Skip to main content

Troubleshooting and Frequently Asked Questions

When you encounter a problem, don't click the button repeatedly, and don't clear your browser cache or site data as the first step. The model being edited should be saved first; if the problem is related to a job, the job ID should be noted first. Once the local job record in the browser is cleared, it may not be restored.

This page is used to help you quickly determine which layer the problem is on and prepare enough information to hand over to the administrator. For complete operating instructions of each function, please go to the corresponding special page to view.

First Confirm the Account, Space, Model and Job​

Many seemingly identical problems actually occur on different objects. Before starting the troubleshooting, please confirm the following information:

ObjectWhat Needs to Be ConfirmedCommon Misunderstandings
Account numberWhether the currently logged in user name or complete email, organization, and account are still validAnother account is used, or the account has switched organizations.
workspaceWhich Simulation Workbench you are currently entering and from which entrance?Find or import models in mismatched workspaces
modelModel name and ID, model source, owner, whether the model is currently saved or an unsaved draftTreat shared models as your own editable models, or hidden by search criteria
JobJob name and ID, creation time, current statusViewed another job, or regarded model verification failure as a job running failure

The account password is not troubleshooting information and should not be sent to anyone.

Look at the Page Prompts and Logs Again​

After confirming the object, narrow the scope in the following order:

  1. Log the full prompt on the page, don't just log "Operation failed."
  2. If a job is involved, first confirm whether the job has been created, and then check the first warning or error corresponding to the time of this operation. The end of the log may just be a follow-up phenomenon caused by the previous error.
  3. Try again without modifying the model and parameters, and record the exact time. Do not click Start, Pause, Stop or Save continuously.
  4. Determine the scope of impact: only one model and one account have a problem, or does the same phenomenon occur in multiple models and multiple accounts?
  5. If the input, connection, filter condition or permission can be located, correct this item first; if multiple users are abnormal at the same time, the status does not change for a long time, or the log is inaccessible, let the administrator handle it.

Login Failed or Insufficient Permissions​

Unable to Log in or Repeatedly Returned to the Login Page​

Shortest troubleshooting path:

  1. Confirm that you are using the user name or the complete email address that has been bound, re-enter the password, and pay attention to the capitalization and input method status.
  2. Reopen the login page from the official platform entrance and exclude invalid old pages or favorite addresses.
  3. Confirm that the network can access the platform normally and try again only once.
  4. According to the page prompts, determine whether the credentials are incorrect, the account is deactivated or expired, or the login status is invalid.

If you still cannot log in, please submit to the administrator: username or email, organization, failure time, platform entrance address, complete prompts and screenshots. Do not submit your password.

See Logging in and Finding Your Way Around for more instructions.

No Menu or Workbench Access Visible​

Shortest troubleshooting path:

  1. Confirm whether the current account and organization are correct.
  2. Please confirm with organization members whether the entrance is only open to specific roles or authorized members.
  3. When the permissions have just been adjusted, refresh the page; if it still does not take effect, log out and log in again.

If other members in the same role can see it but you cannot, please submit: account, organization, missing portal name, expected role, permission adjustment time and screenshot of the current page.

Can'T See a Model​

Shortest troubleshooting path:

  1. Clear the name, type, or visibility filters in the model list.
  2. Confirm that you are viewing the correct personal model listing or Model Marketplace.
  3. Verify that the model owner has modified the visibility and that you are still part of the organization.
  4. Confirm that the current workspace is consistent with the model type.

If the model owner can still see the model, please submit: model name and ID, owner, visibility, your account and organization, current workspace, and a screenshot of the list. See Share Models and Collaborate for sharing rules.

Model Cannot Be Opened, Saved or Imported​

Model Cannot Be Opened​

Shortest troubleshooting path:

  1. Confirm that the model belongs to the current workspace and reopen it from the model list.
  2. If the model comes from the Model Marketplace, first confirm whether it can be opened read-only; if it needs to be modified, it should be saved to a personal model.
  3. Note the first prompt that appears during the loading process, and do not continue to save or start jobs while the page is not fully loaded.
  4. Open another model in the same workspace to determine whether the problem only affects the current model.

When only one model fails, please submit the model name and ID, source, workspace and loading prompt; when multiple models fail, the account number, occurrence time and browser version should also be provided.

Model Saving Failed​

Shortest troubleshooting path:

  1. Confirm that the login status is valid, the network is normal, and check whether the model name meets the page requirements.
  2. Confirm whether the current model is editable. Shared models are usually read-only and require "Save As".
  3. After saving, check the success prompt and whether the unsaved status on the page disappears.
  4. If it fails, keep the current page and do not refresh or close it; log the error first and try "Save As" again.

