of the curve.
Reuse the Result Display Configuration of Other Jobs
When the current model has multiple jobs, you can click Load Other Job Configurations, select another job and click Load. This operation will attempt to copy the data block, Dashboard layout, and legend display configuration. It will not copy the calculation data of another job to the current job.
Only when the corresponding component and result data still exist in the current job, the loaded configuration can be displayed normally. For the method of cross-job working condition comparison, please refer to Compare Simulation Results. This page will not be expanded.
Copy or Export Available Results
There is currently no "Export all job results with one click" button in the general results interface. The following methods can be used depending on the result type:
- Curve Value: Open the chart's Data View, select and copy the text.
- Result Table: Select the required cells, copy them, and then paste them into the table tool.
- Job Canvas: Open the right-click menu in a blank space of the canvas, select Export to SVG, and save the visual content of the current sheet. This file is not a complete mission data package.
- Topic Results: If a certain topic result itself provides a download or export entrance, follow the instructions on the result page; not all jobs will be provided.
Before copying or exporting, it is recommended to note the job name, creation time, workspace type, sheet name, variables and units in the record to avoid losing context after the file leaves the platform.
How to Check When the Results Are Abnormal
When encountering blanks, curve mutations, abnormal values or incomplete results, you can check in the following order:
- Confirm the Job. Check the current job name, status and creation time to avoid viewing other working conditions.
- Check the Logs. first looks at "all", then filters
warninganderror, and records the earliest exception. - Confirm the Sheet and Object. Use search to locate the target component and ensure that only one valid component is selected in the trend chart.
- Restore Display Range. Click "Restore Normal View" in the trend chart to jump back to the frame with data in the monitoring playback.
- Check the Original Value. Use the data view or results table to confirm whether the anomaly is coming from the data itself or simply caused by the legend, scaling, or unit understanding.
- Check the Job Snapshot. Check the read-only parameters in the job canvas to confirm that the calculation is not using model values that have been modified later.
- Recalculate Verification. Return to the model view to correct the problem, save the model and create a new job; do not treat the old job results as recalculated results.
If the results of a historical job originally existed, but are incomplete when reopened, the problem may be related to local data, server records, or the results retention period, see Restore Jobs and Understand Result Retention.
Next Steps
- If you need to compare multiple working conditions, please read Compare Simulation Results.
- To understand the jobs and results after closing the page, please read Restore Jobs and Understand Result Retention.
- To pause, resume or stop a job, please read Create and Control Simulation Jobs.