If it still fails, please submit the model name and ID, the model source, a complete prompt when saving or saving as, when it occurred, and whether only that model was affected. See Create, Open, and Save Models for detailed operations.

Model Import Fails or Exception Occurs After Importing​

Shortest troubleshooting path:

  1. Use the original ZIP file exported by the platform and do not unzip, rezip, or manually modify the files within it.
  2. Confirm that the current workspace is consistent with the type of the exported model.
  3. Record import prompts; if component definition is missing, port exceptions or parameters are incompatible, do not continue to save or start the job.
  4. After the import is successful, first check the topology and parameters, and then save it as a personal model; the import itself does not mean that the model has been saved.

When requiring administrator assistance, please retain the original ZIP and submit the export source, export time, target workspace, import prompt, and exception component name. Submit a model package only if you confirm that the files can be shared safely and the administrator explicitly requires it. See Import, Export, and Copy Models for more instructions.

Component, Connection and Parameter Verification Exceptions​

The Required Component Cannot Be Found​

Shortest troubleshooting path:

  1. Clear the component search term, expand the corresponding category and search again.
  2. Confirm whether the current workspace provides this type of component.
  3. If you are importing a model, check whether the page prompts that the component definition is missing or the version is incompatible.
  4. Use the same account to create a new blank model and determine whether the component library is also missing.

If it is still not found, please submit the component name, expected category, workspace, model source, search result screenshot, and whether it is also missing in the blank model.

Component Cannot Connect​

Shortest troubleshooting path:

  1. Confirm that the connection target is highlighted: the target can be a port or an existing connection that the current workspace supports branch access.
  2. Check whether the port types at both ends are compatible and whether the target port is occupied.
  3. Determine whether the connection is allowed according to the topology rules of the current workspace, and exclude the component from connecting itself. The visual crossing of two lines does not indicate that a connection has been established.
  4. Adjust the component position, reconnect it, and then perform topology verification.

If the page does not give a correctable reason, please submit the starting and ending component names and IDs, the name, type and label of the relevant port, workspace, operation steps and screenshots. See Add Components and Build Model Topology for topology operations.

Parameter Verification Failed​

Shortest troubleshooting path:

  1. Starting from the first verification error, locate the specific component, parameter or connection.
  2. Check the required fields, data type, value range and unit; do not judge the input to be valid just by "existing values" on the interface.
  3. For pop-up window parameters such as tables and objects, confirm that they have been confirmed or saved in the pop-up window so that the modifications will be written into the current draft.
  4. Fields that are enabled after checking condition changes, and global parameters used by the model.
  5. Correct a type of problem and re-verify. Do not change values in multiple places at the same time.

If the verification occurs before starting the job and there are no new jobs in the job list, this means that the model fails the verification, not that the job enters a fault state. If the same verification error occurs in multiple normal models, or it prompts that the specific input cannot be located, please submit a screenshot of the model ID, workspace, first verification error, related components and parameters. See Configure Component and Global Parameters for parameter description.

The Job Does Not Start or the Status Does Not Change for a Long Time​

There Are No New Jobs After Clicking Start​

Shortest troubleshooting path:

  1. Check whether the page stays in the model verification stage and handle the first verification error.
  2. Confirm that the current draft is the version ready to run, and check whether the login status and permissions to start the job are valid.
  3. Open the job list and confirm whether the job is actually generated by the creation time to avoid repeated startup.
  4. When the job is still not generated, record the click time and page log.

The information submitted to the administrator should include: model name and ID, workspace, click time, page prompts, first log, and whether new records appear in the job list.

The Job Is Stopped at Waiting, Pausing or Stopping​

"Waiting", "Pausing" and "Stopping" may all be short-lived transitional states, and it is not appropriate to use a fixed duration to judge exceptions.

Shortest troubleshooting path:

  1. Do not click the control button repeatedly, record the job ID, status and status start time first.
  2. Compare it with the usual time required for similar jobs, and check whether the current log is still being updated.
  3. Refresh the job list once to confirm that the same job is still displayed.
  4. Check to see if other new jobs are stuck in the same state to determine whether it's a single-job issue or a platform-wide issue.

If it significantly exceeds the normal time for similar jobs, the log has not been updated for a long time, or multiple jobs are affected at the same time, please submit the job ID, model ID, creation time, status stay time, the last valid log and the scope of impact. See Simulation Job Status Reference for the meaning of each status.

Job Enters Fault State​

Shortest troubleshooting path:

  1. Save the complete log first and find the first error closest to the failure time.
  2. Determine whether the error clearly points to model inputs, parameters, connections, or solution settings; if possible, correct the model before creating a new job.
  3. If the error points to a resource, runtime environment, or platform service, do not start the same job repeatedly.
  4. Keep failed jobs and do not just submit new job information after re-running.

Please submit the failed job ID, model name and ID, creation and failure times, first error, last healthy log before failure, and whether the same model ran successfully before. See Create and Control Simulation Jobs for the job control method.

The Result Is Empty, the Result Is Expired, or the Local Job Is Lost​

The Job Is Recorded, but the Result Is Empty​

Shortest troubleshooting path:

  1. Confirm that the currently selected job is the target job, and check the job status.
  2. Select a component that actually produces output of that type, and then select the result type.
  3. Reset the trend chart time range or zoom range to prevent data from falling outside the current visible range.
  4. Check the logs to confirm that the job is still running, has not produced this result, or has failed.

"No data yet" does not necessarily mean a job failure, it may also mean that the job has not yet generated data, the current component does not have this type of output, or the result type selection does not match. If you are still unsure, please submit the job ID, status, selected component, result type, time range and log screenshot. See View and Analyze Simulation Results for detailed instructions.

Prompt Result Has Expired​

The retention periods for job records, model snapshots, and result data are not the same. After the result data expires, refreshing the page will not make the results on the server reappear; whether the local data that the browser has received and retained can still be viewed depends on whether the current browser and site data are still there.

Shortest troubleshooting path:

  1. Check the job ID, end time, and page expiration reminder.
  2. Check if a local job in the same browser can also open the result.
  3. Do not clean site data, and do not expect to restore the results of a cleaned server by logging in again.
  4. Important results that can still be viewed are saved in a timely manner in a manner supported by the current page.

To confirm the platform's actual retention policy, please submit the job ID, job end time, time when results were first discovered to be unavailable, and a complete prompt. See Restore Jobs and Understand Result Retention for recovery and retention boundaries.

The Local Job Cannot Be Found After Changing Devices or Browsers​

The local job record and the server job record in the account are not the same data, and will not be automatically synchronized to other devices.

Shortest troubleshooting path:

  1. Go back to the browser, device, and platform address you used to create the job, and open the same model.
  2. Make sure you are not using incognito mode or clearing the site's data.
  3. If you remember the job ID, query the server job record in job management.
  4. Do not continue to clear or overwrite browser data when local records have been cleared.

When querying by the administrator, please submit the job ID, model ID, creation time, original device and browser, original platform address, and whether the device has been changed, incognito mode has been used, or site data has been cleaned. Do not interpret "job records still exist" to mean that model snapshots and complete results can still be restored.

AI Assistant Cannot Connect or Operate​

Shortest troubleshooting path:

  1. Open "AI Control" on the current model page, select at least one authorization, and then enable the connection.
  2. Use the page's most recently generated complete pairing information. Pairing information is valid for 10 minutes and can only be used once; after regeneration, the old information becomes invalid immediately.
  3. Only one active client remains on the same model page. Disconnect the old client first and then pair again.
  4. Verify that the client supports remote MCP Streamable HTTP connections and does not refresh the page, switch models, or switch workspaces during the connection.
  5. When connected but the operation is denied, check the current authorization scope; close the connection, reselect the permissions, and then enable it.
  6. When you want to operate a job, confirm that the job has been loaded into the current page.

If you still cannot connect, please submit: time of occurrence, browser version, client name and version, current model ID, connection status displayed on the page, and error message. Do not submit your account password, complete pairing information, or any session credentials. See Connect an External AI Assistant Through MCP for authorization scope and connection restrictions.

What to Provide When Contacting an Administrator​

Providing complete context once is often faster than sending scattered screenshots over and over again. Suggestions include:

  • Current account, organization and workspace;
  • Model name, model ID, source, and owner;
  • Job name, job ID, creation time and current status;
  • When the problem occurred and indicate the time zone;
  • The shortest steps to reproduce starting from a normal page;
  • Complete prompt for the page, and the first relevant warning or error in the log;
  • Does the problem only affect one model or account, or can it be reproduced by multiple people and models?
  • Operations that have been tried and whether the phenomenon has changed after the operation;
  • Take screenshots of necessary pages, and cover account privacy and session information before taking screenshots.

In the following situations, you should stop trying and contact the administrator as soon as possible: multiple users cannot use the same function at the same time; the job status obviously exceeds the normal duration of similar jobs and the log is no longer updated; a component definition, port or parameter compatibility prompt appears after importing; the page requires clearing browser data but there are still important job records locally; logging in again after the permission adjustment does not take effect.